Water Pumps & Irrigation Pumps

Explore our range of water pumps designed for irrigation, water transfer, pressure boosting, and bore applications. The collection includes centrifugal pumps, booster pumps, irrigation pumps, and pump accessories from trusted brands known for durability and performance. Suitable for residential, commercial, and agricultural systems with reliable operation and easy installation.

Sort
Davey HP 65-06T (100 LPM Max Flow, 300 kPa Max Pressure)

Davey HP45-05T and HP65-06T twin-stage pressure pumps provide automatic clean-water supply for household use, irrigation, water transfer and washing systems. Their Torrium2 controllers start and stop the pumps as water is used.

Both pumps use a 1 1/4" BSP female inlet and deliver through a 1" BSP male Torrium2 outlet.

They handle clean, non-volatile liquids without fibres or solids at water temperatures from 1°C to 50°C.

The supplied Torrium2 controller automatically starts the pump when water pressure falls and stops it when water demand ends. It automatically sets the starting pressure to suit the pump and installation, adapting during very low demand to reduce repeated starts. Its built-in accumulator allows a small amount of water to be drawn before the pump restarts.

The two-stage pump design uses a 304 stainless steel casing and backplate, glass-filled Noryl stage body and glass-filled polycarbonate impellers. The motor shell is marine-grade aluminium with a baked polyester finish.

Loss-of-prime protection stops the pump if its water supply is lost, with automatic retry to check whether water has returned. The controller also provides high-water-temperature and excessive-current cut-outs. The motor has its own automatic-reset thermal overload protection.

Install horizontally on a firm base in a ventilated, weather-protected position with drainage. Fill the pump casing and suction line with water before starting. Suction-lift installations require a foot valve to retain prime. The maximum suction lift is 6m; actual performance depends on the suction pipework and installation.

Each complete pressure system has a 450kPa maximum system pressure limit and uses a 220-240V single-phase, 50Hz supply.

Two-year Davey warranty, subject to its terms.

Davey HP45-05T & HP65-06T Specifications
Davey Torrium2 Controller Specifications
Davey Torrium2 Installation & Operating Instructions

✓ Application
Automatic household water supply, irrigation, water transfer and washing systems.

✓ Warranty
Two-year Davey warranty, subject to its terms.

✓ Model Specifications

HP65-06T
Twin-stage centrifugal pressure pump.
Maximum flow: 100 LPM.
Maximum total head: approximately 32m.
Approximate curve readings:
40 LPM: approximately 30m total head.
60 LPM: approximately 26m total head.
80 LPM: approximately 21m total head.
Pump inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP male thread (through Torrium2).
Motor output power P2: 0.6kW.
Pump casing and backplate: 304 stainless steel. Stage body: glass-filled Noryl.

HP45-05T
Twin-stage centrifugal pressure pump.
Maximum flow: 70 LPM.
Maximum total head: approximately 33m.
Approximate curve readings:
20 LPM: approximately 32m total head.
40 LPM: approximately 29m total head.
60 LPM: approximately 22m total head.
Pump inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP male thread (through Torrium2).
Motor output power P2: 0.55kW.
Pump casing and backplate: 304 stainless steel. Stage body: glass-filled Noryl.

✓ Outlet Connections
Torrium2 provides horizontal and vertical outlets.

✓ Performance
Flow decreases as head increases.
HP shut-off heads and the flow-at-head examples are approximate readings from the 50Hz curves.
Expected flow depends on vertical lift and pipe resistance.

✓ Automatic Control
Torrium2 uses pressure and flow sensors to start the pump when pressure falls and stop it when water demand ends. It normally restarts at approximately 80% of the previous shut-off pressure and adapts the start pressure during very low demand to reduce repeated starts. A built-in spring-loaded accumulator provides a small amount of draw-off water.

✓ Pump & Motor Protection
Loss-of-prime protection stops the pump if its water supply is lost, with automatic retry to check whether water has returned. The controller also provides high-water-temperature and excessive-current cut-outs. The motor has its own automatic-reset thermal overload protection.

✓ Pressure Limits
Maximum system pressure: 450kPa for both complete systems.

✓ Water Supply
Clean, non-volatile liquids without fibres or solids.
Water temperature: 1°C to 50°C.

✓ Installation & Priming
Mounting: two 10mm holes at 140mm centres.
Install horizontally on a firm base in a ventilated, weather-protected position with drainage. Fill the pump casing and suction line with water before starting. Suction-lift installations require a foot valve to retain prime. The maximum suction lift is 6m; actual performance depends on the suction pipework and installation.

✓ Construction
Glass-filled polycarbonate impellers.
303 stainless steel pump shaft.
Ceramic/carbon mechanical seal with nitrile O-rings.
Marine-grade aluminium motor shell with baked polyester finish.
Glass-fibre-reinforced nylon Torrium2 housing.

✓ Electrical Supply
Maximum ambient temperature: 50°C.
220-240V single phase, 50Hz.
Nominal speed: 2850rpm.
Locked-rotor current: 12A for each model.
Permanent split capacitor starting.
Motor enclosure: IP55.
Torrium2 controller enclosure: IP56.
Motor insulation: Class F.
Controller power lead: 2m with Australian three-pin plug.

✓ Electrical & Physical Details

HP65-06T
Input power P1: 0.9kW.
Full-load current: 3.8A.
Overall length: 329mm.
Overall width: 170mm.
Overall height: 328mm.
Net weight: 9kg.

HP45-05T
Input power P1: 0.77kW.
Full-load current: 3.4A.
Overall length: 329mm.
Overall width: 170mm.
Overall height: 328mm.
Net weight: 9kg.

The Davey XP45T is a single-stage jet-assisted pressure pump for household water supply, irrigation, water transfer and washing systems. It delivers up to 45 LPM with a maximum total head of 32m. Actual flow depends on vertical lift and pipe resistance and decreases as head increases.

The pump has a 1" BSP female thread inlet and supplies water through a 1" BSP male Torrium2 system outlet. It is designed for clean, non-volatile liquids without fibres or solids, at water temperatures from 1°C to 50°C.

The supplied Torrium2 controller automatically starts the pump when water pressure falls and stops it when water demand ends. It automatically sets the starting pressure to suit the pump and installation, adapting during very low demand to reduce repeated starts. Its built-in accumulator allows a small amount of water to be drawn before the pump restarts.

Loss-of-prime protection stops the pump if its water supply is lost, with automatic retry to check whether water has returned. The controller also provides high-water-temperature and excessive-current cut-outs. The motor has its own automatic-reset thermal overload protection.

The jet-assisted hydraulic design uses a glass-filled Noryl casing and venturi, an acetal jet and a glass-filled polycarbonate impeller. A ceramic/carbon mechanical seal and nitrile O-rings seal the pump.

Install horizontally on a firm base in a ventilated, weather-protected position with drainage. Fill the pump casing and suction line with water before starting. Suction-lift installations require a foot valve to retain prime. The maximum suction lift is 6m; actual performance depends on the suction pipework and installation.

The complete system has a maximum system pressure of 450kPa. Its 220-240V single-phase motor provides 0.45kW output power from 0.65kW input power.

Two-year Davey warranty, subject to its terms.

Davey XP45T Specifications
Davey Torrium2 Controller Specifications
Davey Torrium2 Installation & Operating Instructions

✓ Application
The Davey XP45T is a single-stage jet-assisted pressure pump for household water supply, irrigation, water transfer and washing systems.

✓ Warranty
Two-year Davey warranty, subject to its terms.

✓ Connections
Pump inlet: 1" BSP female thread.
System outlet through Torrium2: 1" BSP male thread.
Torrium2 provides horizontal and vertical outlet connections.

✓ Performance
Maximum flow: 45 LPM.
Maximum total head: 32m.
Flow decreases as head increases.
Approximate readings from the 50Hz performance curve:
10 LPM: approximately 26m total head.
20 LPM: approximately 23m total head.
30 LPM: approximately 20m total head.
40 LPM: approximately 17m total head.
Expected flow depends on vertical lift and pipe resistance.

✓ Automatic Control
Torrium2 uses pressure and flow sensors to start the pump when pressure falls and stop it when water demand ends. It normally restarts at approximately 80% of the previous shut-off pressure and adapts the start pressure during very low demand to reduce repeated starts. A built-in spring-loaded accumulator provides a small amount of draw-off water.

✓ Pump & Motor Protection
Loss-of-prime protection stops the pump if its water supply is lost, with automatic retry to check whether water has returned. The controller also provides high-water-temperature and excessive-current cut-outs. The motor has its own automatic-reset thermal overload protection.

✓ Pressure Limits
Maximum system pressure: 450kPa.

✓ Water Supply
Water temperature: 1°C to 50°C.

✓ Installation & Priming
Install horizontally on a firm base in a ventilated, weather-protected position with drainage. Fill the pump casing and suction line with water before starting. Suction-lift installations require a foot valve to retain prime. The maximum suction lift is 6m; actual performance depends on the suction pipework and installation.

✓ Construction
Pump casing and venturi/coverplate: glass-filled Noryl.
Jet: acetal.
Impeller: glass-filled polycarbonate.
Pump shaft: 303 stainless steel.
Mechanical seal: ceramic stationary ring and carbon rotating ring.
O-rings: nitrile rubber.
Motor shell: marine-grade aluminium with baked polyester finish.
Torrium2 housing: glass-fibre-reinforced nylon.

✓ Electrical Supply
Maximum ambient temperature: 50°C.
220-240V single phase, 50Hz.
Nominal motor speed: 2850rpm.
Input power P1: 0.65kW.
Motor output power P2: 0.45kW.
Full-load current: 3.0A.
Locked-rotor current: 12A.
Permanent split capacitor starting.
Motor enclosure: IP55.
Motor insulation: Class F.
Torrium2 controller enclosure: IP56.
Controller power lead: 2m with Australian three-pin plug.

✓ Application & Pump Type
Single-stage jet-assisted centrifugal pump for household water supply, irrigation, water transfer and washing systems.
For clean, non-volatile liquids without fibres or solids.

✓ Dimensions & Weight
Overall length: 391mm.
Overall width: 170mm.
Overall height: 370mm.
Net weight: 7.5kg.
Mounting: two 10mm holes at 140mm centres.
Grundfos CMB5-46 Basic BASICLINE Booster (100 LPM Max Flow, 0.9kW)

Grundfos CM boosters provide automatic household and light commercial water supply from clean-water tanks and other suitable water sources. Their fixed-speed multistage design provides pressure for taps, showers and garden irrigation.

CMB 1-36: rated duty 28.3LPM at 23.7m head.
CMB 3-37: rated duty 51.7LPM at 27.7m head.
CMB 5-46: rated duty 78.3LPM at 38.6m head.

The CMB 1-36 and CMB 3-37 have a 1" BSP female inlet.
The CMB 5-46 has a 1 1/4" BSP female inlet.
All three have a 1" BSP male controller outlet.

The controller starts the pump when water use causes pressure to fall below its fixed starting threshold, and stops it when water use ends. The starting threshold cannot be adjusted on the controller. Pressure while the pump runs depends on water flow, inlet pressure and losses through the controller and pipework.

The CMB 1-36 and CMB 3-37 use PM1 controllers with a fixed 150kPa starting threshold.
The CMB 5-46 uses PM1 with a fixed 220kPa starting threshold.

Dry-running protection stops the pump if the controller detects a lack of water. Anti-cycling protection detects repeated starts caused by small leaks and stops the pump with an alarm. Correct the cause and restore the water supply before resetting the controller, as described in the manual.

Rated duty pairs show flow at the stated head; they are not maximum-flow ratings.

Flow decreases as head increases. Choose the pump for the required flow and pressure at the point of use.

Use clean, thin, non-aggressive and non-explosive water without solid particles or fibres, at temperatures from 0°C to 40°C.

These pumps are not self-priming. Fill the pump casing and inlet pipe with clean water before starting, following the installation instructions. Install on a firm, level base in a ventilated position protected from direct sun, rain and frost.

The pump has a cast iron housing, 304 stainless steel impellers and an AVBE shaft seal with EPDM rubber components. The controller includes a non-return valve. The single-phase motor has built-in overload protection.

Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

Grundfos CM Pump Installation & Operating Instructions

Grundfos PM1 Installation & Operating Instructions

✓ Application
Grundfos CM boosters provide automatic household and light commercial water supply from clean-water tanks and other suitable water sources.

✓ Warranty
Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

✓ Model Specifications
CMB 1-36
Rated duty: 28.3LPM at 23.7m head (manufacturer reference at 2900rpm).
Maximum total head: approximately 36m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Fixed start pressure: 150kPa.
Motor output P2: 0.5kW.
Controller: PM1-15.

CMB 3-37
Rated duty: 51.7LPM at 27.7m head (manufacturer reference at 2900rpm).
Maximum total head: approximately 37m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Fixed start pressure: 150kPa.
Motor output P2: 0.5kW.
Controller: PM1-15.

CMB 5-46
Rated duty: 78.3LPM at 38.6m head (manufacturer reference at 2900rpm).
Maximum total head: approximately 48m.
Inlet: 1 1/4" BSP female thread.
System outlet: 1" BSP male thread.
Fixed start pressure: 220kPa.
Motor output P2: 0.9kW.
Controller: PM1-22.

✓ Supplied Equipment & Control
The controller starts the pump when water use causes pressure to fall below its fixed starting threshold, and stops it when water use ends. The starting threshold cannot be adjusted on the controller. Pressure while the pump runs depends on water flow, inlet pressure and losses through the controller and pipework.

✓ Performance
Flow decreases as head increases.
Maximum head is an approximate curve reading, rather than the pressure available at every flow.
Rated duty pairs show flow at the stated head; they are not maximum-flow ratings. Manufacturer reference speed: 2900rpm.

✓ Pressure Limits
Maximum operating pressure: 1000kPa.
Inlet pressure plus pump pressure must remain within this limit.

✓ Water Supply
Use clean, thin, non-aggressive and non-explosive water without solid particles or fibres, at temperatures from 0°C to 40°C.

✓ Protection
Dry-running protection stops the pump if the controller detects a lack of water. Anti-cycling protection detects repeated starts caused by small leaks and stops the pump with an alarm. Correct the cause and restore the water supply before resetting the controller, as described in the manual.

✓ Installation & Priming
These pumps are not self-priming. Fill the pump casing and inlet pipe with clean water before starting, following the installation instructions. Install on a firm, level base in a ventilated position protected from direct sun, rain and frost.

✓ Construction
The pump has a cast iron housing, 304 stainless steel impellers and an AVBE shaft seal with EPDM rubber components. The controller includes a non-return valve. The single-phase motor has built-in overload protection.

✓ Electrical Supply
Pump motor enclosure: IP55.
PM1 controller enclosure: IP65.
Motor insulation: Class F.
Built-in motor protection: TP211.
Cable: 1.5m with Australian plug.
Maximum ambient temperature: 50°C.

✓ Electrical & Physical Details
CMB 1-36
Power supply: 220-230V single phase, 50Hz.
Maximum current consumption: 3.30-3.15A.
Rated motor speed: 2750-2780rpm.
Net weight: 13.3kg.
Manufacturer product number: 97530097.

CMB 3-37
Power supply: 220-230V single phase, 50Hz.
Maximum current consumption: 3.30-3.15A.
Rated motor speed: 2750-2780rpm.
Net weight: 13.4kg.
Manufacturer product number: 97530133.

CMB 5-46
Power supply: 220-240V single phase, 50Hz.
Maximum current consumption: 5.4-5.0A.
Rated motor speed: 2750-2790rpm.
Overall dimensions: 381.5mm long x 137mm wide x 301mm high.
Net weight: 16.5kg.
Manufacturer product number: 97530169.
Grundfos CMB 5-47 Pressure Switch Booster (100 LPM Max Flow, 0.9kW)

Grundfos CM pressure-switch boosters use fixed-speed multistage pumps for household, irrigation, agricultural and light commercial water supply.

CMB 1-36: rated duty 28.3LPM at 24.2m head.
CMB 3-37: rated duty 51.7LPM at 27.4m head.
CMB 5-47: rated duty 78.3LPM at 38.6m head.
CMB 5-56: rated duty 78.3LPM at 46.5m head.
CMB 5-75: rated duty 78.3LPM at 62.4m head.
CMB 10-47: rated duty 166.7LPM at 38m head.

The CMB 1-36 and CMB 3-37 have a 1" BSP female inlet.
The CMB 5-47, CMB 5-56 and CMB 5-75 have a 1 1/4" BSP female inlet.
The CMB 10-47 has a 1 1/2" BSP female inlet.
All six have a 1" BSP male system outlet.

A suitable pressure tank is required and is supplied separately. It stores water under pressure, allowing small amounts of water to be drawn before the pump needs to restart.

Supplied with a pressure switch that automatically starts the pump when water pressure falls and stops it when pressure rises.

Rated duty pairs show flow at the stated head; they are not maximum-flow ratings.

Flow decreases as head increases. Select the pump for the required flow and pressure, allowing for inlet conditions, height differences and losses through fittings and pipework.

Use clean fresh water without solid particles or fibres, at temperatures from 0°C to 60°C.

These pumps are not self-priming. Before starting, fill the pump casing and inlet pipe with clean water, following the installation instructions. Maximum suction lift is 1m at 20°C, including inlet pipe losses. Install in a ventilated, weather-protected position with drainage and protection from frost.

An installer can adjust the start and stop pressures to suit the system, within the pump’s capacity and the pressure tank’s limits.

CMB 1-36, CMB 3-37 and CMB 5-47: 100-500kPa switch start-pressure adjustment range.
CMB 5-56, CMB 5-75 and CMB 10-47: 300-1200kPa switch start-pressure adjustment range.
These are switch adjustment limits, not the pressures the pump can necessarily deliver. The stop pressure must be achievable by the pump and below both its 1000kPa operating limit and the tank’s pressure limit.

The pump housing, impellers and shaft are stainless steel, with polymer diffusers. A pressure switch, pressure gauge, five-way fitting and non-return valve are supplied. The single-phase motor has thermal overload protection.

Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

Grundfos CM Pump Installation & Operating Instructions
Grundfos CM-PS & CM-PT Pressure-Switch Instructions

✓ Application
Grundfos CM pressure-switch boosters use fixed-speed multistage pumps for household, irrigation, agricultural and light commercial water supply.

✓ Warranty
Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

✓ Model Specifications
CMB 1-36
Rated duty: 28.3LPM at 24.2m head (manufacturer reference at 2900rpm).
Maximum pump head: 36m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.5kW.

CMB 3-37
Rated duty: 51.7LPM at 27.4m head (manufacturer reference at 2900rpm).
Maximum pump head: 36.6m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.5kW.

CMB 5-47
Rated duty: 78.3LPM at 38.6m head (manufacturer reference at 2900rpm).
Maximum pump head: 46.6m.
Inlet: 1 1/4" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.9kW.

CMB 5-56
Rated duty: 78.3LPM at 46.5m head (manufacturer reference at 2900rpm).
Maximum pump head: 55.9m.
Inlet: 1 1/4" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 1.3kW.

CMB 5-75
Rated duty: 78.3LPM at 62.4m head (manufacturer reference at 2900rpm).
Maximum pump head: 74.6m.
Inlet: 1 1/4" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 1.7kW.

CMB 10-47
Rated duty: 166.7LPM at 38m head (manufacturer reference at 2900rpm).
Maximum pump head: 46.6m.
Inlet: 1 1/2" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 1.7kW.

✓ Supplied Equipment & Tank Requirements
A suitable pressure tank is required and is supplied separately. It stores water under pressure, allowing small amounts of water to be drawn before the pump needs to restart.
A pressure switch, pressure gauge, five-way fitting and non-return valve are supplied.

✓ Performance
Flow decreases as head increases. Select the pump for the required flow and pressure, allowing for inlet conditions, height differences and losses through fittings and pipework.
Maximum head is not the pressure available at every flow.
Rated duty pairs show flow at the stated head; they are not maximum-flow ratings. Manufacturer reference speed: 2900rpm.

✓ Pressure Limits
Maximum operating pressure: 1000kPa.
Inlet pressure plus pump pressure must remain within this limit.

✓ Water Supply
Use clean fresh water without solid particles or fibres, at temperatures from 0°C to 60°C.

✓ Installation & Priming
These pumps are not self-priming. Before starting, fill the pump casing and inlet pipe with clean water, following the installation instructions. Maximum suction lift is 1m at 20°C, including inlet pipe losses. Install in a ventilated, weather-protected position with drainage and protection from frost.

✓ Control & Adjustment
Supplied with a pressure switch that automatically starts the pump when water pressure falls and stops it when pressure rises. An installer can adjust the start and stop pressures to suit the system, within the pump’s capacity and the pressure tank’s limits.
These are switch adjustment limits, not the pressures the pump can necessarily deliver. The stop pressure must be achievable by the pump and below both its 1000kPa operating limit and the tank’s pressure limit.

CMB 1-36
Switch start-pressure adjustment range: 100-500kPa.
Switch range only; usable settings depend on pump capacity and pump/tank pressure limits.

CMB 3-37
Switch start-pressure adjustment range: 100-500kPa.
Switch range only; usable settings depend on pump capacity and pump/tank pressure limits.

CMB 5-47
Switch start-pressure adjustment range: 100-500kPa.
Switch range only; usable settings depend on pump capacity and pump/tank pressure limits.

CMB 5-56
Switch start-pressure adjustment range: 300-1200kPa.
Switch range only; usable settings depend on pump capacity and pump/tank pressure limits.

CMB 5-75
Switch start-pressure adjustment range: 300-1200kPa.
Switch range only; usable settings depend on pump capacity and pump/tank pressure limits.

CMB 10-47
Switch start-pressure adjustment range: 300-1200kPa.
Switch range only; usable settings depend on pump capacity and pump/tank pressure limits.

✓ Tank Precharge
Tank precharge is the gas pressure in the tank when its water side is depressurised. Set it to 90% of the pump cut-in pressure, following the tank instructions, and recheck it whenever the switch settings change.

✓ Construction
The pump housing, impellers and shaft are stainless steel, with polymer diffusers. The single-phase motor has thermal overload protection.

✓ Electrical Supply
Single-phase 50Hz supply with Australian plug. Refer to each model's voltage rating.
Built-in single-phase motor thermal protection.

✓ Electrical & Physical Details
CMB 1-36
Power supply: 220-240V single phase, 50Hz.
Maximum current consumption: 3.1-2.8A.
Rated motor speed: 2730-2740rpm.
Net weight: 14.4kg.
Manufacturer product number: 98244555.

CMB 3-37
Power supply: 220-240V single phase, 50Hz.
Maximum current consumption: 3.1-2.8A.
Rated motor speed: 2730-2740rpm.
Net weight: 14.4kg.
Manufacturer product number: 98244556.

CMB 5-47
Power supply: 220-240V single phase, 50Hz.
Maximum current consumption: 5.4-5.0A.
Rated motor speed: 2750-2790rpm.
Net weight: 17.2kg.
Manufacturer product number: 98117630.

CMB 5-56
Power supply: 220-240V single phase, 50Hz.
Maximum current consumption: 8.72-8.1A.
Rated motor speed: 2710-2760rpm.
Net weight: 23.5kg.
Manufacturer product number: 98117632.

CMB 5-75
Power supply: 220-230V single phase, 50Hz.
Maximum current consumption: 10.20-9.75A.
Rated motor speed: 2870-2880rpm.
Net weight: 25.5kg.
Manufacturer product number: 98117633.



CMB 10-47
Power supply: 220-230V single phase, 50Hz.
Maximum current consumption: 10.20-9.75A.
Rated motor speed: 2870-2880rpm.
Net weight: 30.9kg.
Manufacturer product number: 98117635.
Grundfos CMB-SP self-priming booster with PM2 controller

Grundfos CMB-SP PM2 boosters use fixed-speed multistage pumps for automatic clean-water supply from tanks and other suitable water sources.

CMB-SP 3-28: rated duty 50LPM at 20.5m head.
Approximately 28m maximum pump head; 0.5kW motor.
CMB-SP 3-37: rated duty 50LPM at 27.7m head.
Approximately 37m maximum pump head; 0.5kW motor.
CMB-SP 3-47: rated duty 50LPM at 34.9m head.
Approximately 47m maximum pump head; 0.5kW motor.
CMB-SP 3-56: rated duty 50LPM at 42.1m head.
Approximately 56m maximum pump head; 0.67kW motor.
CMB-SP 5-28: rated duty 78.3LPM at 22.1m head.
Approximately 28m maximum pump head; 0.5kW motor.
CMB-SP 5-47: rated duty 78.3LPM at 38m head.
Approximately 47m maximum pump head; 0.9kW motor.

Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.

The supplied PM2 pressure manager starts the pump automatically when water is used and stops it when demand ends.

Rated duties are manufacturer flow-and-head reference points at 2900rpm, not maximum-flow ratings. Flow decreases as head increases. Select the pump for the flow and pressure required, allowing for suction lift, pipe friction and height differences.

Use clean fresh water without solid particles or fibres, at temperatures from 0°C to 40°C.

Self-priming does not mean the pump can start dry. Fill the pump casing with clean water through the filling opening before first use, then refit the plug and follow the startup instructions. The standard assembly supports a suction lift of up to 4m, including inlet-pipe losses at 20°C. Keep the suction pipe airtight and the pump close to the water source.

Install on a firm base in a ventilated, weather-protected position, with drainage and protection from frost.

An installer can adjust the starting pressure from 150kPa to 500kPa in 50kPa steps using switches behind the control panel, with the power isolated. This sets when the pump starts; water pressure while it runs depends on the pump and the water being used.

The controller range is wider than the usable range of some pumps. In normal demand control, the pump must be able to provide at least 40kPa above the selected starting pressure, after allowing for inlet conditions.

The pump sleeve, impellers and shaft are stainless steel, with polymer components in the water path. The motor has built-in overload protection, and the pressure manager provides dry-running protection and a non-return valve.

Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

Grundfos CM Booster Self-Priming Product Brochure
Grundfos CM Pump Installation & Operating Instructions
Grundfos PM1 & PM2 Installation & Operating Instructions
Grundfos CMB & CMB-SP PM2 Booster Instructions

✓ Application
Grundfos CMB-SP PM2 boosters use fixed-speed multistage pumps for automatic clean-water supply from tanks and other suitable water sources.

✓ Warranty
Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

✓ Model Specifications
CMB-SP 3-28
Rated duty: 50LPM at 20.5m head (manufacturer reference at 2900rpm).
Maximum pump head: approximately 28m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.5kW.

CMB-SP 3-37
Rated duty: 50LPM at 27.7m head (manufacturer reference at 2900rpm).
Maximum pump head: approximately 37m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.5kW.

CMB-SP 3-47
Rated duty: 50LPM at 34.9m head (manufacturer reference at 2900rpm).
Maximum pump head: approximately 47m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.5kW.

CMB-SP 3-56
Rated duty: 50LPM at 42.1m head (manufacturer reference at 2900rpm).
Maximum pump head: approximately 56m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.67kW.

CMB-SP 5-28
Rated duty: 78.3LPM at 22.1m head (manufacturer reference at 2900rpm).
Maximum pump head: approximately 28m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.5kW.

CMB-SP 5-47
Rated duty: 78.3LPM at 38m head (manufacturer reference at 2900rpm).
Maximum pump head: approximately 47m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.9kW.

✓ Supplied Equipment & Control
The supplied PM2 pressure manager starts the pump automatically when water is used and stops it when demand ends.
No external pressure tank supplied.

✓ Performance
Rated duties are manufacturer flow-and-head reference points at 2900rpm, not maximum-flow ratings. Flow decreases as head increases. Select the pump for the flow and pressure required, allowing for suction lift, pipe friction and height differences.
Maximum heads shown are approximate readings from the manufacturer’s booster curves, not the pressure available at every flow.

✓ Pressure Limits
Maximum system pressure: 1000kPa. Inlet pressure plus pump pressure must stay within this limit.

✓ Water Supply
Use clean fresh water without solid particles or fibres, at temperatures from 0°C to 40°C.

✓ Installation & Priming
Self-priming does not mean the pump can start dry. Fill the pump casing with clean water through the filling opening before first use, then refit the plug and follow the startup instructions. The standard assembly supports a suction lift of up to 4m, including inlet-pipe losses at 20°C. Keep the suction pipe airtight and the pump close to the water source.
Protect the pump and pressure manager from rain, direct sunlight and frost. Follow the supplied instructions for commissioning and pipework arrangement.

✓ Control Settings & Optional Functions
PM2 starting-pressure adjustment range: 150-500kPa, in 50kPa steps.
Usable settings depend on pump capacity and inlet conditions.
An installer can adjust the starting pressure from 150kPa to 500kPa in 50kPa steps using switches behind the control panel, with the power isolated. This sets when the pump starts; water pressure while it runs depends on the pump and the water being used.
The controller range is wider than the usable range of some pumps. In normal demand control, the pump must be able to provide at least 40kPa above the selected starting pressure, after allowing for inlet conditions.
With a suitable separate pressure tank, PM2 also offers a mode that stops the pump 100kPa above its starting pressure. This mode requires the pump to provide at least 140kPa above the starting pressure; the normal demand-control mode can be used without an external tank.
Optional PM2 functions include anti-cycling, automatic alarm reset and a 30-minute continuous-run limit. Enable only the functions suitable for the installation. Automatic reset is for installations with positive inlet pressure.

✓ Construction & Protection
The pump sleeve, impellers and shaft are stainless steel, with polymer components in the water path. The motor has built-in overload protection, and the pressure manager provides dry-running protection and a non-return valve.

✓ Electrical Supply
Maximum ambient temperature: 50°C.
Motor enclosure: IP55. Insulation class: F.
Cable: 1.5m with Australian plug.

✓ Electrical & Physical Details
CMB-SP 3-28
Power supply: 220-230V single phase, 50Hz.
Maximum current consumption: 3.30-3.15A.
Rated motor speed: 2750-2780rpm.
Net weight: 15kg.
Manufacturer product number: 98507627.

CMB-SP 3-37
Power supply: 220-230V single phase, 50Hz.
Maximum current consumption: 3.30-3.15A.
Rated motor speed: 2750-2780rpm.
Net weight: 15.4kg.
Manufacturer product number: 98507628.

CMB-SP 3-47
Power supply: 220-230V single phase, 50Hz.
Maximum current consumption: 3.30-3.15A.
Rated motor speed: 2750-2780rpm.
Net weight: 15.8kg.
Manufacturer product number: 98507629.

CMB-SP 3-56
Power supply: 220-240V single phase, 50Hz.
Maximum current consumption: 4.4-4.0A.
Rated motor speed: 2720-2800rpm.
Net weight: 17.6kg.
Manufacturer product number: 98507630.

CMB-SP 5-28
Power supply: 220-230V single phase, 50Hz.
Maximum current consumption: 3.30-3.15A.
Rated motor speed: 2750-2780rpm.
Net weight: 15kg.
Manufacturer product number: 98507635.

CMB-SP 5-47
Power supply: 220-240V single phase, 50Hz.
Maximum current consumption: 5.4-5.0A.
Rated motor speed: 2750-2790rpm.
Net weight: 18.3kg.
Manufacturer product number: 98507636.

The Grundfos CMB-SP 1-36 uses a 0.3kW fixed-speed multistage pump for automatic clean-water supply from tanks and other suitable water sources.

CMB-SP 1-36: rated duty 20LPM at 29.7m head.
Approximately 36m maximum pump head; 0.3kW motor.

Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.

The supplied PM1-15 pressure manager starts the pump automatically as water is used, with a fixed starting pressure of 150kPa. It stops the pump when demand ends. The starting pressure is not adjustable; water pressure while the pump runs depends on the pump and the water being used.

Rated duties are manufacturer flow-and-head reference points at 2900rpm, not maximum-flow ratings. Flow decreases as head increases. Select the pump for the flow and pressure required, allowing for suction lift, pipe friction and height differences.

Use clean fresh water without solid particles or fibres, at temperatures from 0°C to 40°C.

Self-priming does not mean the pump can start dry. Fill the pump casing with clean water through the filling opening before first use, then refit the plug and follow the startup instructions. The standard assembly supports a suction lift of up to 4m, including inlet-pipe losses at 20°C. Keep the suction pipe airtight and the pump close to the water source.

Install on a firm base in a ventilated, weather-protected position, with drainage and protection from frost.

The pump sleeve, impellers and shaft are stainless steel, with polymer components in the water path. The motor has built-in overload protection, and the pressure manager provides dry-running protection and a non-return valve.

Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

Grundfos CM Booster Self-Priming Product Brochure
Grundfos CM Pump Installation & Operating Instructions
Grundfos PM1 & PM2 Installation & Operating Instructions

✓ Application
The Grundfos CMB-SP 1-36 uses a 0.3kW fixed-speed multistage pump for automatic clean-water supply from tanks and other suitable water sources.

✓ Warranty
Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

✓ Model Specifications
CMB-SP 1-36
Rated duty: 20LPM at 29.7m head (manufacturer reference at 2900rpm).
Maximum pump head: approximately 36m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
PM1-15 fixed starting pressure: 150kPa.
Motor output P2: 0.3kW.

✓ Supplied Equipment & Control
The supplied PM1-15 pressure manager starts the pump automatically as water is used, with a fixed starting pressure of 150kPa. It stops the pump when demand ends. The starting pressure is not adjustable; water pressure while the pump runs depends on the pump and the water being used.
No external pressure tank supplied.

✓ Performance
Rated duties are manufacturer flow-and-head reference points at 2900rpm, not maximum-flow ratings. Flow decreases as head increases. Select the pump for the flow and pressure required, allowing for suction lift, pipe friction and height differences.
Maximum heads shown are approximate readings from the manufacturer’s booster curves, not the pressure available at every flow.

✓ Pressure Limits
Maximum system pressure: 1000kPa. Inlet pressure plus pump pressure must stay within this limit.

✓ Water Supply
Use clean fresh water without solid particles or fibres, at temperatures from 0°C to 40°C.

✓ Installation & Priming
Self-priming does not mean the pump can start dry. Fill the pump casing with clean water through the filling opening before first use, then refit the plug and follow the startup instructions. The standard assembly supports a suction lift of up to 4m, including inlet-pipe losses at 20°C. Keep the suction pipe airtight and the pump close to the water source.
Protect the pump and pressure manager from rain, direct sunlight and frost. Follow the supplied instructions for commissioning and pipework arrangement.

✓ Construction & Protection
The pump sleeve, impellers and shaft are stainless steel, with polymer components in the water path. The motor has built-in overload protection, and the pressure manager provides dry-running protection and a non-return valve.

✓ Electrical Supply
Maximum ambient temperature: 50°C.
Motor enclosure: IP55. Insulation class: F.
Cable: 1.5m with Australian plug.

✓ Electrical & Physical Details
CMB-SP 1-36
Power supply: 220-230V single phase, 50Hz.
Maximum current consumption: 2.10-2.05A.
Rated motor speed: 2800-2820rpm.
Net weight: 14.6kg.
Manufacturer product number: 98507562.

The Grundfos SCALA2 3-45 supplies clean water for household taps, showers and garden watering. Its variable-speed motor responds to changes in water use, helping keep outlet pressure steady as taps open and close. The pump, controller, pressure sensor, pressure tank and non-return valves are integrated into one compact unit.

Rated duty: 50LPM at 27m head.
Maximum flow: 76.7LPM.
Maximum head: 45m.

The rated duty gives a flow and head together. Maximum flow and maximum head occur at different operating points. Available flow falls as the pump works against more head; pipe losses and height differences also affect pressure at the tap.

Inlet: 1" BSP male thread.
Outlet: 1" BSP male thread.

Set the outlet pressure with the up and down buttons on the control panel. The setting changes in 50kPa steps from 150 to 550kPa; the factory setting is 300kPa. The indicator lights show the selected pressure.

Settings of 400–550kPa require water that is already under pressure as it enters the pump. The pump then adds to that incoming pressure. These settings are not suitable for drawing from a tank below the pump. Grundfos limits the pressure increase between inlet and outlet to 350kPa when choosing a setting; an installer should select a setting the pump can maintain at the required flow.

Use clean, fresh water at 0°C to 45°C. Sand and debris can wear or block the pump; use suitable inlet filtration where the water source requires it.

Self-priming means the pump can clear air from the inlet pipe and draw water up to the pump after its housing has been filled with water. Before starting, remove the priming plug, pour at least 1.7L of clean water into the pump housing and refit the plug. Do not switch it on with an empty housing or let it run without a water supply.

Maximum suction lift is 8m; pipe resistance and inlet conditions affect the usable lift. Install on a firm base with drainage and protection from frost, following the installation instructions.

Dry-running and thermal protection help protect the pump. The built-in tank needs no separate pressure tank for normal operation. Check its gas precharge annually and when changing the pressure setting; Grundfos recommends 70% of the selected outlet pressure, checked with the water side depressurised. The installation instructions explain the procedure.

Supplied with a 1.5m power lead and Australian three-pin plug for a 200–240V single-phase, 50/60Hz supply.

Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

Grundfos SCALA2 Installation & Operating Instructions
Grundfos SCALA2 Data Sheet
Grundfos SCALA2 Australian Safety Instructions

✓ Application
The Grundfos SCALA2 3-45 supplies clean water for household taps, showers and garden watering.

✓ Warranty
Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

✓ Connections
Inlet: 1" BSP male thread (R1).
Outlet: 1" BSP male thread (R1).

✓ Performance
Rated flow: 3m3/h (50LPM) at 27m head.
Maximum flow: 4.6m3/h (76.7LPM, rounded to one decimal).
Maximum head: 45m.
Maximum flow and maximum head occur separately; select the pump using the flow required at the working head.

✓ Pressure Control
Variable-speed control with integrated outlet pressure sensor.
Factory outlet pressure setting: 300kPa.
Selectable outlet pressure: 150–550kPa in 50kPa steps, using the up and down buttons.
Usable settings depend on inlet pressure and pump capacity. Settings of 400kPa and above require positive inlet pressure; follow the manual's application limits.
Maximum pressure increase between inlet and outlet when selecting a setting: 350kPa.
Maximum inlet pressure: 600kPa.
Maximum operating pressure: 1000kPa. This is the system pressure limit, not the pressure the pump can add.

✓ Pressure Tank
Factory gas precharge: 180kPa.
Recommended adjusted precharge: 70% of the selected outlet pressure, measured with no water pressure in the tank.
Check annually and when changing the outlet pressure setting. Follow the manual's procedure.

✓ Water Supply
Clean, thin, fresh water; liquid temperature 0°C to 45°C.
Water pH: 4–9; maximum chloride content 300ppm; free chlorine below 1ppm.

✓ Installation & Priming
Maximum suction lift: 8m; allow for inlet pipe losses and follow the manual's suction-installation requirements.
Ambient temperature: 0°C to 55°C.
Initial filling: at least 1.7L of clean water through the priming opening before starting.
For suction installations, remove the locking pin if fitted; it disables self-priming. Refer to the installation instructions.
Install horizontally on a firm base with drainage; protect against freezing.

✓ Construction & Protection
Composite pump housing and impellers.
Ceramic/carbon shaft seal with EPDM elastomer.
Integrated pressure tank, pressure sensor, controller and non-return valves.
Dry-running and thermal protection.
Micro-leakage shutdown and the 30-minute maximum-run timer are optional installer settings, switched off at the factory. Do not assume they are enabled on delivery.
Dry-running alarms require manual reset after the cause has been corrected and the pump primed; automatic reset is not universal.

✓ Electrical Supply
Rated motor output P2: 0.45kW.
Power input P1: 550W.
Power supply: 200–240V single phase, 50/60Hz.
Maximum current: 2.8A.
Power lead: 1.5m with Australian three-pin plug.
Enclosure: IPX4D. Insulation: Class F.

✓ Dimensions, Weight & Noise
Overall dimensions: 403mm long x 193mm wide x 302mm high.
Net weight: 9.63kg for product 93059923.
Typical noise level: 44dB(A), measured at 16.7LPM and 19m head under ISO 3745; actual installation noise varies.

✓ Product Identification
Model: SCALA2 3-45, Model 2.
Manufacturer product number: 93059923.
EAN: 5715467195309.
Australian drinking-water approval listed by Grundfos: AS4020.

Video 1

Video 2

Video 3

Grundfos CME Booster Pump CMBE3-62 (0.55kW)

Grundfos CMBE variable-speed boosters provide automatic clean-water supply for domestic and light commercial use. They adjust motor speed as water demand changes to help maintain steady outlet pressure.

CMBE 1-44: rated duty 40LPM at 28.7m head.
CMBE 3-62: rated duty 70LPM at 45.2m head.
CMBE 5-62: rated duty 100LPM at 47.8m head.

Rated duty pairs show flow at the stated head; they are not maximum-flow ratings.

Maximum operating pressure is 1000kPa. Inlet pressure and the pressure added by the pump must remain within this limit. Flow decreases as head increases; the pressure available at a tap also depends on elevation and pipe resistance.

The CMBE 1-44 and CMBE 3-62 both have a 1" BSP female inlet.
The CMBE 5-62 has a larger 1 1/4" BSP female inlet.
All three have a 1" BSP female outlet.

These pumps are for clean, thin, non-aggressive, non-toxic and non-explosive liquids without solid particles or fibres, at liquid temperatures from 0°C to 60°C.

Set the desired outlet pressure using the up/down buttons on the motor control panel. Illuminated bars indicate the setting, while the fitted gauge shows actual outlet pressure. The pump uses an outlet pressure sensor to adjust its speed as demand changes, maintaining the selected pressure within its capacity. Readjust the tank precharge whenever the selected outlet pressure changes.

The pump housing, impellers and shaft are 304 stainless steel. A 2L diaphragm tank, pressure sensor and gauge are supplied as part of the booster assembly. Dry-running protection stops the pump when a lack of water is detected and provides automatic restart attempts. Built-in motor protection covers thermal overload and blocking; no separate external motor protection is required.

CMBE pumps are not self-priming. Before starting, fill the pump casing with clean water through the priming opening and let trapped air escape, following the installation instructions. Maximum suction lift is 1m at a water temperature of 20°C, including inlet pipe pressure loss. Install horizontally on a firm base with space for motor cooling and suitable weather protection and drainage.

All three Australian plug versions use a 200-240V single-phase, 50/60Hz supply.

Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

Grundfos CMBE Installation & Operating Instructions

✓ Application
Variable-speed multistage centrifugal booster for domestic and light commercial clean-water supply.

✓ Warranty
Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

✓ Model Specifications

CMBE 1-44
Maximum total head: 44m.
Rated duty: 40 LPM at 28.7m head.
Inlet: 1" BSP female thread.
Outlet: 1" BSP female thread.
Motor output P2: 0.55kW.

CMBE 3-62
Maximum total head: 62m.
Rated duty: 70 LPM at 45.2m head.
Inlet: 1" BSP female thread.
Outlet: 1" BSP female thread.
Motor output P2: 1.1kW.

CMBE 5-62
Maximum total head: 62m.
Rated duty: 100 LPM at 47.8m head.
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Motor output P2: 1.5kW.

✓ Performance
Rated duty is the manufacturer’s stated flow and head at its reference speed; it is not maximum flow or guaranteed flow at every pressure setting.
Flow decreases as head increases. Select the duty to suit the required flow and pressure.

✓ Control
Set the desired outlet pressure using the up/down buttons on the motor control panel. Illuminated bars indicate the setting, while the fitted gauge shows actual outlet pressure. The pump uses an outlet pressure sensor to adjust its speed as demand changes, maintaining the selected pressure within its capacity. Readjust the tank precharge whenever the selected outlet pressure changes.

✓ Protection
Dry-running protection stops the pump when a lack of water is detected and provides automatic restart attempts. Built-in motor protection covers thermal overload and blocking; no separate external motor protection is required.

✓ Pressure Tank
Precharge is the pressure of the gas cushion inside the diaphragm tank, measured with the water pressure fully released. Set it to 70% of the selected outlet pressure and readjust it whenever that setting changes. See the installation instructions for the adjustment procedure.

✓ Pressure Limits
Maximum operating pressure: 1000kPa.
Maximum outlet pressure: 1000kPa.
Inlet pressure plus pump pressure must remain within the operating limit.

✓ Water Supply
These pumps are for clean, thin, non-aggressive, non-toxic and non-explosive liquids without solid particles or fibres, at liquid temperatures from 0°C to 60°C.

✓ Installation & Priming
CMBE pumps are not self-priming. Before starting, fill the pump casing with clean water through the priming opening and let trapped air escape, following the installation instructions. Maximum suction lift is 1m at a water temperature of 20°C, including inlet pipe pressure loss. Install horizontally on a firm base with space for motor cooling and suitable weather protection and drainage.
Maximum start/stop frequency: 100 per hour.

✓ Construction
The pump housing, impellers and shaft are 304 stainless steel. A 2L diaphragm tank, pressure sensor and gauge are supplied as part of the booster assembly.

✓ Electrical Supply
200-240V single phase, 50/60Hz.
Australian plug version.
Motor enclosure: IP55. Pressure sensor enclosure: IP44.
Motor insulation: Class F.
Motor speed range: 360-4000rpm.
Cable: 1.5m with Australian plug.

✓ Electrical & Physical Details

CMBE 1-44
Input power P1: 615W.
Maximum current consumption: 3.45-2.90A.
Overall dimensions: 326mm long x 217mm wide x 440mm high.
Mounting-hole spacing, measured centre to centre: 95mm front to back x 158mm side to side; four 10mm holes.
Net weight: 16kg.
Manufacturer product number: 98374705.

CMBE 3-62
Input power P1: 1210W.
Maximum current consumption: 6.70-5.60A.
Overall dimensions: 344mm long x 217mm wide x 440mm high.
Mounting-hole spacing, measured centre to centre: 95mm front to back x 158mm side to side; four 10mm holes.
Net weight: 17kg.
Manufacturer product number: 98374709.

CMBE 5-62
Input power P1: 1720W.
Maximum current consumption: 9.10-7.60A.
Overall dimensions: 350mm long x 217mm wide x 455mm high.
Mounting-hole spacing, measured centre to centre: 125mm front to back x 178mm side to side; four 10mm holes.
Net weight: 19.3kg.
Manufacturer product number: 98374712.

Franklin 3AMH pressure pump packages supply clean water for household use, garden irrigation and water distribution. Choose a pump model for the required flow and pressure, then select an 8L, 18L, 35L or 60L tank. Each package includes a fixed-speed multistage pump, pressure switch and the selected tank.

3AMH2B-51: 50LPM at 15.5m head; maximum head 22.4m.
3AMH3B-51: 50LPM at 22.5m head; maximum head 33.2m.
3AMH4B-51: 50LPM at 29.1m head; maximum head 43.7m.
3AMH5B-51: 50LPM at 35.2m head; maximum head 54m.
3AMH6B-51: 50LPM at 42.8m head; maximum head 65.1m.

These paired reference points show flow at a stated head. Maximum head is the zero-flow figure and occurs separately. Select the pump for the flow needed at the working head, allowing for pipe losses and height differences.

Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

The pump determines the available flow and pressure. Changing tank size does not increase the pump’s performance. A larger tank generally stores more usable water between pump starts, helping reduce how often the pump starts during intermittent use.

Tank choices: 8L, 18L, 35L or 60L nominal capacity. These are vessel sizes, not the amounts of water available between starts; usable storage depends on the switch settings and tank precharge.

The pressure switch starts the pump when pressure falls to its start setting and stops it at its stop setting. Pressure varies between these settings during use. An installer sets the switch and tank precharge to suit the pump, required water supply and component pressure limits.

Use clean water without sand, solids or fibres. The pump body, impellers and diffusers use 300-series stainless steel.

The pump is not self-priming. Fill the pump and suction pipe with clean water before starting, and use a suitable valve arrangement to retain that water where suction lift is required. Install on a firm base with drainage and motor ventilation, following the pump manual.

Supplied for a 220–240V single-phase, 50Hz supply with an AU/NZ plug. Do not let the pump run without water; arrange suitable protection against loss of supply.

Franklin MH Pump Installation & Operating Manual
Franklin MH Australian Product Brochure

✓ Application
Franklin 3AMH pressure pump packages supply clean water for household use, garden irrigation and water distribution.

✓ Model Specifications

3AMH2B-51
Flow/head reference: 50LPM at 15.5m head.
Maximum pump head: 22.4m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

3AMH3B-51
Flow/head reference: 50LPM at 22.5m head.
Maximum pump head: 33.2m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

3AMH4B-51
Flow/head reference: 50LPM at 29.1m head.
Maximum pump head: 43.7m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

3AMH5B-51
Flow/head reference: 50LPM at 35.2m head.
Maximum pump head: 54m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

3AMH6B-51
Flow/head reference: 50LPM at 42.8m head.
Maximum pump head: 65.1m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

✓ Supplied Package & Control
Multistage pump, pressure switch and selected pressure tank included.
Tank choices: 8L, 18L, 35L or 60L nominal capacity; usable storage depends on pressure settings and precharge.
Fixed-speed operation; water pressure varies between the switch start and stop settings.
An installer sets the start/stop pressures within the pump's capability and every component's pressure rating.
A larger tank does not increase the pump's available flow or head.

✓ Pressure Limits
Maximum pump operating pressure: 1000kPa; inlet pressure plus pump pressure must remain within this limit. Other package components may have lower limits.

✓ Water Supply
Clean water without abrasive particles, solids or fibres.

✓ Installation & Priming
Not self-priming; fill pump and suction pipe before starting.
Use suitable inlet valves to retain prime where suction lift is required; follow the pump manual.
Install horizontally on a firm base with supported pipework, drainage and motor ventilation.
Arrange suitable protection against loss of water supply.

✓ Construction
300-series stainless-steel hydraulic components.

✓ Electrical Supply
Supply: 220–240V single phase, 50Hz, with AU/NZ plug.
Motor insulation: Class F. Built-in thermal protection. Refer to the supplied motor nameplate for its enclosure rating.
Maximum pump ambient temperature: 40°C.
Use the supplied motor nameplate for output and current ratings.

Franklin 5AMH pressure pump packages supply clean water for household use, garden irrigation and water distribution. Choose a pump model for the required flow and pressure, then select an 8L, 18L, 35L or 60L tank. Each package includes a fixed-speed multistage pump, pressure switch and the selected tank.

5AMH2B-51: 75LPM at 15m head; maximum head 23.5m.
5AMH3B-51: 75LPM at 21.3m head; maximum head 34.8m.
5AMH4B-51: 75LPM at 28.4m head; maximum head 46.2m.
5AMH5B-51: 75LPM at 34m head; maximum head 57.3m.
5AMH6B-51: 75LPM at 43.2m head; maximum head 69.5m.

These paired reference points show flow at a stated head. Maximum head is the zero-flow figure and occurs separately. Select the pump for the flow needed at the working head, allowing for pipe losses and height differences.

Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

The pump determines the available flow and pressure. Changing tank size does not increase the pump’s performance. A larger tank generally stores more usable water between pump starts, helping reduce how often the pump starts during intermittent use.

Tank choices: 8L, 18L, 35L or 60L nominal capacity. These are vessel sizes, not the amounts of water available between starts; usable storage depends on the switch settings and tank precharge.

The pressure switch starts the pump when pressure falls to its start setting and stops it at its stop setting. Pressure varies between these settings during use. An installer sets the switch and tank precharge to suit the pump, required water supply and component pressure limits.

Use clean water without sand, solids or fibres. The pump body, impellers and diffusers use 300-series stainless steel.

The pump is not self-priming. Fill the pump and suction pipe with clean water before starting, and use a suitable valve arrangement to retain that water where suction lift is required. Install on a firm base with drainage and motor ventilation, following the pump manual.

Supplied for a 220–240V single-phase, 50Hz supply with an AU/NZ plug. Do not let the pump run without water; arrange suitable protection against loss of supply.

Franklin MH Pump Installation & Operating Manual
Franklin MH Australian Product Brochure

✓ Application
Franklin 5AMH pressure pump packages supply clean water for household use, garden irrigation and water distribution.

✓ Model Specifications

5AMH2B-51
Flow/head reference: 75LPM at 15m head.
Maximum pump head: 23.5m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

5AMH3B-51
Flow/head reference: 75LPM at 21.3m head.
Maximum pump head: 34.8m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

5AMH4B-51
Flow/head reference: 75LPM at 28.4m head.
Maximum pump head: 46.2m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

5AMH5B-51
Flow/head reference: 75LPM at 34m head.
Maximum pump head: 57.3m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

5AMH6B-51
Flow/head reference: 75LPM at 43.2m head.
Maximum pump head: 69.5m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/4" BSP female thread.
Pump outlet: 1" BSP female thread.

✓ Supplied Package & Control
Multistage pump, pressure switch and selected pressure tank included.
Tank choices: 8L, 18L, 35L or 60L nominal capacity; usable storage depends on pressure settings and precharge.
Fixed-speed operation; water pressure varies between the switch start and stop settings.
An installer sets the start/stop pressures within the pump's capability and every component's pressure rating.
A larger tank does not increase the pump's available flow or head.

✓ Pressure Limits
Maximum pump operating pressure: 1000kPa; inlet pressure plus pump pressure must remain within this limit. Other package components may have lower limits.

✓ Water Supply
Clean water without abrasive particles, solids or fibres.

✓ Installation & Priming
Not self-priming; fill pump and suction pipe before starting.
Use suitable inlet valves to retain prime where suction lift is required; follow the pump manual.
Install horizontally on a firm base with supported pipework, drainage and motor ventilation.
Arrange suitable protection against loss of water supply.

✓ Construction
300-series stainless-steel hydraulic components.

✓ Electrical Supply
Supply: 220–240V single phase, 50Hz, with AU/NZ plug.
Motor insulation: Class F. Built-in thermal protection. Refer to the supplied motor nameplate for its enclosure rating.
Maximum pump ambient temperature: 40°C.
Use the supplied motor nameplate for output and current ratings.
Franklin Pressure Pump 9AMH3B-51, 150 LPM - Single Phase, Includes 8L Pressure Tank and Pressure Switch

Franklin 9AMH pressure pump packages supply clean water for household use, garden irrigation and water distribution. Choose a pump model for the required flow and pressure, then select an 8L, 18L, 35L or 60L tank. Each package includes a fixed-speed multistage pump, pressure switch and the selected tank.

9AMH2B-51: 166.7LPM at 15.6m head; maximum head 23.7m.
9AMH3B-51: 166.7LPM at 22.8m head; maximum head 35.3m.
9AMH4B-51: 166.7LPM at 31.7m head; maximum head 47.4m.

These paired reference points show flow at a stated head. Maximum head is the zero-flow figure and occurs separately. Select the pump for the flow needed at the working head, allowing for pipe losses and height differences.

Pump inlet: 1 1/2" BSP female thread.
Pump outlet: 1 1/4" BSP female thread.

The pump determines the available flow and pressure. Changing tank size does not increase the pump’s performance. A larger tank generally stores more usable water between pump starts, helping reduce how often the pump starts during intermittent use.

Tank choices: 8L, 18L, 35L or 60L nominal capacity. These are vessel sizes, not the amounts of water available between starts; usable storage depends on the switch settings and tank precharge.

The pressure switch starts the pump when pressure falls to its start setting and stops it at its stop setting. Pressure varies between these settings during use. An installer sets the switch and tank precharge to suit the pump, required water supply and component pressure limits.

Use clean water without sand, solids or fibres. The pump body, impellers and diffusers use 300-series stainless steel.

The pump is not self-priming. Fill the pump and suction pipe with clean water before starting, and use a suitable valve arrangement to retain that water where suction lift is required. Install on a firm base with drainage and motor ventilation, following the pump manual.

Supplied for a 220–240V single-phase, 50Hz supply with an AU/NZ plug. Do not let the pump run without water; arrange suitable protection against loss of supply.

Franklin MH Pump Installation & Operating Manual
Franklin MH Australian Product Brochure

✓ Application
Franklin 9AMH pressure pump packages supply clean water for household use, garden irrigation and water distribution.

✓ Model Specifications

9AMH2B-51
Flow/head reference: 166.7LPM at 15.6m head.
Maximum pump head: 23.7m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/2" BSP female thread.
Pump outlet: 1 1/4" BSP female thread.

9AMH3B-51
Flow/head reference: 166.7LPM at 22.8m head.
Maximum pump head: 35.3m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/2" BSP female thread.
Pump outlet: 1 1/4" BSP female thread.

9AMH4B-51
Flow/head reference: 166.7LPM at 31.7m head.
Maximum pump head: 47.4m (zero flow).
Tank sizes available: 8L, 18L, 35L and 60L.
Pump inlet: 1 1/2" BSP female thread.
Pump outlet: 1 1/4" BSP female thread.

✓ Supplied Package & Control
Multistage pump, pressure switch and selected pressure tank included.
Tank choices: 8L, 18L, 35L or 60L nominal capacity; usable storage depends on pressure settings and precharge.
Fixed-speed operation; water pressure varies between the switch start and stop settings.
An installer sets the start/stop pressures within the pump's capability and every component's pressure rating.
A larger tank does not increase the pump's available flow or head.

✓ Pressure Limits
Maximum pump operating pressure: 1000kPa; inlet pressure plus pump pressure must remain within this limit. Other package components may have lower limits.

✓ Water Supply
Clean water without abrasive particles, solids or fibres.

✓ Installation & Priming
Not self-priming; fill pump and suction pipe before starting.
Use suitable inlet valves to retain prime where suction lift is required; follow the pump manual.
Install horizontally on a firm base with supported pipework, drainage and motor ventilation.
Arrange suitable protection against loss of water supply.

✓ Construction
300-series stainless-steel hydraulic components.

✓ Electrical Supply
Supply: 220–240V single phase, 50Hz, with AU/NZ plug.
Motor insulation: Class F. Built-in thermal protection. Refer to the supplied motor nameplate for its enclosure rating.
Maximum pump ambient temperature: 40°C.
Use the supplied motor nameplate for output and current ratings.
Davey XF171 (175 LPM Max Flow, 0.53kW)

Davey XF transfer pumps supply clean water for irrigation, water transfer, washdown, aquaculture and hydroponics. XF171 and XF221 are single-stage pumps; XF192 is a twin-stage pump for duties needing more head.

XF171: maximum flow 175LPM; maximum head 17m; 0.53kW motor.
XF221: maximum flow 225LPM; maximum head 20m; 0.7kW motor.
XF192: maximum flow 190LPM; maximum head 33m; 0.8kW motor.

Maximum flow and maximum head are separate limits. Available flow decreases as the pump works against more head. Use the performance curve to check the required flow and pressure, including pipe losses and height differences.

XF171 and XF221: 1" BSP female inlet; 1" BSP male outlet.
XF192: 1" BSP female inlet; 1" BSP female outlet.

These are standard transfer pumps. They do not automatically start and stop as taps open and close; automatic operation requires suitable separate controls. The supplied motor has automatic-reset thermal-overload protection.

Maximum suction lift is 7.5m, with usable lift depending on inlet conditions and suction-pipe losses. Before starting, fill the pump casing and suction line through the priming opening above the inlet, then refit the plug. Suction-lift installations need a good-quality foot valve to retain prime.

Use clean, non-volatile liquids without fibres, solids or abrasive material, at temperatures from 1°C to 50°C. Do not run the pump dry, with loss of prime or for prolonged periods against a closed outlet.

Install horizontally on a firm base near the water source, with drainage and a weatherproof, frost-free, ventilated enclosure. Support the pipework and keep suction connections airtight.

Each pump uses a 220–240V single-phase, 50Hz supply and comes with a 2m power lead and Australian 10amp three-pin plug.

Davey provides a two-year warranty, subject to its terms.

Davey XF Series Specifications
Davey XF Series Installation & Operating Instructions

✓ Application
Davey XF transfer pumps supply clean water for irrigation, water transfer, washdown, aquaculture and hydroponics.

✓ Warranty
Two-year Davey warranty, subject to its terms.

✓ Model Specifications

XF171
Maximum flow: 175LPM.
Maximum total head: 17m.
Pump inlet: 1" BSP female thread.
Pump outlet: 1" BSP male thread.
Motor output P2: 0.53kW.
Pump stages: 1.
Pump casing: Glass-filled Noryl.

XF221
Maximum flow: 225LPM.
Maximum total head: 20m.
Pump inlet: 1" BSP female thread.
Pump outlet: 1" BSP male thread.
Motor output P2: 0.7kW.
Pump stages: 1.
Pump casing: Glass-filled Noryl.

XF192
Maximum flow: 190LPM.
Maximum total head: 33m.
Pump inlet: 1" BSP female thread.
Pump outlet: 1" BSP female thread.
Motor output P2: 0.8kW.
Pump stages: 2.
Pump casing: 304 stainless steel.

✓ Performance
Maximum flow and maximum head occur separately; use the performance curve for the required flow at the working head.

✓ Supplied Operation & Protection
Standard electric transfer pump with 2m power lead and Australian 10amp three-pin plug.
The standard pump does not automatically start and stop as taps open and close; automatic operation requires suitable separate controls.
Built-in automatic-reset motor thermal-overload protection.
Motor overload protection does not permit dry running or prolonged operation against a closed outlet.

✓ Installation & Priming
Maximum suction lift: 7.5m; account for suction-pipe losses and inlet conditions.
Fill the pump casing and suction line through the priming opening above the inlet before starting.
Fit a good-quality foot valve for suction-lift installations to retain prime.
Install horizontally on a firm base near the water source. Provide drainage and a weatherproof, frost-free, ventilated enclosure.
Mounting holes: 10mm diameter at 140mm centres; refer to the dimension drawing for placement.
Keep suction joints airtight and support the pipework; do not run dry or with loss of prime.

✓ Water Supply
Clean, non-volatile liquids without fibres, solids or abrasive material.
Water temperature: 1°C to 50°C.

✓ Construction
Glass-filled polycarbonate impellers; glass-filled Noryl diffusers and suction cover.
304 stainless-steel pump shaft and clamp band.
Ceramic/carbon mechanical seal with nitrile O-rings.
Marine-grade aluminium motor shell with baked polyester finish.

✓ Electrical Supply
Maximum ambient temperature: 50°C.
Power supply: 220–240V single phase, 50Hz.
Nominal motor speed: 2850rpm.
Motor enclosure: IP55. Insulation: Class F.
Permanently split capacitor motor with sealed bearings.

✓ Electrical & Physical Details

XF171
Electrical input P1: 0.78kW.
Full-load current: 2.8A.
Locked-rotor current: 12A.
Overall dimensions: 325mm long x 193mm wide x 215mm high.
Net weight: 6.7kg.
Manufacturer part number: 71101.

XF221
Electrical input P1: 1.05kW.
Full-load current: 4.5A.
Locked-rotor current: 18A.
Overall dimensions: 350mm long x 193mm wide x 215mm high.
Net weight: 8.3kg.
Manufacturer part number: 71201.

XF192
Electrical input P1: 1.15kW.
Full-load current: 5.2A.
Locked-rotor current: 18A.
Overall dimensions: 350mm long x 195mm wide x 220mm high.
Net weight: 8.8kg.
Manufacturer part number: 71301.

The Davey Boremaster 60061R is a single phase single stage centrifugal transfer pump designed for shallow well applications, garden reticulation and general water transfer. It delivers flow rates up to 315 LPM with a maximum total head of 31.6m. Flow decreases as head increases.

Specially designed to suit Western Australian conditions, the Boremaster 60061R is suitable for drawing water from depths up to 7m. It includes a 1 1/2" BSP female inlet, 1 1/4" BSP female outlet and glass filled Noryl pump casing with strengthened inlet and outlet ports.

The single phase motor includes IP56 protection, built-in thermal overload protection with automatic reset and a 2m power lead with Australian 10amp plug. Correct installation, priming and use of a suitable foot valve are required for reliable suction lift operation.

Davey 2 Year Warranty.

Davey 60061R Specifications
Davey 60061R Installation & User Manual

✓ Application
Single stage centrifugal transfer pump suitable for shallow well applications, garden reticulation and general water transfer.

✓ Warranty
Davey 2 Year Warranty.

✓ Performance
Capacities up to 315 LPM with a maximum total head of 31.6m.

✓ Connections
1 1/2" BSP female inlet.
1 1/4" BSP female outlet.

✓ Pressure Limits
50m maximum casing pressure.

✓ Water Supply
Suitable for water temperatures from 1°C to 50°C continuous, with 70°C peak for up to 10 minutes.

✓ Installation & Priming
Install with a suitable foot valve for suction lift applications to help avoid loss of prime.
7.0m maximum suction head.
Pump body and suction line must be filled through the priming plug before operation.

✓ Construction
Glass filled Noryl pump casing with metal hoop strengthened inlet and outlet ports.
Glass filled polycarbonate impeller.
304 stainless steel shaft.
Ceramic stationary seal ring and carbon rotating seal ring with nitrile rubber elastomer.

✓ Electrical Supply
IP56 motor protection rating with built-in thermal overload protection and automatic reset.
Single phase operation.
220-250V, 50Hz supply.
2.1kW input power.
1.6kW output power.
9.2A full load current.
40A locked rotor current.
2m power lead with Australian 10amp three pin plug.

✓ Dimensions & Weight
19.0kg net weight.

✓ Product Identification
Davey Boremaster 60061R transfer pump.

The Davey Dynaflo 6220-3 is a three phase single stage centrifugal transfer pump designed for water supply, water transfer, tank filling, sprinkler supply and garden reticulation. It delivers flow rates up to 360 LPM with a maximum total head of 38.7m. Flow decreases as head increases.

The Dynaflo 6220-3 includes a 2" BSP female inlet and 1 1/2" BSP female outlet, making it suitable for higher flow transfer and irrigation applications. The cast iron pump casing features a baked polyester finish inside and outside for long service life.

The Davey manufactured three phase motor includes IP56 protection for reliable operation in farm, irrigation and light commercial applications. Correct installation, priming, pipework support and three phase electrical connection are required for safe and reliable pump operation.

Davey 2 Year Warranty.

Davey 6220-3 Specifications
Davey 6220-3 Installation & User Manual

✓ Application
Single stage centrifugal transfer pump suitable for water supply, water transfer, tank filling, sprinkler supply, garden reticulation, dairies and factory floor washdown.

✓ Warranty
Davey 2 Year Warranty.

✓ Performance
Capacities up to 360 LPM with a maximum total head of 38.7m.

✓ Connections
2" BSP female inlet.
1 1/2" BSP female outlet.

✓ Pressure Limits
105m maximum casing pressure.

✓ Water Supply
Suitable for water temperatures from 1°C to 50°C.

✓ Installation & Priming
Three phase power connection must be carried out by an authorised electrician.
7.0m maximum suction head.
Pump body and suction line must be filled through the priming plug before operation.

✓ Construction
Cast iron pump casing with baked polyester finish.
Glass filled polycarbonate impeller.
304 stainless steel shaft.
Ceramic stationary seal ring and carbon rotating seal ring with nitrile rubber elastomer.

✓ Electrical Supply
IP56 motor protection rating. Three phase models must be wired with suitable contactor and overload protection.
Three phase operation.
Three phase 380-415V, 50Hz supply.
2.63kW input power.
2.2kW output power.
4.5A full load current.
24A locked rotor current.

✓ Dimensions & Weight
29.7kg net weight.

✓ Product Identification
Davey Dynaflo 6220-3 / 62203 transfer pump.
Franklin MultiStage Transfer Pump 3AMH2B-51, 50LPM, 0.33KW - Single Phase

Franklin MH3 horizontal multistage pumps supply clean water for water transfer, pressure boosting, irrigation and washdown. Choose the stage count for the required flow and pressure, then select single-phase or three-phase supply.

These listings are for bare pump-and-motor units. Suitable separate controls are required for automatic operation as taps open and close; a pressure tank is not included.

3AMH2B: 50LPM at 15.5m head; maximum head 22.4m.
3AMH3B: 50LPM at 22.5m head; maximum head 33.2m.
3AMH4B: 50LPM at 29.1m head; maximum head 43.7m.
3AMH5B: 50LPM at 35.2m head; maximum head 54m.
3AMH6B: 50LPM at 42.8m head; maximum head 65.1m.
3AMH7B: 50LPM at 48.7m head; maximum head 75.3m.
3AMH8B: 50LPM at 58.8m head; maximum head 87.6m.
3AMH9B: 50LPM at 65.2m head; maximum head 98m.

The paired figures show flow at a stated head. Maximum head occurs at zero flow, separately from the listed flow. Allow for inlet conditions, height differences and pipe losses when selecting the pump.

Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.

The pump body, impellers and diffusers are 304 stainless steel. Use clean water without solid particles or fibres, compatible with the pump materials. Maximum water temperature is 55°C for single-phase models and 85°C for three-phase models in domestic and commercial use. The higher 110°C three-phase limit is for industrial applications only.

The pump is not self-priming. Fill the pump casing and suction pipe before starting, and use suitable inlet valves to retain prime where suction lift is required. Install on a firm base with drainage, supported pipework, ventilation and protection from weather and freezing. Do not run without water or against a closed outlet.

Maximum operating pressure is 1000kPa; inlet pressure and the pressure added by the pump must remain within this limit.

Single-phase versions use a 220–240V, 50Hz supply, have an AU/NZ plug and include motor thermal overload protection. Three-phase versions use a 380–415V, 50Hz supply and require an electrician connection and external motor protection.

Two-year Franklin Electric pump warranty, subject to its terms.

Franklin MH Pump Installation & Operating Manual

✓ Application
Clean-water transfer, pressure boosting, domestic water supply, garden irrigation and washdown.

✓ Warranty
Two-year Franklin Electric pump warranty, subject to its terms.

✓ Model Specifications
3AMH2B
Flow/head reference: 50LPM at 15.5m head.
Maximum pump head: 22.4m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH2B-51 single phase, 3AMH2B-53 three phase.

3AMH3B
Flow/head reference: 50LPM at 22.5m head.
Maximum pump head: 33.2m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH3B-51 single phase, 3AMH3B-53 three phase.

3AMH4B
Flow/head reference: 50LPM at 29.1m head.
Maximum pump head: 43.7m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH4B-51 single phase, 3AMH4B-53 three phase.
Single-phase motor output P2: 0.55kW.

3AMH5B
Flow/head reference: 50LPM at 35.2m head.
Maximum pump head: 54m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH5B-51 single phase, 3AMH5B-53 three phase.
Motor output P2: 0.75kW for the listed versions.

3AMH6B
Flow/head reference: 50LPM at 42.8m head.
Maximum pump head: 65.1m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH6B-51 single phase, 3AMH6B-53 three phase.

3AMH7B
Flow/head reference: 50LPM at 48.7m head.
Maximum pump head: 75.3m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH7B-51 single phase, 3AMH7B-53 three phase.
Motor output P2: 1.1kW for the listed versions.

3AMH8B
Flow/head reference: 50LPM at 58.8m head.
Maximum pump head: 87.6m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH8B-51 single phase, 3AMH8B-53 three phase.

3AMH9B
Flow/head reference: 50LPM at 65.2m head.
Maximum pump head: 98m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH9B-51 single phase, 3AMH9B-53 three phase.
Motor output P2: 1.5kW for the listed versions.

✓ Supplied Operation
Bare pump-and-motor unit; pressure tank and automatic demand controls are supplied separately.
The pump does not automatically start and stop as taps open and close without suitable separate controls.

✓ Performance & Pressure Limits
The paired figures show the flow available at a stated head.
Application flow range: 25–75LPM; select the stage count for the required head.
Maximum head is the zero-flow figure and occurs separately from the listed flow.
Maximum operating pressure: 1000kPa. Inlet pressure plus pump pressure must remain within this limit.
Select the pump for the required flow and head, allowing for height differences and pipe losses.
Do not run against a closed outlet or below the manufacturer's minimum operating flow.

✓ Water Supply
Clean, non-aggressive liquids compatible with the pump materials, without solids or fibres.
Maximum water temperature: single phase 55°C; three phase 85°C for domestic/commercial use, or 110°C for industrial use only.

✓ Installation & Priming
Not self-priming; fill the pump casing and suction pipe with water before starting.
Use suitable inlet valves to retain prime in suction-lift installations; check the suction conditions against the pump curve.
Install on a firm base with supported pipework, drainage and protection from weather and freezing.
Leave at least 100mm clearance at the motor cooling fan, following the manual.
Provide suitable protection against loss of water supply; do not run dry.

✓ Construction
304 stainless-steel pump body, impellers and diffusers.
Standard MH3/MH5 seal: ceramic/carbon with EPDM elastomer.
Horizontal close-coupled multistage construction.

✓ Electrical Supply & Protection
Single phase: 220–240V, 50Hz, with AU/NZ plug and built-in thermal overload protection.
Three phase: 380–415V, 50Hz; requires external overload protection and connection by an electrician.
Maximum ambient temperature: 40°C.
Motor insulation: Class F. Refer to the supplied motor nameplate for its enclosure rating, output and current.
Franklin MultiStage Transfer Pump-5AMH5B-51, 83 LPM, 1.1KW - Single Phase

Franklin MH5 horizontal multistage pumps supply clean water for water transfer, pressure boosting, irrigation and washdown. Choose the stage count for the required flow and pressure, then select single-phase or three-phase supply.

These listings are for bare pump-and-motor units. Suitable separate controls are required for automatic operation as taps open and close; a pressure tank is not included.

5AMH2B: 75LPM at 15m head; maximum head 23.5m.
5AMH3B: 75LPM at 21.3m head; maximum head 34.8m.
5AMH4B: 75LPM at 28.4m head; maximum head 46.2m.
5AMH5B: 75LPM at 34m head; maximum head 57.3m.
5AMH6B: 75LPM at 43.2m head; maximum head 69.5m.
5AMH7B: 75LPM at 49.2m head; maximum head 80.7m.
5AMH8B: 75LPM at 60.6m head; maximum head 93.9m.
5AMH9B: 75LPM at 67.4m head; maximum head 105.4m.

The paired figures show flow at a stated head. Maximum head occurs at zero flow, separately from the listed flow. Allow for inlet conditions, height differences and pipe losses when selecting the pump.

Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.

The pump body, impellers and diffusers are 304 stainless steel. Use clean water without solid particles or fibres, compatible with the pump materials. Maximum water temperature is 55°C for single-phase models and 85°C for three-phase models in domestic and commercial use. The higher 110°C three-phase limit is for industrial applications only.

The pump is not self-priming. Fill the pump casing and suction pipe before starting, and use suitable inlet valves to retain prime where suction lift is required. Install on a firm base with drainage, supported pipework, ventilation and protection from weather and freezing. Do not run without water or against a closed outlet.

Maximum operating pressure is 1000kPa; inlet pressure and the pressure added by the pump must remain within this limit.

Single-phase versions use a 220–240V, 50Hz supply, have an AU/NZ plug and include motor thermal overload protection. Three-phase versions use a 380–415V, 50Hz supply and require an electrician connection and external motor protection.

Two-year Franklin Electric pump warranty, subject to its terms.

Franklin MH Pump Installation & Operating Manual

✓ Application
Clean-water transfer, pressure boosting, domestic water supply, garden irrigation and washdown.

✓ Warranty
Two-year Franklin Electric pump warranty, subject to its terms.

✓ Model Specifications
5AMH2B
Flow/head reference: 75LPM at 15m head.
Maximum pump head: 23.5m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 5AMH2B-51 single phase, 5AMH2B-53 three phase.

5AMH3B
Flow/head reference: 75LPM at 21.3m head.
Maximum pump head: 34.8m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 5AMH3B-51 single phase, 5AMH3B-53 three phase.
Single-phase motor output P2: 0.55kW.

5AMH4B
Flow/head reference: 75LPM at 28.4m head.
Maximum pump head: 46.2m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 5AMH4B-51 single phase, 5AMH4B-53 three phase.

5AMH5B
Flow/head reference: 75LPM at 34m head.
Maximum pump head: 57.3m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 5AMH5B-51 single phase, 5AMH5B-53 three phase.
Motor output P2: 1.1kW for the listed versions.

5AMH6B
Flow/head reference: 75LPM at 43.2m head.
Maximum pump head: 69.5m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 5AMH6B-51 single phase, 5AMH6B-53 three phase.

5AMH7B
Flow/head reference: 75LPM at 49.2m head.
Maximum pump head: 80.7m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 5AMH7B-51 single phase, 5AMH7B-53 three phase.
Motor output P2: 1.5kW for the listed versions.

5AMH8B
Flow/head reference: 75LPM at 60.6m head.
Maximum pump head: 93.9m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 5AMH8B-51 single phase, 5AMH8B-53 three phase.

5AMH9B
Flow/head reference: 75LPM at 67.4m head.
Maximum pump head: 105.4m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 5AMH9B-53 three phase.

✓ Supplied Operation
Bare pump-and-motor unit; pressure tank and automatic demand controls are supplied separately.
The pump does not automatically start and stop as taps open and close without suitable separate controls.

✓ Performance & Pressure Limits
The paired figures show the flow available at a stated head.
Application flow range: 33.3–116.7LPM; select the stage count for the required head.
Maximum head is the zero-flow figure and occurs separately from the listed flow.
Maximum operating pressure: 1000kPa. Inlet pressure plus pump pressure must remain within this limit.
Select the pump for the required flow and head, allowing for height differences and pipe losses.
Do not run against a closed outlet or below the manufacturer's minimum operating flow.

✓ Water Supply
Clean, non-aggressive liquids compatible with the pump materials, without solids or fibres.
Maximum water temperature: single phase 55°C; three phase 85°C for domestic/commercial use, or 110°C for industrial use only.

✓ Installation & Priming
Not self-priming; fill the pump casing and suction pipe with water before starting.
Use suitable inlet valves to retain prime in suction-lift installations; check the suction conditions against the pump curve.
Install on a firm base with supported pipework, drainage and protection from weather and freezing.
Leave at least 100mm clearance at the motor cooling fan, following the manual.
Provide suitable protection against loss of water supply; do not run dry.

✓ Construction
304 stainless-steel pump body, impellers and diffusers.
Standard MH3/MH5 seal: ceramic/carbon with EPDM elastomer.
Horizontal close-coupled multistage construction.

✓ Electrical Supply & Protection
Single phase: 220–240V, 50Hz, with AU/NZ plug and built-in thermal overload protection.
Three phase: 380–415V, 50Hz; requires external overload protection and connection by an electrician.
Maximum ambient temperature: 40°C.
Motor insulation: Class F. Refer to the supplied motor nameplate for its enclosure rating, output and current.
Franklin MultiStage Transfer Pump-9AMH2B-51, 150LPM, 0.75KW - Single Phase

Franklin MH9 horizontal multistage pumps supply clean water for water transfer, pressure boosting, irrigation and washdown. Choose the stage count for the required flow and pressure, then select single-phase or three-phase supply.

Suitable uses include domestic and commercial water supply, light industrial water transfer and compatible circulation systems. Supplied as a bare pump-and-motor unit. Suitable separate controls are required for automatic operation as taps open and close; a pressure tank is not included.

9AMH2B: 166.7LPM at 15.6m head; maximum head 23.7m.
9AMH3B: 166.7LPM at 22.8m head; maximum head 35.3m.
9AMH4B: 166.7LPM at 31.7m head; maximum head 47.4m.
9AMH5B: 166.7LPM at 42.1m head; maximum head 60.1m.
9AMH6B: 166.7LPM at 49.5m head; maximum head 71.8m.

The paired figures show flow and head together; they are reference points, not maximum-flow ratings or a nominated ideal duty. Maximum head occurs at zero flow. Allow for inlet conditions, height differences and pipe losses when selecting the pump.

Inlet: 1 1/2" BSP female thread.
Outlet: 1 1/4" BSP female thread.

The pump body, impellers and diffusers are 304 stainless steel. Use clean water without solids or fibres, compatible with the pump materials. Maximum water temperature is 55°C for single-phase models and 85°C for three-phase models in domestic and commercial use. The higher 110°C three-phase limit is for industrial applications only.

The pump is not self-priming. Fill the pump casing and suction pipe before starting, and use suitable inlet valves to retain prime where suction lift is required. Install on a firm base with drainage, supported pipework, ventilation and protection from weather and freezing. Do not run without water or against a closed outlet.

Maximum operating pressure is 1000kPa; inlet pressure and the pressure added by the pump must remain within this limit.

Single-phase versions use a 220–240V, 50Hz supply, have an AU/NZ plug and include motor thermal overload protection. Three-phase versions use a 380–415V, 50Hz supply and require connection by an electrician and external motor overload protection.

Pump covers are available separately; check clearance and ventilation for the selected pump.

Two-year Franklin Electric pump warranty, subject to its terms.

Franklin MH Pump Installation & Operating Manual

✓ Application
Clean-water transfer, pressure boosting, domestic and commercial water supply, irrigation, washdown and compatible circulation systems, including light industrial applications.

✓ Warranty
Two-year Franklin Electric pump warranty, subject to its terms.

✓ Model Specifications
9AMH2B
Flow/head reference: 166.7LPM at 15.6m head.
Maximum pump head: 23.7m (zero flow).
Inlet: 1 1/2" BSP female thread.
Outlet: 1 1/4" BSP female thread.
Stocked versions: 9AMH2B-51 single phase, 9AMH2B-53 three phase.
Motor output P2: 0.75kW for the listed versions.

9AMH3B
Flow/head reference: 166.7LPM at 22.8m head.
Maximum pump head: 35.3m (zero flow).
Inlet: 1 1/2" BSP female thread.
Outlet: 1 1/4" BSP female thread.
Stocked versions: 9AMH3B-51 single phase, 9AMH3B-53 three phase.
Motor output P2: 1.1kW for the listed versions.

9AMH4B
Flow/head reference: 166.7LPM at 31.7m head.
Maximum pump head: 47.4m (zero flow).
Inlet: 1 1/2" BSP female thread.
Outlet: 1 1/4" BSP female thread.
Stocked versions: 9AMH4B-51 single phase, 9AMH4B-53 three phase.
Motor output P2: 1.5kW for the listed versions.

9AMH5B
Flow/head reference: 166.7LPM at 42.1m head.
Maximum pump head: 60.1m (zero flow).
Inlet: 1 1/2" BSP female thread.
Outlet: 1 1/4" BSP female thread.
Stocked versions: 9AMH5B-53 three phase.

9AMH6B
Flow/head reference: 166.7LPM at 49.5m head.
Maximum pump head: 71.8m (zero flow).
Inlet: 1 1/2" BSP female thread.
Outlet: 1 1/4" BSP female thread.
Stocked versions: 9AMH6B-53 three phase.

✓ Supplied Operation
Bare pump-and-motor unit; pressure tank and automatic demand controls are supplied separately.
The pump does not automatically start and stop as taps open and close without suitable separate controls.

✓ Performance & Pressure Limits
The paired figures show the flow available at a stated head.
Application flow range: 50–233.3LPM; select the stage count for the required head.
Maximum head is the zero-flow figure and occurs separately from the listed flow.
Maximum operating pressure: 1000kPa. Inlet pressure plus pump pressure must remain within this limit.
Select for the required flow and head, allowing for height differences and pipe losses.
Do not run against a closed outlet or below the manufacturer's minimum operating flow.

✓ Water Supply
Clean, non-aggressive liquids compatible with the pump materials, without solids or fibres.
Maximum water temperature: single phase 55°C; three phase 85°C for domestic/commercial use, or 110°C for industrial use only.

✓ Installation & Priming
Not self-priming; fill the pump casing and suction pipe with water before starting.
Use suitable inlet valves to retain prime in suction-lift installations; check suction conditions against the pump curve.
Install horizontally on a firm base with supported pipework, drainage and protection from weather and freezing.
Leave at least 100mm clearance at the motor cooling fan, following the manual.
Provide suitable protection against loss of water supply; do not run dry.

✓ Construction
304 stainless-steel pump body, impellers and diffusers.
Ceramic/carbon mechanical seal with EPDM elastomer.
Horizontal close-coupled multistage construction.

✓ Electrical Supply & Protection
Single phase: 220–240V, 50Hz, with AU/NZ plug and built-in motor thermal overload protection.
Three phase: 380–415V, 50Hz; external overload protection and connection by an electrician required.
Maximum ambient temperature: 40°C.
Motor insulation: Class F. Refer to the supplied motor nameplate for its enclosure rating, output and current.
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-15AMH7B-53 PUFR96140015307
$2,986.83 /each
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-15AMH2B-53 PUFR96140015302
$1,524.60 /each
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-15AMH3B-53 PUFR96140015303
$1,711.71 /each
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-15AMH4B-53 PUFR96140015304
$1,947.33 /each
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-15AMH5B-53 PUFR96140015305
$2,290.37 /each
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-15AMH6B-53 PUFR96140015306
$2,844.77 /each

Franklin MH15 horizontal multistage pumps supply clean water for pressure boosting, water transfer, irrigation and washdown.

Suitable applications include commercial, agricultural and industrial water distribution and compatible circulation systems.

Supplied as a bare pump-and-motor unit. Automatic start/stop operation requires a suitable separate controller; a pressure tank is not included.

15AMH2B-53: 283.3LPM at 19.2m head; maximum head 28.5m; 1.5kW motor.
15AMH3B-53: 283.3LPM at 29.9m head; maximum head 43.3m; 2.2kW motor.
15AMH4B-53: 283.3LPM at 40.3m head; maximum head 57.9m; 3kW motor.
15AMH5B-53: 283.3LPM at 50.8m head; maximum head 72.6m; 4kW motor.
15AMH6B-53: 283.3LPM at 62.1m head; maximum head 87.5m; 5.5kW motor.
15AMH7B-53: 283.3LPM at 71.7m head; maximum head 101.9m; 5.5kW motor.

The paired figures show flow and head together; they are reference points, not maximum-flow ratings or a nominated ideal duty. Maximum head occurs at zero flow. Allow for inlet conditions, height differences and pipe losses when selecting the pump.

Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.

The pump body, impellers and diffusers are 304 stainless steel, with reinforced tie-rod construction and a carbon/silicon-carbide mechanical seal with EPDM elastomer. Use clean water without solids or fibres, compatible with the pump materials. Maximum water temperature is 85°C for domestic and commercial use; the 110°C limit is for industrial applications only.

The pump is not self-priming. Fill the pump casing and suction pipe before starting, and use suitable inlet valves to retain prime where suction lift is required. Install on a firm base with drainage, supported pipework, ventilation and protection from weather and freezing. Do not run without water or against a closed outlet.

Maximum operating pressure is 1000kPa; inlet pressure and the pressure added by the pump must remain within this limit.

The stocked versions use a 380–415V three-phase, 50Hz supply. Connection by an electrician and suitable external motor overload protection are required.

Two-year Franklin Electric pump warranty, subject to its terms.

Franklin MH Pump Installation & Operating Manual

✓ Application
Clean-water transfer, pressure boosting, irrigation, water distribution, washdown and compatible circulation systems for commercial, agricultural and industrial use.

✓ Warranty
Two-year Franklin Electric pump warranty, subject to its terms.

✓ Model Specifications
15AMH2B-53
Flow/head reference: 283.3LPM at 19.2m head.
Maximum pump head: 28.5m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 1.5kW.
Power supply: 380–415V three phase, 50Hz.

15AMH3B-53
Flow/head reference: 283.3LPM at 29.9m head.
Maximum pump head: 43.3m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 2.2kW.
Power supply: 380–415V three phase, 50Hz.

15AMH4B-53
Flow/head reference: 283.3LPM at 40.3m head.
Maximum pump head: 57.9m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 3kW.
Power supply: 380–415V three phase, 50Hz.

15AMH5B-53
Flow/head reference: 283.3LPM at 50.8m head.
Maximum pump head: 72.6m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 4kW.
Power supply: 380–415V three phase, 50Hz.

15AMH6B-53
Flow/head reference: 283.3LPM at 62.1m head.
Maximum pump head: 87.5m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 5.5kW.
Power supply: 380–415V three phase, 50Hz.

15AMH7B-53
Flow/head reference: 283.3LPM at 71.7m head.
Maximum pump head: 101.9m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 5.5kW.
Power supply: 380–415V three phase, 50Hz.

✓ Supplied Operation
One bare pump-and-motor unit; pressure tank and automatic demand controls are supplied separately.
The pump does not automatically start and stop as taps open and close without suitable separate controls.

✓ Performance & Pressure Limits
The paired figures show flow available at a stated head.
Application flow range: 133.3–400LPM; select the stage count for the required head.
Maximum head is the zero-flow figure and occurs separately from the listed flow.
Maximum operating pressure: 1000kPa. Inlet pressure plus the pressure added by the pump must remain within this limit.
Select for the required flow and head, allowing for height differences and pipe losses.
Do not run against a closed outlet or below the manufacturer's minimum operating flow.

✓ Water Supply
Clean, non-aggressive liquids compatible with the pump materials, without solids or fibres.
Maximum water temperature: 85°C for domestic/commercial use; 110°C for industrial use only.

✓ Installation & Priming
Not self-priming; fill the pump casing and suction pipe with water before starting.
Check suction conditions against the performance curve; use suitable inlet valves to retain prime where suction lift is required.
Install horizontally on a firm base with supported pipework, drainage and protection from weather and freezing.
Leave at least 100mm clearance at the motor cooling fan, following the manual.
Provide suitable protection against loss of water supply; do not run dry.

✓ Construction
304 stainless-steel pump body, impellers and diffusers.
Reinforced tie-rod construction and heavy-duty motor shaft.
Carbon/silicon-carbide mechanical seal with EPDM elastomer.

✓ Electrical Supply & Protection
380–415V three phase, 50Hz; connection by an electrician required.
External motor overload protection required; do not assume built-in overload or dry-run protection.
Maximum ambient temperature: 40°C.
Motor enclosure: IP55. Insulation: Class F.
Select wiring and motor protection to match the supplied motor nameplate.
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-20AMH5B-53 PUFR96140020305
$2,706.17 /each
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-20AMH2B-53 PUFR96140020302
$1,649.34 /each
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-20AMH3B-53 PUFR96140020303
$1,808.73 /each
Franklin MH15/MH20 bare pump range; each listing supplies one pump. Stage count and motor size vary.
Franklin MultiStage Transfer Pump-20AMH4B-53 PUFR96140020304
$2,068.61 /each

Franklin MH20 horizontal multistage pumps supply clean water for pressure boosting, water transfer, irrigation and washdown.

Suitable applications include commercial, agricultural and industrial water distribution and compatible circulation systems.

Supplied as a bare pump-and-motor unit. Automatic start/stop operation requires a suitable separate controller; a pressure tank is not included.

20AMH2B-53: 333.3LPM at 23.1m head; maximum head 31.2m; 2.2kW motor.
20AMH3B-53: 333.3LPM at 34.6m head; maximum head 46.8m; 3kW motor.
20AMH4B-53: 333.3LPM at 46.3m head; maximum head 62.5m; 4kW motor.
20AMH5B-53: 333.3LPM at 58.9m head; maximum head 78.5m; 5.5kW motor.

The paired figures show flow and head together; they are reference points, not maximum-flow ratings or a nominated ideal duty. Maximum head occurs at zero flow. Allow for inlet conditions, height differences and pipe losses when selecting the pump.

Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.

The pump body, impellers and diffusers are 304 stainless steel, with reinforced tie-rod construction and a carbon/silicon-carbide mechanical seal with EPDM elastomer. Use clean water without solids or fibres, compatible with the pump materials. Maximum water temperature is 85°C for domestic and commercial use; the 110°C limit is for industrial applications only.

The pump is not self-priming. Fill the pump casing and suction pipe before starting, and use suitable inlet valves to retain prime where suction lift is required. Install on a firm base with drainage, supported pipework, ventilation and protection from weather and freezing. Do not run without water or against a closed outlet.

Maximum operating pressure is 1000kPa; inlet pressure and the pressure added by the pump must remain within this limit.

The stocked versions use a 380–415V three-phase, 50Hz supply. Connection by an electrician and suitable external motor overload protection are required.

Two-year Franklin Electric pump warranty, subject to its terms.

Franklin MH Pump Installation & Operating Manual

✓ Application
Clean-water transfer, pressure boosting, irrigation, water distribution, washdown and compatible circulation systems for commercial, agricultural and industrial use.

✓ Warranty
Two-year Franklin Electric pump warranty, subject to its terms.

✓ Model Specifications
20AMH2B-53
Flow/head reference: 333.3LPM at 23.1m head.
Maximum pump head: 31.2m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 2.2kW.
Power supply: 380–415V three phase, 50Hz.

20AMH3B-53
Flow/head reference: 333.3LPM at 34.6m head.
Maximum pump head: 46.8m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 3kW.
Power supply: 380–415V three phase, 50Hz.

20AMH4B-53
Flow/head reference: 333.3LPM at 46.3m head.
Maximum pump head: 62.5m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 4kW.
Power supply: 380–415V three phase, 50Hz.

20AMH5B-53
Flow/head reference: 333.3LPM at 58.9m head.
Maximum pump head: 78.5m (zero flow).
Inlet: 2" BSP female thread.
Outlet: 1 1/2" BSP female thread.
Motor output P2: 5.5kW.
Power supply: 380–415V three phase, 50Hz.

✓ Supplied Operation
One bare pump-and-motor unit; pressure tank and automatic demand controls are supplied separately.
The pump does not automatically start and stop as taps open and close without suitable separate controls.

✓ Performance & Pressure Limits
The paired figures show flow available at a stated head.
Application flow range: 166.7–466.7LPM; select the stage count for the required head.
Maximum head is the zero-flow figure and occurs separately from the listed flow.
Maximum operating pressure: 1000kPa. Inlet pressure plus the pressure added by the pump must remain within this limit.
Select for the required flow and head, allowing for height differences and pipe losses.
Do not run against a closed outlet or below the manufacturer's minimum operating flow.

✓ Water Supply
Clean, non-aggressive liquids compatible with the pump materials, without solids or fibres.
Maximum water temperature: 85°C for domestic/commercial use; 110°C for industrial use only.

✓ Installation & Priming
Not self-priming; fill the pump casing and suction pipe with water before starting.
Check suction conditions against the performance curve; use suitable inlet valves to retain prime where suction lift is required.
Install horizontally on a firm base with supported pipework, drainage and protection from weather and freezing.
Leave at least 100mm clearance at the motor cooling fan, following the manual.
Provide suitable protection against loss of water supply; do not run dry.

✓ Construction
304 stainless-steel pump body, impellers and diffusers.
Reinforced tie-rod construction and heavy-duty motor shaft.
Carbon/silicon-carbide mechanical seal with EPDM elastomer.

✓ Electrical Supply & Protection
380–415V three phase, 50Hz; connection by an electrician required.
External motor overload protection required; do not assume built-in overload or dry-run protection.
Maximum ambient temperature: 40°C.
Motor enclosure: IP55. Insulation: Class F.
Select wiring and motor protection to match the supplied motor nameplate.
Seaflo AG WPS Pump 21 Series 12V 4L/PM
Seaflo AG WPS Pump 21 Series 12V 4L/PM
Seaflo AG WPS Pump 21 Series 12V 4L/PM PUMP-SFADP1-011-070-21
$102.49 /each

The Seaflo AG 21 is a compact 12V DC diaphragm pump for agricultural spraying and compatible liquid transfer. Its built-in pressure switch starts the pump as system pressure falls and stops it when shutoff pressure is reached.

The pump has Viton valves and a Santoprene diaphragm. Check compatibility with the intended liquid, concentration and temperature before using agricultural chemicals. The valve material does not establish compatibility with every chemical.

Maximum open flow is 4LPM. The pressure switch stops the pump at 70psi (about 480kPa). These figures are separate limits: flow decreases as pressure rises, and the pump does not deliver its maximum flow at shutoff pressure.

Inlet: 10mm (3/8") hose barb.
Outlet: 10mm (3/8") hose barb.

The automatic pressure switch provides demand operation as an outlet opens and closes. Consult Seaflo before changing the preset pressure, as changes may affect the warranty.

The pump is self-priming with a suction lift up to 1.2m. Actual lift depends on the inlet hose, air leaks and the liquid being pumped. Brief dry-running capability does not provide automatic shutdown when a tank is empty; switch off when the liquid supply runs out.

Use intermittently, allowing the motor to cool between runs. Use liquid at temperatures up to 60°C, subject to chemical compatibility. Mount the pump securely using its rubber feet without overtightening them, and fit a suitable inlet strainer. Use flexible reinforced hose and keep the motor and electrical connections protected from water.

The pump requires a 12V DC supply. Maximum current is 4A. It is supplied with two-pin leads.

Two-year warranty, subject to its terms.

Seaflo 21 Series Installation Manual

✓ Application
Agricultural spraying, compatible liquid transfer, circulation, filtration and dispensing in fixed or mobile equipment.

✓ Warranty
Two-year warranty, subject to its terms.

✓ Model Specifications
SFADP1-011-070-21
Maximum open flow: 4LPM.
Preset shutoff pressure: 70psi (about 480kPa).
Inlet: 10mm (3/8") hose barb.
Outlet: 10mm (3/8") hose barb.
Power supply: 12V DC.
Maximum current: 4A.
Maximum recommended liquid temperature: 60°C.

✓ Pressure Control & Performance
Automatic pressure switch starts the pump as pressure falls and stops it at shutoff pressure.
Maximum flow and shutoff pressure are separate operating limits; flow decreases as pressure increases.
Consult Seaflo before changing the preset pressure, as changes may affect the warranty.

✓ Duty
Intermittent duty: allow cooling breaks between runs.

✓ Liquid Compatibility
Viton valves and Santoprene diaphragm.
Check the intended liquid, concentration and temperature against all wetted materials before use.
Agricultural valve material does not establish approval for every chemical, drinking-water or food application.

✓ Installation & Operation
Self-priming: suction lift up to 1.2m; usable lift depends on inlet conditions and hose losses.
Dry-running capability is not automatic dry-run shutdown. Switch off when the liquid supply runs out.
Fit a suitable inlet strainer and flexible reinforced hose; keep suction joints airtight.
Secure rubber mounting feet without overtightening them.
Protect the motor and electrical connections from water.

✓ Construction
Two-chamber positive-displacement diaphragm pump.
Viton valves; Santoprene diaphragm.
Rubber mounting feet help reduce vibration transmission.

✓ Electrical Supply
12V DC.
Two-pin leads.

✓ Product Identification
Model: SFADP1-011-070-21.
Stock SKU: PUMP-SFADP1-011-070-21.
Seaflo AG WPS Pump 22 Series 12V 5L/PM
Seaflo AG WPS Pump 22 Series 12V 5L/PM
Seaflo AG WPS Pump 22 Series 12V 5L/PM PUMP-SFADP1-013-100-22
$132.57 /each

The Seaflo AG 22 is a compact 12V DC diaphragm pump for agricultural spraying and compatible liquid transfer. Its built-in pressure switch starts the pump as system pressure falls and stops it when shutoff pressure is reached. An internal bypass helps reduce rapid on/off cycling.

The pump has Viton valves and a Santoprene diaphragm. Check compatibility with the intended liquid, concentration and temperature before using agricultural chemicals. The valve material does not establish compatibility with every chemical.

Maximum open flow is 5LPM. The pressure switch stops the pump at 100psi (about 690kPa). These figures are separate limits: flow decreases as pressure rises, and the pump does not deliver its maximum flow at shutoff pressure.

Inlet: 10mm (3/8") hose barb.
Outlet: 10mm (3/8") hose barb.

The automatic pressure switch provides demand operation as an outlet opens and closes. The internal bypass recirculates some liquid within the pump at low demand, helping reduce rapid switching. Consult Seaflo before changing the preset pressure, as changes may affect the warranty.

The pump is self-priming with a suction lift up to 1.2m. Actual lift depends on the inlet hose, air leaks and the liquid being pumped. Brief dry-running capability does not provide automatic shutdown when a tank is empty; switch off when the liquid supply runs out.

Use according to the duty-cycle instructions supplied with the pump. Use liquid at temperatures up to 60°C, subject to chemical compatibility. Mount the pump securely using its rubber feet without overtightening them, and fit a suitable inlet strainer. Use flexible reinforced hose and keep the motor and electrical connections protected from water.

The pump requires a 12V DC supply. Maximum current is 5A. It is supplied with two-pin leads.

Two-year warranty, subject to its terms.

Seaflo AG 22 Series Specifications

✓ Application
Agricultural spraying, compatible liquid transfer, circulation, filtration and dispensing in fixed or mobile equipment.

✓ Warranty
Two-year warranty, subject to its terms.

✓ Model Specifications
SFADP1-013-100-22
Maximum open flow: 5LPM.
Preset shutoff pressure: 100psi (about 690kPa).
Inlet: 10mm (3/8") hose barb.
Outlet: 10mm (3/8") hose barb.
Power supply: 12V DC.
Maximum current: 5A.
Maximum recommended liquid temperature: 60°C.

✓ Pressure Control & Performance
Automatic pressure switch starts the pump as pressure falls and stops it at shutoff pressure.
Maximum flow and shutoff pressure are separate operating limits; flow decreases as pressure increases.
Consult Seaflo before changing the preset pressure, as changes may affect the warranty.
Internal bypass helps reduce rapid cycling at low demand.
Restart pressure: 75psi ±5psi for the 100psi configuration.

✓ Duty
Follow the duty-cycle instructions supplied with the pump.

✓ Liquid Compatibility
Viton valves and Santoprene diaphragm.
Check the intended liquid, concentration and temperature against all wetted materials before use.
Agricultural valve material does not establish approval for every chemical, drinking-water or food application.

✓ Installation & Operation
Self-priming: suction lift up to 1.2m; usable lift depends on inlet conditions and hose losses.
Dry-running capability is not automatic dry-run shutdown. Switch off when the liquid supply runs out.
Fit a suitable inlet strainer and flexible reinforced hose; keep suction joints airtight.
Secure rubber mounting feet without overtightening them.
Protect the motor and electrical connections from water.

✓ Construction
Two-chamber positive-displacement diaphragm pump.
Viton valves; Santoprene diaphragm.
Rubber mounting feet help reduce vibration transmission.

✓ Electrical Supply
12V DC.
Two-pin leads.

✓ Product Identification
Model: SFADP1-013-100-22.
Stock SKU: PUMP-SFADP1-013-100-22.
Seaflo AG WPS Pump 35 Series 12V 7L/PM
Seaflo AG WPS Pump 35 Series 12V 7L/PM
Seaflo AG WPS Pump 35 Series 12V 7L/PM PUMP-SFADP1-018-120-35
$312.26 /each

The Seaflo AG 35 is a 12V DC diaphragm pump for agricultural spraying and compatible liquid transfer. Its built-in pressure switch starts the pump as system pressure falls and stops it when shutoff pressure is reached.

The pump is supplied with two-pin leads. Use Seaflo Quick Attach fittings matched to the pump ports to connect the inlet and outlet hoses.

Maximum open flow is 7LPM. The pressure switch stops the pump at 120psi (about 830kPa). These are separate limits: flow decreases as pressure rises, and the pump does not deliver its maximum flow at shutoff pressure.

Inlet: 16mm (5/8") Seaflo Quick Attach port.
Outlet: 16mm (5/8") Seaflo Quick Attach port.

Viton valves and a Santoprene diaphragm suit compatible agricultural liquids. Check the liquid, concentration and temperature against all wetted materials before pumping chemicals. The valve material does not establish compatibility with every chemical or approval for drinking-water and food applications.

The three-chamber diaphragm design provides automatic demand operation for moderate-flow, higher-pressure spraying and transfer systems. Keep the supplied pressure setting; refer any setting change to Seaflo.

The pump is self-priming with a suction lift up to 1.8m. Usable lift depends on the inlet hose, air leaks and the liquid being pumped. Dry-running capability does not provide automatic shutdown when a tank is empty; switch off when the liquid supply runs out.

Continuous duty; follow the operating limits in the supplied instructions. Use liquid at temperatures up to 60°C, subject to chemical compatibility.

Fit a suitable inlet strainer and flexible reinforced hose, keeping suction joints airtight. Secure the pump using its rubber mounting feet without overtightening them, and protect the motor and electrical connections from water.

The pump requires a 12V DC supply. Maximum current is 12A.

Two-year warranty, subject to its terms.

Seaflo AG 35 Series Specifications

✓ Application
Agricultural spraying, compatible liquid transfer, circulation, filtration and dispensing in fixed or mobile equipment.

✓ Warranty
Two-year warranty, subject to its terms.

✓ Model Specifications
SFADP1-018-120-35
Maximum open flow: 7LPM.
Preset shutoff pressure: 120psi (about 830kPa).
Inlet: 16mm (5/8") Seaflo Quick Attach port.
Outlet: 16mm (5/8") Seaflo Quick Attach port.
Power supply: 12V DC.
Maximum current: 12A.
Maximum recommended liquid temperature: 60°C.

✓ Supplied Equipment
Supplied with two-pin leads. Use Seaflo Quick Attach fittings matched to the pump ports to connect the inlet and outlet hoses.

✓ Pressure Control & Performance
Automatic pressure switch starts the pump as pressure falls and stops it at shutoff pressure.
Maximum flow and shutoff pressure are separate limits; flow decreases as pressure increases.
Keep the supplied pressure setting; refer setting changes to Seaflo.

✓ Duty
Continuous duty; follow the operating limits in the supplied instructions.

✓ Liquid Compatibility
Viton valves and Santoprene diaphragm.
Check the intended liquid, concentration and temperature against all wetted materials before use.
Agricultural valve material does not establish approval for every chemical, drinking-water or food application.

✓ Installation & Operation
Self-priming: suction lift up to 1.8m; usable lift depends on inlet conditions and hose losses.
Dry-running capability is not automatic dry-run shutdown. Switch off when the liquid supply runs out.
Fit a suitable inlet strainer and flexible reinforced hose; keep suction joints airtight.
Secure rubber mounting feet without overtightening them.
Protect the motor and electrical connections from water.

✓ Construction
3-chamber positive-displacement diaphragm pump.
Viton valves; Santoprene diaphragm.
Rubber mounting feet help reduce vibration transmission.

✓ Electrical Supply
12V DC.
Two-pin leads.

✓ Dimensions & Weight
Overall dimensions: 210mm long x 102.5mm wide x 114.5mm high.
Net weight: 2.3kg.

✓ Product Identification
Model: SFADP1-018-120-35.
Stock SKU: PUMP-SFADP1-018-120-35.
Seaflo AG WPS Pump 51 Series 12V 11.5L/PM
Seaflo AG WPS Pump 51 Series 12V 11.5L/PM
Seaflo AG WPS Pump 51 Series 12V 11.5L/PM PUMP-SFADP1-030-060-51
$290.60 /each

The Seaflo AG 51 is a 12V DC diaphragm pump for agricultural spraying and compatible liquid transfer. Its built-in pressure switch starts the pump as system pressure falls and stops it when shutoff pressure is reached.

The pump is supplied with two 1/2" female NPT x 1/2" hose-barb fittings and two-pin leads.

Maximum open flow is 11.5LPM. The pressure switch stops the pump at 60psi (about 410kPa). These are separate limits: flow decreases as pressure rises, and the pump does not deliver its maximum flow at shutoff pressure.

Inlet: 1/2" male NPT thread.
Outlet: 1/2" male NPT thread.

Viton valves and a Santoprene diaphragm suit compatible agricultural liquids. Check the liquid, concentration and temperature against all wetted materials before pumping chemicals. The valve material does not establish compatibility with every chemical or approval for drinking-water and food applications.

The five-chamber diaphragm design helps smooth the flow and reduce cycling. The pressure switch provides automatic demand operation as an outlet opens and closes.

Supplied with the pressure switch preset to 60psi. Consult Seaflo before changing the setting, as changes may affect the warranty.

The pump is self-priming with a suction lift up to 1.8m. Usable lift depends on the inlet hose, air leaks and the liquid being pumped. Dry-running capability does not provide automatic shutdown when a tank is empty; switch off when the liquid supply runs out.

Follow the duty-cycle instructions supplied with the pump. Use liquid at temperatures up to 60°C, subject to chemical compatibility.

Fit a suitable inlet strainer and flexible reinforced hose, keeping suction joints airtight. Secure the pump using its rubber mounting feet without overtightening them, and protect the motor and electrical connections from water.

The pump requires a 12V DC supply. Maximum current is 10A.

Two-year warranty, subject to its terms.

Seaflo AG 51 Series Specifications

✓ Application
Agricultural spraying, compatible liquid transfer, circulation, filtration and dispensing in fixed or mobile equipment.

✓ Warranty
Two-year warranty, subject to its terms.

✓ Model Specifications
SFADP1-030-060-51
Maximum open flow: 11.5LPM.
Preset shutoff pressure: 60psi (about 410kPa).
Inlet: 1/2" male NPT thread.
Outlet: 1/2" male NPT thread.
Power supply: 12V DC.
Maximum current: 10A.
Maximum recommended liquid temperature: 60°C.

✓ Supplied Equipment
Supplied with two 1/2" female NPT x 1/2" hose-barb fittings and two-pin leads.

✓ Pressure Control & Performance
Automatic pressure switch starts the pump as pressure falls and stops it at shutoff pressure.
Maximum flow and shutoff pressure are separate limits; flow decreases as pressure increases.
Keep the supplied pressure setting; refer setting changes to Seaflo.
Restart pressure: 48psi ±5psi for the 60psi configuration.

✓ Duty
Follow the duty-cycle instructions supplied with the pump.

✓ Liquid Compatibility
Viton valves and Santoprene diaphragm.
Check the intended liquid, concentration and temperature against all wetted materials before use.
Agricultural valve material does not establish approval for every chemical, drinking-water or food application.

✓ Installation & Operation
Self-priming: suction lift up to 1.8m; usable lift depends on inlet conditions and hose losses.
Dry-running capability is not automatic dry-run shutdown. Switch off when the liquid supply runs out.
Fit a suitable inlet strainer and flexible reinforced hose; keep suction joints airtight.
Secure rubber mounting feet without overtightening them.
Protect the motor and electrical connections from water.

✓ Construction
5-chamber positive-displacement diaphragm pump.
Viton valves; Santoprene diaphragm.
Rubber mounting feet help reduce vibration transmission.

✓ Electrical Supply
12V DC.
Two-pin leads.

✓ Dimensions & Weight
Overall dimensions: 216mm long x 146mm wide x 131mm high.
Net weight: 2.8kg.

✓ Product Identification
Model: SFADP1-030-060-51.
Stock SKU: PUMP-SFADP1-030-060-51.
Seaflo AG WPS Pump 55 Series 12V 18.9L/PM
Seaflo AG WPS Pump 55 Series 12V 18.9L/PM
Seaflo AG WPS Pump 55 Series 12V 18.9L/PM PUMP-SFADP1-050-060-55
$577.48 /each

The Seaflo AG 55 is a 12V DC diaphragm pump for agricultural spraying and compatible liquid transfer. Its built-in pressure switch starts the pump as system pressure falls and stops it when shutoff pressure is reached. An internal bypass helps reduce rapid on/off cycling at low demand.

The pump is supplied with two 1/2" female NPT x 1/2" hose-barb fittings and two-pin leads.

Maximum open flow is 18.9LPM. The pressure switch stops the pump at 60psi (about 410kPa). These are separate limits: flow decreases as pressure rises, and the pump does not deliver its maximum flow at shutoff pressure.

Inlet: 1/2" male NPT thread.
Outlet: 1/2" male NPT thread.

Viton valves and a Santoprene diaphragm suit compatible agricultural liquids. Check the liquid, concentration and temperature against all wetted materials before pumping chemicals. The valve material does not establish compatibility with every chemical or approval for drinking-water and food applications.

The five-chamber design and internal bypass help reduce rapid cycling at low demand. A separate accumulator tank is not required for normal operation. The number of outlets that can run together depends on their combined flow and pressure requirements.

Keep the supplied pressure setting. Refer pressure-switch and bypass adjustments to Seaflo; incorrect settings may prevent the pump from switching off or affect the warranty.

The pump is self-priming with a suction lift up to 1.8m. Usable lift depends on the inlet hose, air leaks and the liquid being pumped. Dry-running capability does not provide automatic shutdown when a tank is empty; switch off when the liquid supply runs out.

Follow the duty-cycle instructions supplied with the pump. Use liquid at temperatures up to 60°C, subject to chemical compatibility.

Fit a suitable inlet strainer and flexible reinforced hose, keeping suction joints airtight. Secure the pump using its rubber mounting feet without overtightening them, and protect the motor and electrical connections from water.

The pump requires a 12V DC supply. Maximum current is 17A.

Two-year warranty, subject to its terms.

Seaflo AG 55 Series Specifications

✓ Application
Agricultural spraying, compatible liquid transfer, circulation, filtration and dispensing in fixed or mobile equipment.

✓ Warranty
Two-year warranty, subject to its terms.

✓ Model Specifications
SFADP1-050-060-55
Maximum open flow: 18.9LPM.
Preset shutoff pressure: 60psi (about 410kPa).
Inlet: 1/2" male NPT thread.
Outlet: 1/2" male NPT thread.
Power supply: 12V DC.
Maximum current: 17A.
Maximum recommended liquid temperature: 60°C.

✓ Supplied Equipment
Supplied with two 1/2" female NPT x 1/2" hose-barb fittings and two-pin leads.

✓ Pressure Control & Performance
Automatic pressure switch starts the pump as pressure falls and stops it at shutoff pressure.
Maximum flow and shutoff pressure are separate limits; flow decreases as pressure increases.
Keep the supplied pressure setting; refer setting changes to Seaflo.
Restart pressure: 48psi ±5psi for the 60psi configuration.
Internal bypass helps reduce rapid cycling at low demand. A separate accumulator tank is not required for normal operation.
Available flow and pressure determine how many outlets can operate together.

✓ Duty
Follow the duty-cycle instructions supplied with the pump.

✓ Liquid Compatibility
Viton valves and Santoprene diaphragm.
Check the intended liquid, concentration and temperature against all wetted materials before use.
Agricultural valve material does not establish approval for every chemical, drinking-water or food application.

✓ Installation & Operation
Self-priming: suction lift up to 1.8m; usable lift depends on inlet conditions and hose losses.
Dry-running capability is not automatic dry-run shutdown. Switch off when the liquid supply runs out.
Fit a suitable inlet strainer and flexible reinforced hose; keep suction joints airtight.
Secure rubber mounting feet without overtightening them.
Protect the motor and electrical connections from water.

✓ Construction
5-chamber positive-displacement diaphragm pump.
Viton valves; Santoprene diaphragm.
Rubber mounting feet help reduce vibration transmission.

✓ Electrical Supply
12V DC.
Two-pin leads.

✓ Dimensions & Weight
Overall dimensions: 224mm long x 146mm wide x 131mm high.
Net weight: 2.8kg.

✓ Product Identification
Model: SFADP1-050-060-55.
Stock SKU: PUMP-SFADP1-050-060-55.
Seaflo AG ATV Spot Sprayer 50L SER22
Seaflo AG ATV Spot Sprayer 50L SER22
Seaflo AG ATV Spot Sprayer 50L SER22 PUMP-SFSP-050-013-01A
$327.98 /each
Seaflo 100L ATV spot sprayer with pump, hose and hand spray gun
Seaflo AG ATV Spot Sprayer 100L SER22 PUMP-SFSP-100-013-01A
$538.22 /each

The Seaflo AG ATV spot sprayers provide electric spot spraying for weed and pest control, fertiliser application and property maintenance. The tank, 12V diaphragm pump, hose and hand spray gun form a portable unit for mounting on an ATV, utility vehicle or trailer.

Choose the 50L SFSP-050-013-01A or 100L SFSP-100-013-01A to suit the required tank capacity.

The supplied equipment includes a 6m spray hose, stainless steel lance with adjustable nozzle, lance storage clips, water inlet filter and a 2.5m battery cable with a DC quick-plug and battery clips. The pump provides spraying without manual pumping.

Maximum pump flow is 5LPM. The pump pressure limit is 100psi (about 690kPa). Maximum flow and maximum pressure are separate limits; flow decreases as pressure rises, and actual delivery through the spray nozzle depends on its setting.

The 10mm internal-diameter spray hose is rated to 20bar (2000kPa). This is the hose rating, rather than the operating pressure of the sprayer.

The HDPE tank has a filling lid and carry handles. Filtration helps keep sediment out of the pump. Use liquids compatible with the complete sprayer and follow the chemical label for mixing and application.

Secure the unit to a suitable support and account for the filled tank weight when selecting a mounting position. Clean the tank, filter, hose and gun after use in accordance with the liquid and sprayer instructions.

The pump uses a 12V DC supply and draws up to 5A. The supplied battery cable is 2.5m long.

One-year warranty, subject to its terms.

✓ Application
Agricultural spot spraying, weed and pest control, fertiliser application, landscaping and property maintenance.

✓ Warranty
One-year warranty, subject to its terms.

✓ Model Specifications
SFSP-050-013-01A — 50L
Tank capacity: 50L.
Tank dimensions: 734mm long x 340mm wide x 424.5mm high.

SFSP-100-013-01A — 100L
Tank capacity: 100L.
Tank dimensions: 910mm long x 410mm wide x 475mm high.

✓ Supplied Equipment
12V Seaflo 22 Series diaphragm pump.
6m spray hose: 10mm internal diameter; 20bar (2000kPa) hose rating.
Hand spray gun with stainless steel lance and adjustable nozzle.
Lance storage clips and water inlet filter.
2.5m battery cable with DC quick-plug and battery clips.

✓ Performance & Control
Maximum pump flow: 5LPM.
Pump pressure limit: 100psi (about 690kPa).
Maximum flow and maximum pressure occur at different operating points.
Spray delivery depends on the nozzle setting and operating pressure.

✓ Liquid Compatibility
Agricultural spraying with liquids compatible with the tank, pump, seals, hose and gun.
Follow the chemical label for mixing, application and cleaning.

✓ Installation & Care
Secure to a suitable ATV, utility vehicle or trailer support.
Allow for the filled tank weight when assessing mounting capacity.
Keep the inlet filter clean and rinse the spraying system after use.

✓ Construction
HDPE tank with filling lid and carry handles.
Stainless steel lance with adjustable nozzle.
Filtration helps protect the pump from sediment.

✓ Electrical Supply
12V DC.
Maximum pump current: 5A.
Battery cable: 2.5m with DC quick-plug and battery clips.
Seaflo AG Knapsack Sprayer Electric 16L 12V
Seaflo AG Knapsack Sprayer Electric 16L 12V
Seaflo AG Knapsack Sprayer Electric 16L 12V PUMP-SFAESR-16A-01
$253.78 /each

The Seaflo 16L electric backpack sprayer provides portable spraying for weed and pest control, fertiliser application and garden or property maintenance. Its rechargeable 12V battery powers the diaphragm pump, so no manual pumping is required. A battery, charger and charging stand are included.

The supplied spray gun, lance and nozzle options let the spray pattern suit the task. The 1.2m hose connects the tank to the hand-held gun, while padded shoulder straps support the backpack during use. Filtration helps keep debris out of the pump and nozzle.

Maximum pump flow is 2.6LPM, with a pressure limit of 70psi (about 480kPa). These are separate limits; flow decreases as pressure rises, and delivery through the nozzle depends on the nozzle fitted and its setting.

The sprayer includes a 12V rechargeable battery and a 14V, 1A charger. Use the supplied charging equipment for the battery fitted to the sprayer.

Use intermittently, allowing cooling breaks between runs. Battery endurance depends on the nozzle, pressure, use pattern and battery condition.

Use liquids compatible with the complete sprayer and follow the chemical label for mixing and application. Clean the tank, filter, hose and gun after use in accordance with the liquid and sprayer instructions.

One-year warranty, subject to its terms.

✓ Application
Portable agricultural spot spraying, weed and pest control, fertiliser application, landscaping and property maintenance.

✓ Warranty
One-year warranty, subject to its terms.

✓ Model Specifications
Model: SFAESR-16A-01.
Tank capacity: 16L.
Maximum pump flow: 2.6LPM.
Pump pressure limit: 70psi (about 480kPa).
Maximum flow and maximum pressure occur at different operating points.
Sprayer hose length: 1.2m.

✓ Supplied Equipment
Rechargeable 12V battery.
14V, 1A battery charger and charging stand.
Spray hose, hand spray gun, lance and nozzle options.
Padded backpack straps.

✓ Duty
Intermittent use; allow cooling breaks between runs.
Battery endurance varies with nozzle, operating pressure, use pattern and battery condition.

✓ Liquid Compatibility
Use liquids compatible with the complete sprayer.
Follow the chemical label for mixing, application and cleaning.

✓ Operation & Care
Electric pump provides spraying without manual pumping.
Keep the filtration system clean.
Rinse the spraying system after use.

✓ Construction
Backpack tank with padded shoulder straps.
Hand spray gun with handle switch and lance.
Filtration system helps protect the pump and nozzle.

✓ Electrical Supply
Pump and battery voltage: 12V DC.
Supplied charger output: 14V, 1A.

✓ Dimensions
Tank dimensions: 220mm long x 330mm wide x 550mm high.
Seaflo Piston Hand Pump 477mm L
Seaflo Piston Hand Pump 477mm L
Seaflo Piston Hand Pump 477mm L PUMP-SFPH-H950-01
$39.86 /each

The Seaflo piston hand pump removes water from small bilge areas, kayaks, canoes and other accessible spaces without electricity. Its plunger handle provides manual pumping, and the supplied flexible hose carries the discharge away from the pump.

The compact pump can be carried between jobs or kept as a backup for marine, camping and general water-transfer tasks. Lower the pump intake into the water and operate the plunger handle to discharge through the hose.

A 0.5m flexible outlet hose is included, with a nominal diameter of 25mm (1"). The 1" hose connection is on the discharge side; water enters at the pump base.

The pump is 477mm long and has a maximum suction lift of 1m. Delivery depends on the pumping rate, lift and hose arrangement.

Suitable uses include fresh and saltwater transfer, small bilge areas and aquarium water changes. The lightweight construction and removable discharge hose help with storage and transport.

One-year warranty, subject to its terms.

✓ Application
Manual water removal and transfer for small bilge areas, kayaks, canoes, aquariums, camping and general utility tasks.
For fresh and saltwater.

✓ Warranty
One-year warranty, subject to its terms.

✓ Model Specifications
Model: SFPH-H950-01.
Pump type: manual piston hand pump.
Pump length: 477mm.
Maximum suction lift: 1m.
Inlet: water intake at the pump base.
Outlet hose diameter: 25mm (1").
Supplied outlet hose length: 0.5m.

✓ Supplied Equipment
Hand pump with removable 0.5m flexible discharge hose.

✓ Operation
Manual plunger handle; no electricity required.
Place the intake in the water and pump using the handle.
Actual delivery depends on pumping rate, lift and the hose arrangement.

✓ Construction
Lightweight portable pump with plunger handle.
Removable flexible discharge hose for storage.
Seaflo 800GPH 04 Series straight-intake livewell pump
Seaflo 800GPH 04 Series straight-intake livewell pump
Seaflo Live Well Pump 800GPH 12V PUMP-SFBP1-G800-04
$54.08 /each

The Seaflo 800GPH 04 Series livewell pump supplies water to bait tanks and fish-holding livewells from a flooded inlet. Its removable motor cartridge gives access to the motor and impeller for cleaning or replacement without disconnecting the fixed plumbing.

Maximum flow is 61LPM and maximum head is 4m. These are separate limits: flow decreases as the delivery height and hose resistance increase. Actual flow through the livewell depends on the hose and spray-bar arrangement.

The straight threaded intake mounts through the hull or transom below the waterline. The discharge connects to 19mm (3/4") hose. Sealing nut and washers are included for the through-hull mounting.

The pump uses a 12V DC supply and has 1m leads. It requires water at the inlet and does not lift water into a dry suction line.

Use intermittently, allowing cooling breaks between runs. The pump supplies water to a livewell or bait tank; it does not provide a guaranteed oxygen level or fish-holding time.

The cartridge release allows access to the motor and impeller for maintenance. Keep the intake and impeller clear of debris. Maximum liquid temperature is 43°C. Do not rely on dry-running capability as an automatic shutdown when the water supply is lost.

Two-year warranty, subject to its terms.

Seaflo Livewell Pump Installation Instructions

✓ Application
Water supply to marine livewells, bait tanks and fish-holding tanks.

✓ Warranty
Two-year warranty, subject to its terms.

✓ Model Specifications
Model: SFBP1-G800-04.
Series: 04; straight intake.
Nominal model size: 800GPH.
Maximum flow: 61LPM.
Maximum head: 4m.
Inlet: straight threaded through-hull intake.
Outlet hose connection: 19mm (3/4").

✓ Supplied Equipment & Service Access
Through-hull mounting nut and washers.
Removable motor cartridge gives access to the motor and impeller without disconnecting fixed plumbing.

✓ Performance
Maximum flow and maximum head occur separately.
Available flow decreases as delivery height and hose resistance increase.

✓ Water Supply
Flooded inlet required; not self-priming.
Install the intake below the waterline as described in the instructions.
Maximum liquid temperature: 43°C.

✓ Duty
Intermittent: the motor needs cooling breaks between runs. It is not designed to keep pumping without stopping.

✓ Installation & Maintenance
Straight intake for through-hull or transom installation.
Keep the intake and impeller clear of debris.
Dry-running capability does not provide automatic shutdown when the water supply is lost.

✓ Construction
Cartridge-style motor and impeller assembly.
Water-cooled motor housing.

✓ Electrical Supply
12V DC.
Lead length: 1m.
Seaflo Macerator 12GPM 12V
Seaflo Macerator 12GPM 12V
Seaflo Macerator 12GPM 12V PUMP-SFMP1-120-01
$250.14 /each

The Seaflo 12V macerator pump empties marine and RV holding tanks and transfers waste from fish boxes or livewell receptacles. Its four-blade stainless steel cutter breaks down normal waste before it passes through the pump and discharge hose.

Maximum open flow is 45LPM. Delivery decreases as discharge pressure and hose resistance increase, and also depends on the waste being pumped.

Inlet: 1 1/2" male NPT thread, with a 38mm (1 1/2") hose barb.
Outlet: 25mm (1") hose barb.

The sealed motor has sealed bearings, O-ring seals and a corrosion-resistant coating. Motor thermal protection helps protect against overheating. The pump is ignition protected.

The flexible-impeller pump is self-priming. The installation sheet gives a suction lift of up to 1.5m with a wet impeller or 1.2m with a dry impeller. Mount close to the holding tank to reduce suction losses and time spent without liquid.

Use intermittently and allow cooling breaks between runs. Switch the pump off as soon as the tank empties; brief dry-running capability does not provide automatic empty-tank shutdown. Flush the tank and pump with water after use.

The pump handles normal holding-tank waste and fish-box residues such as scales. It is not suitable for hard objects, rags, cloth wipes or sanitary products. Waste must be discharged to an appropriate collection or disposal point.

The pump requires a 12V DC supply and has a maximum current draw of 12A.

Two-year warranty, subject to its terms.

Seaflo Macerator Pump Specifications & Installation Notes

✓ Application
Emptying marine and RV holding tanks, fish boxes and livewell receptacles.
For normal waste that can pass through the macerator; not hard objects, rags, wipes or sanitary products.

✓ Warranty
Two-year warranty, subject to its terms.

✓ Model Specifications
Model: SFMP1-120-01.
Maximum open flow: 45LPM.
Inlet: 1 1/2" male NPT thread and 38mm (1 1/2") hose barb.
Outlet: 25mm (1") hose barb.
Self-priming suction lift: up to 1.5m with wet impeller; up to 1.2m with dry impeller.

✓ Supplied Operation
Motor-driven flexible-impeller pump with a four-blade stainless steel macerator cutter.
Not an automatic empty-tank shutoff pump.

✓ Performance
Open flow is the zero-discharge-pressure figure.
Delivery depends on fluid viscosity, suction conditions and discharge resistance.

✓ Duty
Intermittent: the motor needs cooling breaks between runs. It is not designed to keep pumping without stopping.
Switch off when the tank is empty; brief dry-running capability is not permission for prolonged dry operation.

✓ Installation & Care
Mount as close to the holding tank as possible.
Flush the tank and pump with water after use.
Use an appropriate waste collection or disposal point.

✓ Construction & Protection
Four-blade stainless steel cutter.
Flexible rubber impeller.
Sealed motor with O-ring seals, sealed bearings and corrosion-resistant coating.
Motor thermal protection.
Ignition protected.

✓ Electrical Supply
12V DC.
Maximum current draw: 12A.
SEAFLO SFGP2-032-003-01 transfer gear pump
SEAFLO SFGP2-032-003-01 transfer gear pump
Seaflo Diesel Transfer Pump 12V 3.2GPM PUMP-SFGP1-032-003-01
$276.59 /each
SEAFLO SFGP2-032-003-01 transfer gear pump
Seaflo Diesel Transfer Pump 24V 3.2GPM PUMP-SFGP2-032-003-01
$276.59 /each

Seaflo gear transfer pumps move diesel, engine oil, transmission fluid, lubricants and other compatible viscous liquids for workshop, machinery, agricultural and marine servicing. The positive-displacement gear design can pump in either direction.

SFGP1-032-003-01: 12V DC; maximum current 10A.
SFGP2-032-003-01: 24V DC; maximum current 6A.

Maximum open flow is 12LPM. Actual delivery depends on the liquid viscosity and temperature, suction conditions and discharge resistance.

Inlet: 3/8" female NPT thread.
Outlet: 3/8" female NPT thread.

Two 3/8" male NPT × 1/2" hose-barb fittings are supplied for nominal 12.5mm (1/2") hose. The motor has wire leads.

The pump suits oil changes and fluid transfer in vehicles, machinery, workshops and marine equipment. Use compatible hydraulic oils and other lubricants within the pump’s liquid-temperature limit of 60°C. Do not use for petrol, gasoline or other volatile fuels.

The self-priming design and reversible pumping direction provide flexibility for transfer tasks. Liquid viscosity and the inlet arrangement affect priming and delivery.

Use intermittently, allowing the motor to cool between runs. Follow the operating limits in the instructions supplied with the pump.

The pump has a metal head and gears, a stainless steel shaft and a thermally protected motor. Thermal protection helps protect against overheating during operation.

Two-year warranty, subject to its terms.

Seaflo Gear Pump Specifications

✓ Application
Diesel, engine oil, transmission fluid, compatible hydraulic oils, lubricants and other compatible viscous-liquid transfer.
Workshop, machinery, agricultural, industrial and marine servicing.

✓ Warranty
Two-year warranty, subject to its terms.

✓ Model Specifications
SFGP1-032-003-01
Supply: 12V DC.
Maximum open flow: 12LPM.
Inlet: 3/8" female NPT thread.
Outlet: 3/8" female NPT thread.
Maximum current draw: 10A.

SFGP2-032-003-01
Supply: 24V DC.
Maximum open flow: 12LPM.
Inlet: 3/8" female NPT thread.
Outlet: 3/8" female NPT thread.
Maximum current draw: 6A.

✓ Supplied Equipment
Gear pump with wire leads.
Two 3/8" male NPT × 1/2" hose-barb fittings for nominal 12.5mm (1/2") hose.

✓ Performance & Operation
Positive-displacement gear pump; capable of pumping in either direction.
Self-priming.
12LPM is the maximum open-flow figure; delivery depends on viscosity, temperature and inlet and outlet resistance.

✓ Duty
Intermittent: allow the motor to cool between runs.
Follow the operating limits in the instructions supplied with the pump.

✓ Liquid Compatibility
Diesel, engine oil, transmission fluid and compatible lubricants or viscous liquids.
Maximum liquid temperature: 60°C.
Not for petrol, gasoline or other volatile fuels.

✓ Construction
Metal pump head and gears.
Stainless steel shaft.
Thermally protected motor.

✓ Electrical Supply
12V DC model: maximum current draw 10A.
24V DC model: maximum current draw 6A.
Select the model to match the available DC supply.
Wire leads.

The Davey StarFlo DSF300 is a single-speed pool circulation pump for filtration, sanitising systems and solar heating. Its multi-fit design and 40mm and 50mm barrel unions suit replacement installations, in-ground and above-ground pools, large swim spas and plunge pools.

The motor has an electrical input of 1.1kW and a shaft output of 0.75kW. Available flow depends on the system head, pipework, filter condition and connected equipment; use the DSF300 performance curve to select the operating point.

Inlet: 40mm and 50mm PVC barrel-union connections.
Outlet: 40mm and 50mm PVC barrel-union connections.

The included barrel unions and multi-fit design help with replacement installations. Check the dimension drawing and existing pipework before choosing a replacement. A 3m power lead with an Australian 10amp three-pin plug is included.

The corrosion-resistant, UV-resistant construction includes a Noryl impeller, 316 stainless steel motor shaft and silicon carbide/Viton mechanical seal. The totally enclosed motor has self-resetting thermal overload protection. The water circuit is double insulated and has an equipotential bonding point.

A removable clear strainer lid provides basket access, and drain plugs allow water to be drained for maintenance. The pump is serviceable.

The pump uses a 220–240V single-phase, 50Hz supply. Maximum water temperature is 40°C and maximum ambient temperature is 50°C. Sound level is 62dBA at 1m.

Three-year Davey warranty, subject to its terms.

Davey StarFlo DSF300 Specifications
Davey StarFlo Installation & Operating Instructions

✓ Application
Residential pool filtration and circulation for sanitising systems.
In-ground and above-ground pools, large swim spas, plunge pools and solar pool heating.

✓ Warranty
Three-year Davey warranty, subject to its terms.

✓ Model Specifications
Model: DSF300.
Pump type: single-speed pool circulation pump.
Motor input P1: 1.1kW.
Motor output P2: 0.75kW.
Inlet: 40mm and 50mm PVC barrel-union connections.
Outlet: 40mm and 50mm PVC barrel-union connections.

✓ Included Equipment
40mm and 50mm barrel unions.
3m power lead with Australian 10amp three-pin plug.

✓ Performance
Use the model-specific hydraulic curve for the required flow at the system head.
Available flow depends on pipework, filter condition and connected equipment.

✓ Operation & Protection
Universal multi-fit design for retrofit and service applications.
Check pipe centres, union connections and available space against the dimension drawing.
Self-resetting thermal overload protection.

✓ Water Supply & Operating Limits
Maximum water temperature: 40°C.
Maximum ambient temperature: 50°C.
Sound level: 62dBA at 1m.

✓ Construction
Corrosion-resistant and UV-resistant construction.
Heavy-duty totally enclosed motor.
Noryl impeller.
316 stainless steel motor shaft.
Silicon carbide/Viton mechanical seal.
Double-insulated water circuit with equipotential bonding point.

✓ Maintenance & Installation
Removable transparent strainer lid for basket access.
Drain plugs for draining and servicing.
Serviceable pump construction.

✓ Electrical Supply
220–240V single phase, 50Hz.
Run current: 5.8A.
Nominal speed: 2900rpm.
Motor enclosure: IP55. Insulation: Class F.

✓ Physical Details
Net weight: 10kg.
Use the dimension drawing to check installation fit.

The Davey SureFlo DSF900 is a single-speed circulation pump for residential pool filtration, sanitising systems and solar heating. Its multi-fit design suits in-ground and above-ground pools, large swim spas and plunge pools, with self-aligning unions for installation.

The motor has an electrical input of 0.9kW and a shaft output of 0.65kW. Choose the pump from its flow-at-head curve, allowing for the filter, pipework, heating and other connected equipment.

Inlet: accepts 40mm PVC pipe internally or a 50mm PVC socket/bell end externally.
Outlet: accepts 40mm PVC pipe internally or a 50mm PVC socket/bell end externally.

Self-aligning barrel unions assist with installation. The multi-fit design supports replacement applications, but pipe centres and clearances should be checked against the dimension drawing. A 3m power lead with an Australian 10amp three-pin plug is included.

The pump uses corrosion-resistant and UV-resistant materials, a Noryl impeller, 316 stainless steel shaft and silicon carbide/Viton mechanical seal. The totally enclosed motor has self-resetting thermal overload protection. The water circuit is double insulated and has an equipotential bonding point.

The clear strainer lid gives access for basket maintenance, and drain plugs simplify draining and servicing. Davey publishes a 54–56dBA sound range for this family.

The pump uses a 220–240V single-phase, 50Hz supply. Maximum water temperature and ambient temperature are both 40°C.

Three-year Davey warranty, subject to its terms.

Davey SureFlo DSF900 Specifications
Davey StarFlo SF / DSF900 Installation & Operating Instructions

✓ Application
Residential pool filtration and circulation for sanitising systems.
In-ground and above-ground pools, large swim spas, plunge pools and solar pool heating.

✓ Warranty
Three-year Davey warranty, subject to its terms.

✓ Model Specifications
Model: DSF900.
Pump type: single-speed pool circulation pump.
Motor input P1: 0.9kW.
Motor output P2: 0.65kW.
Inlet: accepts 40mm PVC pipe internally or a 50mm PVC socket/bell end externally.
Outlet: accepts 40mm PVC pipe internally or a 50mm PVC socket/bell end externally.

✓ Included Equipment
Self-aligning barrel unions.
3m power lead with Australian 10amp three-pin plug.

✓ Performance
Use the model-specific hydraulic curve for the required flow at the system head.
Available flow depends on pipework, filter condition and connected equipment.

✓ Operation & Protection
Universal multi-fit design.
Check pipe centres, union connections and space against the dimension drawing before replacing another pump.
Self-resetting thermal overload protection.

✓ Water Supply & Operating Limits
Maximum water temperature: 40°C.
Maximum ambient temperature: 40°C.
Published range sound level: 54–56dBA.

✓ Construction
Corrosion-resistant and UV-resistant construction.
Heavy-duty totally enclosed motor.
Noryl impeller.
316 stainless steel motor shaft.
Silicon carbide/Viton mechanical seal.
Double-insulated water circuit with equipotential bonding point.

✓ Maintenance & Installation
Removable transparent strainer lid.
Drain plugs for draining and servicing.
Serviceable pump construction.

✓ Electrical Supply
220–240V single phase, 50Hz.
Run current: 4.6A.
Nominal speed: 2900rpm.
Motor enclosure: IP55. Insulation: Class F.

✓ Physical Details
Net weight: 10.5kg.
Use the dimension drawing to check installation fit.

The Davey Silensor SLS200 is a single-speed, water-cooled pump for pool filtration, automatic pool cleaning, backwashing, water features and spa jets. It also suits solar, gas and heat-pump pool heating, with a quiet motor design and built-in dry-run and mechanical-seal protection.

The motor has an electrical input of 1.09kW and a shaft output of 0.775kW. Use the SLS200 hydraulic curve to check the flow available against the resistance of the pool pipework, filter, cleaner and heating equipment.

Inlet: 40mm PVC connection.
Outlet: 40mm PVC connection.

Quick-coupling barrel unions assist with installation and removal. The SLS layout suits retrofit applications; check the dimension drawing and pipework before choosing a replacement. A 3m power lead is included.

The water-cooled motor reduces transmitted noise and vibration, with a published sound level of 54–56dBA. It does not require air ventilation for motor cooling, giving more flexibility in positioning.

Built-in dry-run protection helps minimise pump damage if water is lost, and mechanical-seal protection supports service life. These protections do not remove the need to maintain the pump and water supply.

Corrosion-resistant and UV-resistant polypropylene components, a 316 stainless steel shaft and an epoxy-protected motor shell suit outdoor poolside conditions. The water circuit is double insulated and has an equipotential bonding point. ABS barrel unions and a drain plug assist with servicing.

The pump uses a 220–240V, 50Hz supply and has an IP56 motor enclosure. Maximum water temperature and ambient temperature are both 40°C.

Three-year Davey warranty, subject to its terms.

Davey Silensor SLS200 Specifications
Davey Silensor Installation & Operating Instructions

✓ Application
Pool filtration, automatic pool cleaning and backwashing.
Water features, spa jets, and solar, gas and heat-pump pool heating.

✓ Warranty
Three-year Davey warranty, subject to its terms.

✓ Model Specifications
Model: SLS200.
Pump type: single-speed, water-cooled pool circulation pump.
Motor input P1: 1.09kW.
Motor output P2: 0.775kW.
Inlet: 40mm PVC connection.
Outlet: 40mm PVC connection.

✓ Included Equipment
Quick-coupling barrel unions.
3m power lead.

✓ Performance
Use the model-specific hydraulic curve for the required flow at the system head.
Available flow depends on pipework, filter condition and connected equipment.

✓ Operation & Protection
Water-cooled motor captures noise and vibration.
Motor does not require air ventilation for cooling.
Dry-run protection helps minimise damage if water is lost.
Mechanical-seal protection.
SLS layout is designed for retrofit applications; check the dimension drawing for fit.

✓ Water Supply & Operating Limits
Maximum water temperature: 40°C.
Maximum ambient temperature: 40°C.
Published sound level: 54–56dBA.

✓ Construction
Corrosion-resistant and UV-resistant polypropylene components.
Rust-resistant casing and 316 stainless steel shaft.
Heavy-duty motor impeller.
Motor shell protected with Armourspray VC epoxy coating.
ABS quick-coupling barrel unions.
Double-insulated water circuit with equipotential bonding point.

✓ Maintenance & Installation
Drain plug for draining, removal and servicing.
Keep the strainer basket and water path clear.

✓ Electrical Supply
220–240V, 50Hz.
Nominal speed: 2850rpm.
Motor enclosure: IP56. Insulation: Class F.

✓ Physical Details
Net weight: 11.5kg.
Use the SLS dimension drawing to check replacement fit.

The Davey ProMaster PM400BT is a variable-speed, water-cooled pool pump with Bluetooth smartphone control and a selectable speed dial. It suits filtration, in-floor cleaning and pool heating systems, with a large 4.5L leaf basket and connections for external pool controls.

The speed can be adjusted from 1050 to 3100rpm using the dial or Bluetooth control. Lower speeds reduce energy use where they still provide the flow required by the filter, cleaner, chlorinator and heating equipment. The PM400BT application guide lists pools up to 140,000 litres; select the speed and operating time for the actual system.

Inlet: 50mm PVC connection.
Outlet: 50mm PVC connection.

The integrated variable-speed drive and Bluetooth connection support control and speed schedules through the Davey Pool Pump app for iOS and Android. A 3m power lead is included.

Programmable boost cycling improves surface skimming and supports in-floor cleaning. Flow/speed compensation helps respond as filter resistance increases. The weatherproof RJ45 port provides a connection for speed adjustment from compatible external pool controllers, gas heaters or heat pumps.

The backwash mode alternates selected low and high speeds to agitate filter media, with a two-minute automatic shutoff to limit accidental draining. Loss-of-prime protection helps protect the pump when water is lost, and a multicoloured LED indicates operating conditions and warnings.

The water-cooled motor is rated down to 50dBA, depending on operating speed. The 4.5L leaf basket provides capacity between cleanings, and a drain plug assists with draining and maintenance. The water circuit is double insulated and has an equipotential bonding point.

The pump uses a 220–240V, 50/60Hz supply. Electrical input varies with speed: 126W at dial 1, 728W at dial 5 and 1639W at dial 10. Maximum water temperature is 40°C and maximum ambient temperature is 50°C.

Three-year Davey warranty, subject to its terms.

Davey ProMaster PM400BT Specifications
Davey ProMaster PM400BT Installation & Operating Instructions

✓ Application
Residential pool filtration and circulation, in-floor cleaning and compatible external pool control.
Solar, gas and heat-pump pool heating.
Published PM400BT application guide: pools up to 140,000 litres; confirm required flow and system head.

✓ Warranty
Three-year Davey warranty, subject to its terms.

✓ Model Specifications
Model: PM400BT, Premium VSD400.
Pump type: variable-speed, water-cooled pool pump.
Motor speed: 1050–3100rpm.
Inlet: 50mm PVC connection.
Outlet: 50mm PVC connection.
Leaf basket capacity: 4.5L.
Maximum electrical input: 1.639kW at dial position 10.

✓ Included Equipment
Pump with integrated variable-speed drive, selectable speed dial and Bluetooth control.
3m power lead.

✓ Performance
Use the model-specific hydraulic curve for the required flow at the system head.
Available flow depends on pipework, filter condition and connected equipment.

✓ Operation & Protection
Bluetooth control and speed schedules through the Davey Pool Pump app for iOS and Android.
Programmable boost cycling for skimming and in-floor cleaning.
Flow/speed compensation helps respond to increasing filter resistance.
Weatherproof RJ45 port for speed control from compatible external pool controllers or heaters.
Backwash mode alternates selected low and high speeds, with a two-minute automatic shutoff.
Loss-of-prime protection.
Multicoloured LED indicates operating conditions and warnings.

✓ Water Supply & Operating Limits
Maximum water temperature: 40°C.
Maximum ambient temperature: 50°C.
Noise rated down to 50dBA; actual sound depends on operating speed and installation.

✓ Construction
Water-cooled motor and integrated variable-frequency drive.
Large 4.5L leaf basket/lint pot.
Double-insulated water circuit with equipotential bonding point.
Drain plug for draining and servicing.

✓ Maintenance & Installation
Clean the leaf basket and maintain the filter to preserve flow.
Use the dimension drawing to check installation and maintenance access.

✓ Electrical Supply
220–240V, 50/60Hz.
Electrical input: 126W at dial 1; 728W at dial 5; 1639W at dial 10.
Backwash input varies with selected speeds.
Motor enclosure: IP45. Insulation: Class F.

✓ Physical Details
Net weight: 14.5kg.
Use the dimension drawing to check installation fit.

The Davey EcoPure DEP2540 is a 25" fibreglass media filter for swimming pools, swim spas and plunge pools. Its top-mounted six-way valve connects to 40mm PVC pressure pipe through the included barrel unions.

Water passes through the media bed to remove suspended dirt before returning to the pool. The filter suits fresh, salt and mineral-salt pool water, using glass, sand or Zelbrite media.

Inlet from pump: 40mm socket for PVC pressure pipe.
Outlet to pool: 40mm socket for PVC pressure pipe.
Waste/backwash: 40mm socket for PVC pressure pipe.

The filter includes the fibreglass tank, internal laterals, six-way valve, pressure gauge, backwash sight glass and barrel unions.

Glass media for the DEP2540:
Fine/medium glass: 5 × 15kg bags (75kg)
Medium/coarse glass: 3 × 15kg bags (45kg)

These glass quantities total 120kg. Sand and Zelbrite use different loading quantities; follow the instructions for the chosen media.

Match the pump to both duties: filtration flow must stay within 260LPM, and the pump must deliver at least 173LPM through the backwash circuit to clean the media. Allow for resistance in the pipework and waste line.

The valve provides Filter, Backwash, Rinse, Waste, Recirculate and Closed positions. The pressure gauge helps identify when cleaning is needed, and the sight glass shows the water leaving during backwashing. Stop the pump before changing valve position.

The tank is made from UV-stabilised, filament-wound fibreglass. ABS barrel unions allow pipe connections to be disconnected for servicing, while the internal lateral underdrain collects filtered water and distributes backwash flow.

Install on a firm, level base and allow at least 400mm above the valve for removal and servicing. Check the dimension drawing when replacing an existing filter. Maximum water temperature is 40°C.

Follow the installation guide for media loading, initial backwash and rinsing. Relieve pressure before servicing and never run the pump with the valve closed.

Davey warranty: 10 years on the tank, three years on the multiport valve and one year on other components, subject to its terms.

Davey EcoPure Media Filter Specifications
Davey EcoPure Installation & Operating Instructions
Davey CrystalClear Glass Media Specifications & Usage Chart

✓ Application
Pool filtration for in-ground and above-ground pools, swim spas and plunge pools.
Fresh, salt and mineral-salt pool water.

✓ Warranty
Davey warranty: 10 years on the tank, three years on the multiport valve and one year on other components, subject to its terms.

✓ Model Specifications
Model: DEP2540.
Nominal tank size: 25".
Inlet from pump: 40mm socket for PVC pressure pipe.
Outlet to pool: 40mm socket for PVC pressure pipe.
Waste/backwash: 40mm socket for PVC pressure pipe.
Maximum filtration flow: 260LPM.
Minimum backwash flow: 173LPM.
Filtration area: 0.32m².

✓ Included Equipment
Fibreglass tank with internal laterals and underdrain.
Top-mounted six-way multiport valve.
Pressure gauge, backwash sight glass and ABS barrel unions.

✓ Glass Media Requirements
Fine/medium glass: 5 × 15kg bags (75kg).
Medium/coarse glass: 3 × 15kg bags (45kg).
Total glass charge: 120kg in eight 15kg bags.
Sand and Zelbrite are alternatives with different loading quantities.

✓ Pump Selection
Keep filtration flow at or below 260LPM.
Pump must deliver at least 173LPM through the installed backwash circuit.
Allow for pipework, filter and waste-line resistance.
Six-hour turnover at 260LPM: 93,600 litres.

✓ Construction
UV-stabilised, filament-wound fibreglass tank.
ABS barrel unions.
Large lateral underdrain for filtration and backwashing.

✓ Installation & Clearance
Firm, level base with access for servicing.
Minimum clearance above valve: 400mm.
Nominal tank diameter: 635mm.
Check the dimension drawing before replacing an existing filter.

✓ Water Supply
Maximum water temperature: 40°C.
Suitable for properly maintained fresh, salt and mineral-salt pool water.

✓ Valve & Maintenance
Positions: Filter, Backwash, Rinse, Waste, Recirculate and Closed.
Stop the pump before changing valve position.
Do not run the pump with the valve closed.
Use the pressure gauge and sight glass to assess backwashing.
Relieve system pressure before servicing.
Davey Supercell 24018P pressure tank

Davey Supercell P steel pressure tanks hold a reserve of water under pressure for household, farm and other water-pressure systems. A flexible rubber diaphragm separates the water from compressed air, which pushes water out when a tap opens. This reserve allows smaller amounts of water to be used without starting the pump each time. Fewer starts reduce wear from repeated starting and stopping, helping extend pump life, and can reduce electricity use and running costs. Pipe-mounted tanks connect vertically to the pump delivery pipework and need suitable support. Free-standing tanks sit upright on their own base, with an inlet elbow for horizontal pipework.

24008P: 8L; pipe mounted; 1" BSP male thread.
24018P: 18L; pipe mounted; 1" BSP male thread.
24040P: 40L; pipe mounted; 1" BSP male thread.
24060P: 60L; free standing; 1" BSP female thread.
24100P: 100L; free standing; 1" BSP female thread.

Nominal tank volume is the vessel size, not the amount of water available between pump starts. Usable draw-off depends on the pump’s start and stop pressures and the tank air charge. At pump start/stop pressures of 200–400kPa, usable water draw-off is roughly 40% of nominal tank volume. Other pressure settings and control types give different results.

The steel shell has an epoxy primer and two-part polyurethane enamel finish for corrosion and UV resistance. Inside, a butyl-rubber diaphragm and virgin polypropylene liner keep the water separated from the air cushion and steel shell. The water connection is stainless steel.

The diaphragm and liner are suitable for potable-water applications. Other uses include rainwater and booster systems, irrigation, water-hammer control and suitably designed hydronic expansion or mains-water toilet-flushing systems. Select the tank and controls for the application.

Maximum working pressure is 1000kPa and maximum water temperature is 90°C. Protect the tank and connected pipework from freezing.

Set the air charge to suit the pump controls and system pressures. Pressure-switch, electronic and variable-speed systems can require different settings; follow the tank and pump/controller instructions.

Install vertically in a covered, dry position with drainage and access for servicing. Pipe-mounted models need suitable support; free-standing models need a firm base. The 60L and 100L tanks have stainless steel inlet elbows for horizontal pipework. Release the water pressure before checking or adjusting the air charge.

Five-year Davey warranty, subject to its terms.

Davey Supercell P Specifications & Draw-off Table
Davey Supercell Pressure Tank Installation & Operating Instructions

✓ Application
Water storage under pressure for household, farm, irrigation and industrial pressure systems.
Also suitable for appropriately designed water-hammer control, hydronic expansion and mains-water toilet-flushing systems.
Potable-water-grade diaphragm and liner.

✓ Warranty
Five-year Davey warranty, subject to its terms.

✓ Model Specifications
24008P
Nominal tank volume: 8L.
Maximum working pressure: 1000kPa.
Water connection: 1" BSP male thread.
Mounting: pipe mounted.

24018P
Nominal tank volume: 18L.
Maximum working pressure: 1000kPa.
Water connection: 1" BSP male thread.
Mounting: pipe mounted.

24040P
Nominal tank volume: 40L.
Maximum working pressure: 1000kPa.
Water connection: 1" BSP male thread.
Mounting: pipe mounted.

24060P
Nominal tank volume: 60L.
Maximum working pressure: 1000kPa.
Water connection: 1" BSP female thread.
Mounting: free standing.

24100P
Nominal tank volume: 100L.
Maximum working pressure: 1000kPa.
Water connection: 1" BSP female thread.
Mounting: free standing.

✓ Draw-off & Sizing
Nominal vessel volume is not the usable water draw-off.
Draw-off depends on pump start/stop pressures and tank air charge.
Published comparison at a 200–400kPa pressure-switch range:
24008P: 3.2L nominal draw-off.
24018P: 7.2L nominal draw-off.
24040P: 15.2L nominal draw-off.
24060P: 22.8L nominal draw-off.
24100P: 40.0L nominal draw-off.
This comparison is not a universal pressure-setting recommendation.

✓ Construction
Deep-drawn steel shell.
Butyl-rubber diaphragm is held in place inside the tank (captive design), separating air and water.
Virgin polypropylene liner separates water from the steel shell.
Stainless steel water connection.
Epoxy primer with a two-part polyurethane enamel finish.
Captive diaphragm is non-serviceable; diaphragm failure requires tank replacement.

✓ Installation & Mounting
Install vertically in a covered, dry position.
Provide drainage and access for servicing.
Pipe-mounted models: suitable tank and pipework support required.
60L/100L models: free-standing base and stainless steel inlet elbow for horizontal pipework.

✓ Operating Limits
Maximum working pressure: 1000kPa.
Maximum water temperature: 90°C.
Protect tank and pipework from freezing.

✓ Air Charge & Controls
Set air charge to suit the pump/controller and system pressures.
Factory pre-charge is not a universal installation setting.
Follow the tank and pump/controller instructions for the applicable control type.
Release water pressure before checking or adjusting air charge.

✓ Dimensions & Weight
24008P: 203mm diameter × 317mm high; shipping weight 2.6kg.
24018P: 279mm diameter × 368mm high; shipping weight 4.3kg.
24040P: 388mm diameter × 419mm high; shipping weight 9.0kg.
24060P: 388mm diameter × 626mm high; shipping weight 12.5kg.
24100P: 430mm diameter × 804mm high; shipping weight 19.1kg.
DAVEY Pressure Tank SupercellF 60litre 860 kPa - Free Standing (24060F)

Davey Supercell F composite pressure tanks hold a reserve of water under pressure for household, farm and industrial water systems. A flexible rubber diaphragm separates the water from compressed air, which pushes water out when a tap opens. This reserve allows smaller amounts of water to be used without starting the pump each time. Fewer starts reduce wear from repeated starting and stopping, helping extend pump life, and can reduce electricity use and running costs. The fibreglass shell and non-metal water-contact components resist corrosion, making this range useful in coastal and humid locations. The free-standing tank sits upright on its own base.

24060F: 60L; 1" BSP male thread; free standing.
24080F: 80L; 1" BSP male thread; free standing.
24100F: 100L; 1" BSP male thread; free standing.
24130F: 130L; 1" BSP male thread; free standing.
24200F: 200L; 1 1/4" BSP male thread; free standing.
24250F: 250L; 1 1/4" BSP male thread; free standing.

Nominal tank capacity is the vessel size, not the amount of water available between pump starts. Usable draw-off depends on the start and stop pressures and the air charge. At pump start/stop pressures of 200–400 kPa, these tanks provide roughly 38% of their nominal volume between starts. Other pressure settings and control types give different results.

The tank has a continuous-strand fibreglass outer shell sealed with epoxy resin, a polypropylene inner shell and a virgin copolymer polypropylene liner. A butyl-rubber diaphragm separates the air and water, and the water connection is reinforced plastic. The non-metal water-contact components avoid corrosion of metal wetted parts. The diaphragm and liner are suitable for potable-water applications.

Maximum working pressure is 860 kPa. Water temperature must remain between 1°C and 50°C. Protect the tank and connected pipework from freezing.

Install upright on a firm base in a covered, dry position with drainage and access for servicing. The water connection is at the bottom of the tank and faces horizontally. Do not overtighten the plastic connection.

Set the air charge to suit the pump controls and system pressures. Pressure-switch, electronic and variable-speed systems can require different settings; follow the tank and pump/controller instructions. Release all water pressure before checking or adjusting the air charge.

Five-year Davey warranty, subject to its terms.

Davey Supercell F Specifications & Draw-off Table
Davey Supercell F Installation & Operating Instructions

✓ Application
Water storage under pressure for household, farm, irrigation and industrial water systems.
Also suitable for appropriately designed water-hammer control.
Potable-water-grade diaphragm and liner.

✓ Warranty
Five-year Davey warranty, subject to its terms.

✓ Model Specifications
24060F
Nominal tank capacity: 60L.
Water connection: 1" BSP male thread.
Mounting: vertical, free standing.

24080F
Nominal tank capacity: 80L.
Water connection: 1" BSP male thread.
Mounting: vertical, free standing.

24100F
Nominal tank capacity: 100L.
Water connection: 1" BSP male thread.
Mounting: vertical, free standing.

24130F
Nominal tank capacity: 130L.
Water connection: 1" BSP male thread.
Mounting: vertical, free standing.

24200F
Nominal tank capacity: 200L.
Water connection: 1 1/4" BSP male thread.
Mounting: vertical, free standing.

24250F
Nominal tank capacity: 250L.
Water connection: 1 1/4" BSP male thread.
Mounting: vertical, free standing.

✓ Draw-off & Sizing
Nominal capacity is not the usable water draw-off.
Comparison at 200–400 kPa pump start/stop pressures:
24060F: 22.8L nominal draw-off.
24080F: 30.4L nominal draw-off.
24100F: 37.3L nominal draw-off.
24130F: 49.4L nominal draw-off.
24200F: 76.0L nominal draw-off.
24250F: 95.0L nominal draw-off.
Other pressure settings and control types give different results.

✓ Construction
Continuous-strand fibreglass outer shell with epoxy seal.
Polypropylene inner shell and virgin copolymer polypropylene liner.
Butyl-rubber diaphragm held in place inside the tank.
Reinforced-plastic water connection; non-metal wetted components.

✓ Installation & Mounting
Vertical free-standing configuration; place on a firm base.
Bottom water connection facing horizontally.
Install in a covered, dry position with drainage and servicing access.
Do not overtighten the plastic water connection.

✓ Operating Limits
Maximum working pressure: 860 kPa.
Water temperature: 1°C to 50°C.
Protect tank and pipework from freezing.

✓ Air Charge & Controls
Air charge must suit the pump/controller and system pressures.
Follow the tank and pump/controller instructions for the applicable control type.
Release water pressure before checking or adjusting air charge.

✓ Dimensions & Weight
24060F: 418mm diameter × 649mm high; shipping weight 8.6kg.
24080F: 418mm diameter × 852mm high; shipping weight 10.9kg.
24100F: 418mm diameter × 967mm high; shipping weight 12.7kg.
24130F: 418mm diameter × 1227mm high; shipping weight 15.2kg.
24200F: 542mm diameter × 1098mm high; shipping weight 21.3kg.
24250F: 542mm diameter × 1303mm high; shipping weight 26.3kg.
Franklin pressure tank family showing representative sizes and mounting configurations; individual model appearance varies

This Franklin 35L pressure tank holds a reserve of water under pressure for domestic water supply, irrigation and pressure-boosting systems. A flexible rubber diaphragm separates the water from compressed air, which pushes water out when a tap opens. This reserve allows smaller amounts of water to be used without starting the pump each time. Fewer starts reduce wear from repeated starting and stopping, helping extend pump life, and can reduce electricity use and running costs. The tank stands upright on its own base.

Water connection: 1" BSP male thread.

Nominal tank capacity is the vessel size, not the amount of water available before the pump restarts. Usable draw-off depends on the pump’s start and stop pressures and the tank air charge. Size the tank for the usable draw-off and pump cycling requirements of the system.

The diaphragm separates the stored water from the air cushion. The tank has a corrosion-resistant stainless steel water connection, a butyl-rubber diaphragm and a polyurethane paint finish over an epoxy primer. It is suitable for potable-water systems.

The tank can also be used for suitably designed thermal-expansion applications. Match the tank to the system’s temperature and pressure requirements.

Maximum working pressure is 1000 kPa (145 psi). The tank stands upright on its own base. Place floor-mounted tanks on a firm base and support connected pipework.

Set the air charge to suit the pump/controller and system pressures. Release water pressure before checking or adjusting the air charge, and follow the instructions for the actual tank and control type.

Five-year manufacturer tank-replacement guarantee, subject to its terms.

Franklin Pressure Tank Product Information

✓ Application
Water storage under pressure for potable-water supply, irrigation and pressure boosting.
Thermal expansion in suitably designed systems.

✓ Warranty
Five-year manufacturer tank-replacement guarantee, subject to its terms.

✓ Model Specifications
Stock code: 106435104.
Nominal tank capacity: 35L.
Maximum working pressure: 1000 kPa (145 psi).
Water connection: 1" BSP male thread.
Mounting: vertical floor mounted.

✓ Draw-off & Sizing
Nominal tank capacity is not the usable water draw-off.
Usable draw-off depends on pump start/stop pressures and tank air charge.
Select for the system’s required draw-off and pump cycling limits.

✓ Construction
Butyl-rubber diaphragm separates water and air.
Stainless steel water connection.
Polyurethane paint finish over epoxy primer.

✓ Installation & Mounting
The tank stands upright on its own base.
Support the tank and pipework for the selected configuration.

✓ Air Charge & Controls
Air charge must suit the pump/controller and system pressures.
Follow the actual tank and controller instructions.
Release water pressure before checking or adjusting air charge.
Torrium2 Pump Control - Pre Wired 450kPa max

Davey Torrium2 provides automatic pump control for clean-water household supply, irrigation and water transfer. It starts the pump when water use causes pressure to fall, keeps it running while water is being used, and stops it when flow falls below about 1LPM. Pre-wired and plug-and-play versions provide different ways to connect the pump motor.

Inlet: 1" BSP male thread.
Outlet: 1" BSP male thread. The horizontal outlet rotates to suit the pipework; a vertical outlet is also available.

Maximum controller system pressure is 1000 kPa. Water temperature must remain between 1°C and 70°C; maximum ambient temperature is 50°C. Use clean, non-volatile liquids without fibres or solids. Other applications include washing systems and pressure boosting.

The controller version must suit the pressure the pump can produce with all outlets closed, as well as the pump’s electrical load. The 1000 kPa rating is the controller’s pressure limit; it does not mean every version suits a pump that produces that pressure.

When you close a tap, flow falls and the pump builds pressure before Torrium2 stops it. The controller remembers the pressure reached. Next time water is used, it normally restarts the pump once pressure has fallen by about 20% from that remembered value. This sets the restart point automatically. A dripping tap or slowly leaking toilet cistern releases water a little at a time, so pressure falls slowly. Torrium2 can wait until the pressure has fallen further before restarting the pump, increasing the time between starts. When normal water use resumes, it returns to its normal starting behaviour.

Dry-run protection stops the pump when Torrium2 detects a loss of prime. This means the pump no longer has enough water inside it to pump normally, which can happen if a supply tank empties or air enters the suction pipe. Torrium2 then retries at increasing intervals. The controller also stops the pump if water becomes too hot or it detects excessive electrical current. Lights show whether the pump is running, standing by or has a fault.

A small internal spring-loaded chamber holds a little water under pressure, helping reduce repeated starts during very small water draws. It does not need air-charge checks. An optional pressure tank up to 18L can be fitted to the vertical outlet to store more water between pump starts.

The housing is glass-fibre-reinforced nylon, with a 316 stainless steel sensor plate and nitrile O-rings. A built-in check valve helps retain pressure when the pump stops. A built-in surge protector helps protect the controller electronics from power spikes.

The controller has a 2m incoming power lead with an Australian three-pin plug. Match the motor connection to the selected pre-wired or plug-and-play version. Plug-and-play pump sockets need suitable weather protection outdoors.

Mount the controller with access to the priming point, prime button and status lights.

Two-year Davey warranty, subject to its terms.

Davey Torrium2 Controller Specifications
Davey Torrium2 Plug & Play Specifications
Davey Torrium2 Installation & Operating Instructions

✓ Application
Automatic pump start/stop control for household clean-water supply, irrigation, transfer, washing and pressure boosting.
Use clean, non-volatile liquids without fibres or solids.

✓ Warranty
Two-year Davey warranty, subject to its terms.

✓ Model Specifications
Pre-wired version
Motor connection must match the pump installation.

✓ Inlet & Outlet Connections
Inlet: 1" BSP male thread.
Horizontal outlet: 1" BSP male thread; rotating connection.
Vertical outlet: 1" BSP male thread; can accept an optional tank up to 18L.

✓ Operating Limits & Selection
Maximum controller system pressure: 1000 kPa.
Match the actual version to the pressure the pump can produce with all outlets closed and the total system pressure.
Manufacturer flow capacity: up to 200LPM; pressure loss increases with flow.
Water temperature: 1°C to 70°C.
Maximum ambient temperature: 50°C.

✓ Automatic Operation
Starts when water use causes pressure to fall.
Keeps the pump running while water is being used.
Stops when flow falls below approximately 1LPM.
Normally restarts after a 20% drop from the pressure remembered when the pump last stopped.
For a dripping tap or leaking cistern, can wait for pressure to fall further so the pump starts less often.
Returns to normal starting behaviour when normal water use resumes.

✓ Pump Protection
Stops the pump when it detects loss of prime: insufficient water in the pump for normal pumping.
Automatic retry at increasing intervals.
Water over-temperature and excessive-current shutdown.
Standby, running and fault lights.
Built-in surge protector for the controller electronics; protection can be exhausted by surges.

✓ Pressure Tank
Internal spring-loaded water chamber provides a small reserve between starts.
No air-charge maintenance for the internal chamber.
Optional external pressure tank up to 18L can mount on the vertical outlet.

✓ Construction
Glass-fibre-reinforced nylon housing.
316 stainless steel sensor plate.
Nitrile O-rings and built-in check valve.
Santoprene accumulator diaphragm and spring-loaded storage chamber.

✓ Electrical Supply & Connections
Single-phase AC; controller datasheet voltage range: 110–240V ±10%, 50/60Hz.
Maximum load current: 10A.
2m incoming power lead with Australian three-pin plug.
Pre-wired and plug-and-play motor connection options.
Plug-and-play pump sockets need suitable protection outdoors.

✓ Dimensions & Weight
Torrium2: 211mm high × 127mm wide; net weight 1.75kg.
Franklin MH Pump Base & Cover Kit — Cream

This Franklin MH kit includes a poly pump base and removable cover in Cream. The base supports the pump installation, while the cover fits over the pump and can be lifted off for access. It suits Franklin MH multistage pumps; the pump is sold separately.

Colour: Cream.

Allow space for the pump, connected pipework and controls, and keep the cover’s ventilation openings clear. The cover needs to remain removable for inspection and servicing.

One-year Franklin Electric accessory warranty, subject to its terms.

✓ Application
Base and protective cover for Franklin MH multistage pump installations.

✓ Warranty
One-year Franklin Electric accessory warranty, subject to its terms.

✓ Included Components
Matching poly pump base and removable cover.

✓ Construction
Poly base and cover.
Removable cover with ventilation openings.

✓ Installation
Allow clearance for the pump, pipework and controls.
Keep ventilation openings clear and retain access for servicing.
Brass 5-Way Pump Manifold — 1" BSP

This brass five-way manifold brings the pump delivery connection, pipework and pressure-control fittings together in one compact fitting. Its three 1" BSP ports provide the main water connections, while two smaller 1/4" BSP ports connect pressure-control accessories such as a pressure switch and gauge. It suits Franklin Electric MH-series pump installations.

The manifold provides connection points for a pump pressure system. The pressure switch controls when the pump starts and stops; a gauge shows system pressure. These components connect to the manifold and are sold separately.

The 1" BSP male and female ports are in line, with a second 1" BSP female port branching off at 90°. The two 1/4" BSP side ports face opposite directions: one male and one female.

✓ Application
Combining water and pressure-control connections in Franklin Electric MH-series pump installations.

✓ Connections
Main run: 1" BSP male and female ports in line.
Side branch: 1" BSP female port at 90° to the main run.
Accessory ports: opposing 1/4" BSP side ports, one male and one female.

✓ Construction
Brass five-way manifold.
PVC Bore Casing Bottom Plug — 100mm, Class 9–12

These PVC plugs fit inside the bottom of the bore casing, so they don’t stick out like a cap fitted over the pipe. This helps prevent the end from catching on the sides of the hole as the casing is lowered into the bore. Choose 100mm, 125mm or 150mm to suit Class 9–12 casing.

Sizes: 100mm, 125mm and 150mm.

The plug fits inside the casing rather than over its outside, maintaining a slim end profile for lowering. It also closes the bottom against material entering through the open end; water enters through the bore’s intended intake or screen section. Match the plug to the casing size and class.

✓ Application
Closing the lower end of compatible PVC bore casing while reducing catching during lowering.

✓ Size & Compatibility
Nominal sizes: 100mm, 125mm and 150mm.
Compatible casing class: Class 9–12.

✓ Construction
PVC bottom-end plug.
Fits inside the casing rather than over the outside of the pipe.
BoreSaver Ultra C Bore Cleaner — 10kg

BoreSaver Ultra C dissolves iron-oxide build-up and helps remove the associated bacterial slime from bores, pumps and pipework. It is used to rehabilitate an existing bore by loosening deposits so they can be flushed out, helping recover performance lost to iron build-up. This 10kg bucket contains the concentrated crystalline cleaner.

Iron-related bacteria can contribute to rusty, slimy deposits around bore screens and inside pumps and pipework, restricting water flow. Treatment dissolves the iron build-up and helps loosen the associated bacterial slime so it can be pumped out and flushed away.

The quantity needed depends on the bore’s internal diameter, the depth of water being treated and the amount of build-up. Select the treatment amount and method using the Australian application instructions.

Cleaning involves distributing the treatment through the affected area, allowing time for it to work, then pumping out the loosened material and flushing the system. The chosen method determines which parts of the bore and pump are reached.

Follow the product label, application instructions and current safety data sheet for handling, protective equipment and disposal of treatment water.

BoreSaver Ultra C Australian Application Instructions (2022)

✓ Application
Removing iron-oxide build-up and associated bacterial slime from groundwater bores, wells, pumps and pipework.

✓ Product & Pack
BoreSaver Ultra C.
Concentrated crystalline cleaner.
Net contents: 10kg bucket.

✓ Treatment Selection
Quantity depends on bore internal diameter, treated water depth and deposit severity.
Treatment method must reach the affected parts of the bore and pumping system.

✓ Use & Handling
Follow the Australian application instructions and product label.
Pump out deposits and flush after treatment as instructed.
Use the current matching safety data sheet for handling and disposal.