Grundfos CM pressure-switch booster assembly
Grundfos CM pressure-switch booster assembly
Grundfos CM pressure-switch booster assembly

GRUNDFOS CMB 3-37 PRESSURE-SWITCH BOOSTER PUMP

The Grundfos CMB 3-37 is a fixed-speed multistage booster for clean-water supply, irrigation and light commercial or agricultural use. The pressure switch starts and stops the pump automatically. A suitable pressure tank is required and is supplied separately.

✓ Rated duty: 51.7LPM at 27.4m head
✓ Maximum pump head: 36.6m
✓ Motor output: 0.5kW
✓ Inlet: 1" BSP female thread
✓ Outlet: 1" BSP male thread
✓ Adjustable start and stop pressures
✓ Pressure tank required, supplied separately
✓ Power supply: 220-240V single phase, 50Hz

Rated duty pairs show flow at the stated head; they are not maximum-flow ratings.

Grundfos CM Pump Installation & Operating Instructions
Grundfos CM-PS & CM-PT Pressure-Switch Instructions

Grundfos CM pressure-switch booster assembly

The Grundfos CMB 3-37 uses a 0.5kW fixed-speed multistage pump for household, irrigation, agricultural and light commercial water supply.

rated duty 51.7LPM at 27.4m head.

The pump has a 1" BSP female inlet. The system outlet is a 1" BSP male thread.

A suitable pressure tank is required and is supplied separately. It stores water under pressure, allowing small amounts of water to be drawn before the pump needs to restart.

Supplied with a pressure switch that automatically starts the pump when water pressure falls and stops it when pressure rises.

Rated duty pairs show flow at the stated head; they are not maximum-flow ratings.

Flow decreases as head increases. Select the pump for the required flow and pressure, allowing for inlet conditions, height differences and losses through fittings and pipework.

Use clean fresh water without solid particles or fibres, at temperatures from 0°C to 60°C.

These pumps are not self-priming. Before starting, fill the pump casing and inlet pipe with clean water, following the installation instructions. Maximum suction lift is 1m at 20°C, including inlet pipe losses. Install in a ventilated, weather-protected position with drainage and protection from frost.

An installer can adjust the start and stop pressures to suit the system, within the pump’s capacity and the pressure tank’s limits.

Switch start-pressure adjustment range: 100-500kPa.
These are switch adjustment limits, not the pressures the pump can necessarily deliver. The stop pressure must be achievable by the pump and below both its 1000kPa operating limit and the tank’s pressure limit.

The pump housing, impellers and shaft are stainless steel, with polymer diffusers. A pressure switch, pressure gauge, five-way fitting and non-return valve are supplied. The single-phase motor has thermal overload protection.

Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

Grundfos CM Pump Installation & Operating Instructions
Grundfos CM-PS & CM-PT Pressure-Switch Instructions

✓ Application
The Grundfos CMB 3-37 uses a 0.5kW fixed-speed multistage pump for household, irrigation, agricultural and light commercial water supply.

✓ Warranty
Two-year Grundfos Australian consumer warranty from purchase, subject to its terms.

✓ Model Specifications
CMB 3-37
Rated duty: 51.7LPM at 27.4m head (manufacturer reference at 2900rpm).
Maximum pump head: 36.6m.
Inlet: 1" BSP female thread.
System outlet: 1" BSP male thread.
Motor output P2: 0.5kW.

✓ Supplied Equipment & Tank Requirements
A suitable pressure tank is required and is supplied separately. It stores water under pressure, allowing small amounts of water to be drawn before the pump needs to restart.
A pressure switch, pressure gauge, five-way fitting and non-return valve are supplied.

✓ Performance
Flow decreases as head increases. Select the pump for the required flow and pressure, allowing for inlet conditions, height differences and losses through fittings and pipework.
Maximum head is not the pressure available at every flow.
Rated duty pairs show flow at the stated head; they are not maximum-flow ratings. Manufacturer reference speed: 2900rpm.

✓ Pressure Limits
Maximum operating pressure: 1000kPa.
Inlet pressure plus pump pressure must remain within this limit.

✓ Water Supply
Use clean fresh water without solid particles or fibres, at temperatures from 0°C to 60°C.

✓ Installation & Priming
These pumps are not self-priming. Before starting, fill the pump casing and inlet pipe with clean water, following the installation instructions. Maximum suction lift is 1m at 20°C, including inlet pipe losses. Install in a ventilated, weather-protected position with drainage and protection from frost.

✓ Control & Adjustment
Supplied with a pressure switch that automatically starts the pump when water pressure falls and stops it when pressure rises. An installer can adjust the start and stop pressures to suit the system, within the pump’s capacity and the pressure tank’s limits.
These are switch adjustment limits, not the pressures the pump can necessarily deliver. The stop pressure must be achievable by the pump and below both its 1000kPa operating limit and the tank’s pressure limit.

CMB 3-37
Switch start-pressure adjustment range: 100-500kPa.
Switch range only; usable settings depend on pump capacity and pump/tank pressure limits.

✓ Tank Precharge
Tank precharge is the gas pressure in the tank when its water side is depressurised. Set it to 90% of the pump cut-in pressure, following the tank instructions, and recheck it whenever the switch settings change.

✓ Construction
The pump housing, impellers and shaft are stainless steel, with polymer diffusers. The single-phase motor has thermal overload protection.

✓ Electrical Supply
Power supply: 220-240V single phase, 50Hz.
Built-in single-phase motor thermal protection.

✓ Electrical & Physical Details
CMB 3-37
Power supply: 220-240V single phase, 50Hz.
Maximum current consumption: 3.1-2.8A.
Rated motor speed: 2730-2740rpm.
Net weight: 14.4kg.
Manufacturer product number: 98244556.