Davey HP 65-06T (100 LPM Max Flow, 300 kPa Max Pressure)
Davey HP series performance curves for HP45-05T, HP65-06T and HP85-08T
Davey HP series performance curves for HP45-05T, HP65-06T and HP85-08T
Davey HP 65-06T (100 LPM Max Flow, 300 kPa Max Pressure)
Davey HP series performance curves for HP45-05T, HP65-06T and HP85-08T

DAVEY HP PRESSURE PUMPS WITH TORRIUM2

Davey HP45-05T and HP65-06T twin-stage pressure pumps supply clean water automatically for household taps, showers and garden watering. Their stainless steel pump casings and two-stage design provide pressure for household water supply and irrigation. Each comes with a Torrium2 controller that starts and stops the pump as water is used and helps reduce repeated starts at low demand.

✓ HP65-06T: up to 100 LPM; approximately 32m maximum head
✓ HP45-05T: up to 70 LPM; approximately 33m maximum head
✓ Inlet: 1 1/4" BSP female thread
✓ System outlet: 1" BSP male thread
✓ Maximum system pressure: 450kPa
✓ Power supply: 220-240V single phase, 50Hz

Davey HP45-05T & HP65-06T Specifications
Davey Torrium2 Controller Specifications
Davey Torrium2 Installation & Operating Instructions

Davey HP 65-06T (100 LPM Max Flow, 300 kPa Max Pressure)

Davey HP45-05T and HP65-06T twin-stage pressure pumps provide automatic clean-water supply for household use, irrigation, water transfer and washing systems. Their Torrium2 controllers start and stop the pumps as water is used.

Both pumps use a 1 1/4" BSP female inlet and deliver through a 1" BSP male Torrium2 outlet.

They handle clean, non-volatile liquids without fibres or solids at water temperatures from 1°C to 50°C.

The supplied Torrium2 controller automatically starts the pump when water pressure falls and stops it when water demand ends. It automatically sets the starting pressure to suit the pump and installation, adapting during very low demand to reduce repeated starts. Its built-in accumulator allows a small amount of water to be drawn before the pump restarts.

The two-stage pump design uses a 304 stainless steel casing and backplate, glass-filled Noryl stage body and glass-filled polycarbonate impellers. The motor shell is marine-grade aluminium with a baked polyester finish.

Loss-of-prime protection stops the pump if its water supply is lost, with automatic retry to check whether water has returned. The controller also provides high-water-temperature and excessive-current cut-outs. The motor has its own automatic-reset thermal overload protection.

Install horizontally on a firm base in a ventilated, weather-protected position with drainage. Fill the pump casing and suction line with water before starting. Suction-lift installations require a foot valve to retain prime. The maximum suction lift is 6m; actual performance depends on the suction pipework and installation.

Each complete pressure system has a 450kPa maximum system pressure limit and uses a 220-240V single-phase, 50Hz supply.

Two-year Davey warranty, subject to its terms.

Davey HP45-05T & HP65-06T Specifications
Davey Torrium2 Controller Specifications
Davey Torrium2 Installation & Operating Instructions

✓ Application
Automatic household water supply, irrigation, water transfer and washing systems.

✓ Warranty
Two-year Davey warranty, subject to its terms.

✓ Model Specifications

HP65-06T
Twin-stage centrifugal pressure pump.
Maximum flow: 100 LPM.
Maximum total head: approximately 32m.
Approximate curve readings:
40 LPM: approximately 30m total head.
60 LPM: approximately 26m total head.
80 LPM: approximately 21m total head.
Pump inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP male thread (through Torrium2).
Motor output power P2: 0.6kW.
Pump casing and backplate: 304 stainless steel. Stage body: glass-filled Noryl.

HP45-05T
Twin-stage centrifugal pressure pump.
Maximum flow: 70 LPM.
Maximum total head: approximately 33m.
Approximate curve readings:
20 LPM: approximately 32m total head.
40 LPM: approximately 29m total head.
60 LPM: approximately 22m total head.
Pump inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP male thread (through Torrium2).
Motor output power P2: 0.55kW.
Pump casing and backplate: 304 stainless steel. Stage body: glass-filled Noryl.

✓ Outlet Connections
Torrium2 provides horizontal and vertical outlets.

✓ Performance
Flow decreases as head increases.
HP shut-off heads and the flow-at-head examples are approximate readings from the 50Hz curves.
Expected flow depends on vertical lift and pipe resistance.

✓ Automatic Control
Torrium2 uses pressure and flow sensors to start the pump when pressure falls and stop it when water demand ends. It normally restarts at approximately 80% of the previous shut-off pressure and adapts the start pressure during very low demand to reduce repeated starts. A built-in spring-loaded accumulator provides a small amount of draw-off water.

✓ Pump & Motor Protection
Loss-of-prime protection stops the pump if its water supply is lost, with automatic retry to check whether water has returned. The controller also provides high-water-temperature and excessive-current cut-outs. The motor has its own automatic-reset thermal overload protection.

✓ Pressure Limits
Maximum system pressure: 450kPa for both complete systems.

✓ Water Supply
Clean, non-volatile liquids without fibres or solids.
Water temperature: 1°C to 50°C.

✓ Installation & Priming
Mounting: two 10mm holes at 140mm centres.
Install horizontally on a firm base in a ventilated, weather-protected position with drainage. Fill the pump casing and suction line with water before starting. Suction-lift installations require a foot valve to retain prime. The maximum suction lift is 6m; actual performance depends on the suction pipework and installation.

✓ Construction
Glass-filled polycarbonate impellers.
303 stainless steel pump shaft.
Ceramic/carbon mechanical seal with nitrile O-rings.
Marine-grade aluminium motor shell with baked polyester finish.
Glass-fibre-reinforced nylon Torrium2 housing.

✓ Electrical Supply
Maximum ambient temperature: 50°C.
220-240V single phase, 50Hz.
Nominal speed: 2850rpm.
Locked-rotor current: 12A for each model.
Permanent split capacitor starting.
Motor enclosure: IP55.
Torrium2 controller enclosure: IP56.
Motor insulation: Class F.
Controller power lead: 2m with Australian three-pin plug.

✓ Electrical & Physical Details

HP65-06T
Input power P1: 0.9kW.
Full-load current: 3.8A.
Overall length: 329mm.
Overall width: 170mm.
Overall height: 328mm.
Net weight: 9kg.

HP45-05T
Input power P1: 0.77kW.
Full-load current: 3.4A.
Overall length: 329mm.
Overall width: 170mm.
Overall height: 328mm.
Net weight: 9kg.

Recently viewed