Franklin MultiStage Transfer Pump 3AMH2B-51, 50LPM, 0.33KW - Single Phase
Franklin MH3 original manufacturer performance curves at 50Hz
Franklin MH3 original manufacturer performance curves at 50Hz
Franklin MultiStage Transfer Pump 3AMH2B-51, 50LPM, 0.33KW - Single Phase
Franklin MH3 original manufacturer performance curves at 50Hz

FRANKLIN MH3 HORIZONTAL MULTISTAGE TRANSFER PUMPS

Franklin MH3 horizontal multistage pumps supply clean water for water transfer, pressure boosting, irrigation and washdown. Choose the stage count for the required flow and pressure, then select single-phase or three-phase supply. These are bare pump-and-motor units; automatic start/stop operation requires separate controls, and no pressure tank is included.

✓ 3AMH2B: 50LPM at 15.5m head; maximum head 22.4m
✓ 3AMH3B: 50LPM at 22.5m head; maximum head 33.2m
✓ 3AMH4B: 50LPM at 29.1m head; maximum head 43.7m
✓ 3AMH5B: 50LPM at 35.2m head; maximum head 54m
✓ 3AMH6B: 50LPM at 42.8m head; maximum head 65.1m
✓ 3AMH7B: 50LPM at 48.7m head; maximum head 75.3m
✓ 3AMH8B: 50LPM at 58.8m head; maximum head 87.6m
✓ 3AMH9B: 50LPM at 65.2m head; maximum head 98m
✓ Inlet: 1 1/4" BSP female thread
✓ Outlet: 1" BSP female thread
✓ Single-phase and three-phase options; select the correct electrical supply
✓ Not self-priming; fill pump and suction pipe before starting

Franklin MH Pump Installation & Operating Manual

Franklin MultiStage Transfer Pump 3AMH2B-51, 50LPM, 0.33KW - Single Phase

Franklin MH3 horizontal multistage pumps supply clean water for water transfer, pressure boosting, irrigation and washdown. Choose the stage count for the required flow and pressure, then select single-phase or three-phase supply.

These listings are for bare pump-and-motor units. Suitable separate controls are required for automatic operation as taps open and close; a pressure tank is not included.

3AMH2B: 50LPM at 15.5m head; maximum head 22.4m.
3AMH3B: 50LPM at 22.5m head; maximum head 33.2m.
3AMH4B: 50LPM at 29.1m head; maximum head 43.7m.
3AMH5B: 50LPM at 35.2m head; maximum head 54m.
3AMH6B: 50LPM at 42.8m head; maximum head 65.1m.
3AMH7B: 50LPM at 48.7m head; maximum head 75.3m.
3AMH8B: 50LPM at 58.8m head; maximum head 87.6m.
3AMH9B: 50LPM at 65.2m head; maximum head 98m.

The paired figures show flow at a stated head. Maximum head occurs at zero flow, separately from the listed flow. Allow for inlet conditions, height differences and pipe losses when selecting the pump.

Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.

The pump body, impellers and diffusers are 304 stainless steel. Use clean water without solid particles or fibres, compatible with the pump materials. Maximum water temperature is 55°C for single-phase models and 85°C for three-phase models in domestic and commercial use. The higher 110°C three-phase limit is for industrial applications only.

The pump is not self-priming. Fill the pump casing and suction pipe before starting, and use suitable inlet valves to retain prime where suction lift is required. Install on a firm base with drainage, supported pipework, ventilation and protection from weather and freezing. Do not run without water or against a closed outlet.

Maximum operating pressure is 1000kPa; inlet pressure and the pressure added by the pump must remain within this limit.

Single-phase versions use a 220–240V, 50Hz supply, have an AU/NZ plug and include motor thermal overload protection. Three-phase versions use a 380–415V, 50Hz supply and require an electrician connection and external motor protection.

Two-year Franklin Electric pump warranty, subject to its terms.

Franklin MH Pump Installation & Operating Manual

✓ Application
Clean-water transfer, pressure boosting, domestic water supply, garden irrigation and washdown.

✓ Warranty
Two-year Franklin Electric pump warranty, subject to its terms.

✓ Model Specifications
3AMH2B
Flow/head reference: 50LPM at 15.5m head.
Maximum pump head: 22.4m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH2B-51 single phase, 3AMH2B-53 three phase.

3AMH3B
Flow/head reference: 50LPM at 22.5m head.
Maximum pump head: 33.2m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH3B-51 single phase, 3AMH3B-53 three phase.

3AMH4B
Flow/head reference: 50LPM at 29.1m head.
Maximum pump head: 43.7m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH4B-51 single phase, 3AMH4B-53 three phase.
Single-phase motor output P2: 0.55kW.

3AMH5B
Flow/head reference: 50LPM at 35.2m head.
Maximum pump head: 54m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH5B-51 single phase, 3AMH5B-53 three phase.
Motor output P2: 0.75kW for the listed versions.

3AMH6B
Flow/head reference: 50LPM at 42.8m head.
Maximum pump head: 65.1m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH6B-51 single phase, 3AMH6B-53 three phase.

3AMH7B
Flow/head reference: 50LPM at 48.7m head.
Maximum pump head: 75.3m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH7B-51 single phase, 3AMH7B-53 three phase.
Motor output P2: 1.1kW for the listed versions.

3AMH8B
Flow/head reference: 50LPM at 58.8m head.
Maximum pump head: 87.6m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH8B-51 single phase, 3AMH8B-53 three phase.

3AMH9B
Flow/head reference: 50LPM at 65.2m head.
Maximum pump head: 98m (zero flow).
Inlet: 1 1/4" BSP female thread.
Outlet: 1" BSP female thread.
Stocked versions: 3AMH9B-51 single phase, 3AMH9B-53 three phase.
Motor output P2: 1.5kW for the listed versions.

✓ Supplied Operation
Bare pump-and-motor unit; pressure tank and automatic demand controls are supplied separately.
The pump does not automatically start and stop as taps open and close without suitable separate controls.

✓ Performance & Pressure Limits
The paired figures show the flow available at a stated head.
Application flow range: 25–75LPM; select the stage count for the required head.
Maximum head is the zero-flow figure and occurs separately from the listed flow.
Maximum operating pressure: 1000kPa. Inlet pressure plus pump pressure must remain within this limit.
Select the pump for the required flow and head, allowing for height differences and pipe losses.
Do not run against a closed outlet or below the manufacturer's minimum operating flow.

✓ Water Supply
Clean, non-aggressive liquids compatible with the pump materials, without solids or fibres.
Maximum water temperature: single phase 55°C; three phase 85°C for domestic/commercial use, or 110°C for industrial use only.

✓ Installation & Priming
Not self-priming; fill the pump casing and suction pipe with water before starting.
Use suitable inlet valves to retain prime in suction-lift installations; check the suction conditions against the pump curve.
Install on a firm base with supported pipework, drainage and protection from weather and freezing.
Leave at least 100mm clearance at the motor cooling fan, following the manual.
Provide suitable protection against loss of water supply; do not run dry.

✓ Construction
304 stainless-steel pump body, impellers and diffusers.
Standard MH3/MH5 seal: ceramic/carbon with EPDM elastomer.
Horizontal close-coupled multistage construction.

✓ Electrical Supply & Protection
Single phase: 220–240V, 50Hz, with AU/NZ plug and built-in thermal overload protection.
Three phase: 380–415V, 50Hz; requires external overload protection and connection by an electrician.
Maximum ambient temperature: 40°C.
Motor insulation: Class F. Refer to the supplied motor nameplate for its enclosure rating, output and current.