The Hunter HPC Wi-Fi Modular 4 Station Base Controller combines built-in Hydrawise control with modular expansion for residential and light commercial irrigation. App and web access provide remote management and weather-based adjustment, while the full-colour touchscreen provides on-site control and offline programming.
The controller includes four conventional stations and a separate P/MV output for a master valve or pump start relay. The table shows the modules added to this four-station base to reach each final conventional station count. Expansion modules are purchased separately.
Conventional station expansion
Totals include the four stations supplied with the controller. Expansion modules are purchased separately.
| Total stations | Modules to add |
|---|---|
| 4 stations | No expansion module |
| 7 stations | 1 x PCM-300 |
| 10 stations | 2 x PCM-300 |
| 13 stations | 3 x PCM-300 |
| 16 stations | 1 x PCM-300 + 1 x PCM-900 |
| 23 stations | 1 x PCM-300 + 1 x PCM-1600 |
Install PCM-300 in the first expansion slot before PCM-900 or PCM-1600. The PCM-900 or PCM-1600 then occupies the upper two expansion slots.
The optional PC-DM module and EZ-1 or EZ-LR field decoders enable two-wire operation, where a shared pair of wires connects the controller to decoders at the valves. Capacity is up to 32 total stations: four conventional outputs and up to 28 decoder stations. Adding one PCM-300 changes this to seven conventional outputs and up to 25 decoder stations. PC-DM occupies the upper two expansion slots, so it replaces the PCM-900 or PCM-1600 arrangement. The module and decoders are purchased separately.
Standard Hydrawise programming provides 6 independent programs with 6 start times per program and station run times up to 24 hours.
Online Hydrawise functions require a suitable 2.4 GHz Wi-Fi network and internet access. Advanced Hydrawise programming offers station-based scheduling with up to six total start times. This differs from the standard program-based mode.
Cycle and Soak and seasonal adjustment provide further watering control. Two sensor inputs support compatible Clik sensors or an added HC Flow Meter for water-use monitoring and flow alerts. Built-in milliamp sensing detects wiring faults, and non-volatile memory retains irrigation programming.
The HPC-FP is available separately to replace a faulty HPC front panel. It can also upgrade compatible Pro-C controllers manufactured March 2014 or newer to Hydrawise. Panel only.
2 Year Hunter Warranty.
Controller and expansion documents
Hunter Hydrawise Wi-Fi Network Requirements & Troubleshooting
Hunter HPC Controller Specifications
Hunter HPC Controller Installation Guide
Hunter HPC Controller Door Card
Hunter HPC Controller PCM-1600 Expansion Module Installation Guide
Hunter HPC Controller PC-DM Decoder Module Installation Guide
EZ Decoder System documents - for optional PC-DM installation
Hunter EZ Decoder System Brochure
Hunter EZ Decoder System Specifications
Hunter EZ-1 Decoder Installation Guide
Hunter EZ-LR Decoder Installation Guide
HPC-FP replacement panel
Hunter HPC-FP Replacement / Retrofit Panel Specifications
How watering programs work
In standard Hydrawise programming, the HPC has six separate watering programs. Each program is its own watering schedule, with separate watering days, start times and station run times.
Each station controls a watering zone, such as a lawn or garden bed. Within each program, select the stations to water and set how long each one runs. Station run times can be set up to 24 hours.
Each program allows up to six start times on its selected watering days. Each start time begins the whole program, watering its stations one after another for their set run times.
For example, one program could start at 6am, water the lawn for 10 minutes, then water a garden bed for 5 minutes. That needs one start time. Add another start time to repeat the same sequence later that day. The other programs can have their own schedules. Use only the programs and start times you need.
Avoiding common programming mistakes
- Avoid unintended repeat cycles. One start time runs the whole program. Each additional start repeats it. Disable or remove starts you do not need.
- Check all programs. A station included in more than one active program can water again under each schedule. Keep it in multiple programs only when that extra watering is intended.
- Space start times for the whole cycle. Allow time for the complete watering cycle, including all stations and any programmed delays, before scheduling another start.
How two-wire decoder wiring works
Conventional valve wiring uses a separate station wire from the controller to each watering station, together with a shared common wire. A two-wire decoder system uses a shared pair of field wires to carry power and control signals to decoders near the valves.
The PC-DM output module fits inside the compatible controller. Each EZ-1 or EZ-LR field decoder connects to the shared cable and a local valve solenoid. It is programmed with a station number. Starting that station operates the valve connected to its decoder.
The cable can branch in different directions to reach separate valve locations. At each split, join each conductor separately using suitable waterproof irrigation connectors inside a valve box. Both branches remain part of the shared two-wire path.
With a compatible four-station base, PC-DM provides decoder stations 5 to 32. Stations 1 to 4 remain conventional outputs. Adding one PCM-300 extends the conventional outputs to station 7 and moves the decoder range to stations 8 to 32. These share a 32-station total. Follow the PC-DM guide for module placement.
Choose cable size for the distance to the furthest decoder and the number of solenoids running at the same time on the shared path. More simultaneous solenoids reduce the permitted distance. Include a master valve if it is operated through a decoder. Use the EZ-1 or EZ-LR wiring tables in the guides above.