HUNTER HCC MODULAR COMMERCIAL CONTROLLERS WITH HYDRAWISE WI-FI

Hunter HCC Wi-Fi modular controllers provide app and web control through built-in Hydrawise Wi-Fi, with an on-site touchscreen for local operation. ICM modules expand the eight-station base to 38 conventional stations in plastic cabinets or 54 in metal cabinets. The optional EZ-DM (ICC2 / HCC) output module and compatible EZ decoders support up to 54 total stations in both plastic and metal cabinet models. Online functions require Wi-Fi and internet access.

✓ 8 Station Base with Separate Pump / Master-Valve Output
✓ 6 Programs with 6 Start Times per Program in Standard Mode
✓ Station Run Times up to 24 Hours
✓ Conventional Expansion up to 38 Stations (Plastic) or 54 Stations (Metal) with ICM Modules
✓ Optional EZ-DM & EZ Decoders Enable up to 54 Total Stations
✓ Flow Monitoring. Separate Flow Meter Required
✓ 2 Year Hunter Warranty

Hunter HCC Controller Brochure
Hunter Hydrawise Wi-Fi Network Requirements & Troubleshooting
Hunter HCC Controller Specifications
Hunter HCC Controller Door Card

Hunter HCC Wi-Fi modular controllers provide automatic watering for larger gardens, commercial landscapes and municipal sites. Built-in Hydrawise Wi-Fi provides app and web management, weather-based adjustment and controller alerts. The 8cm full-colour touchscreen provides local programming and manual operation.

Standard Hydrawise programming provides 6 separate watering programs with 6 start times per program and station run times up to 24 hours. Advanced mode uses station-based scheduling with up to 6 total start times.

Up to two stations can operate at the same time, plus the separate pump/master-valve output. Plan overlapping watering only where the water supply and electrical load can support it.

The supplied ICM-800 module provides eight conventional station outputs. The controller also has a separate P/MV output for a master valve or pump start relay. Add ICM modules to expand to 38 conventional stations in plastic cabinets or 54 in metal cabinets. Additional ICM-400, ICM-800 and ICM-2200 modules provide four, eight and 22 more outputs respectively.

Conventional station expansion

Examples below show modules added to the supplied eight-station base. The factory-fitted ICM-800 is already included in that base and is not counted again. These are common configurations, rather than every possible combination.

Final conventional capacity Additional modules Plastic cabinet Metal cabinet
8 stations No additional module Yes Yes
12 stations 1 x ICM-400 Yes Yes
16 stations 1 x ICM-800 Yes Yes
24 stations 2 x ICM-800 Yes Yes
32 stations 3 x ICM-800 Yes Yes
38 stations 1 x ICM-800 + 1 x ICM-2200 Yes No
40 stations 4 x ICM-800 No Yes
48 stations 5 x ICM-800 No Yes
54 stations 3 x ICM-800 + 1 x ICM-2200 No Yes

Install standard modules in slot order. ICM-2200 is limited to one per controller and must occupy the last two slots: slots 3 and 4 in plastic cabinets, or slots 5 and 6 in metal cabinets. For the maximum-capacity ICM-2200 configurations shown, fill the earlier slots with ICM-800 modules. Press the Reset button on the back of the control panel after module changes so the controller recognises the new station count.

For two-wire operation, add an EZ-DM (ICC2 / HCC) output module and compatible EZ-1 or EZ-LR field decoders. All-decoder operation supports up to 54 stations. In a hybrid system, conventional and decoder outputs share the same 54 station numbers, rather than providing 54 extra stations on top of the conventional outputs. Keep conventional modules in the lower-numbered slots and install EZ-DM in the next available slot, as described in its guide. The EZ-DM page explains slot use, station assignments and the field-decoder options.

Flow monitoring, high/low-flow alerts and water-use reporting require a compatible HC Flow Meter, purchased separately and configured in Hydrawise. Two sensor inputs accept suitable flow or Clik sensors. Online weather adjustment, remote access and alerts require a suitable 2.4 GHz Wi-Fi network and internet connection. The controller can also be programmed at its touchscreen.

A prewired SmartPort supports optional ROAM or ROAM LR handheld remotes for on-site manual operation. The built-in milliamp sensor helps identify wiring faults and supports controller alerts.

Both the plastic and metal wall-mount cabinets are rated IP55 for outdoor installation. The plastic model is supplied corded. The controller operates compatible 24VAC irrigation solenoids from an internal transformer. Follow the installation instructions for power supply, mounting and wiring.

For an existing compatible ICC or ICC2 installation, the HCC-FPUP kit provides a retrofit route to Hydrawise. The HCC-FPUP kit can also replace a damaged HCC facepack, power module or ribbon cable. Match the replacement part numbers before ordering. See Hunter HCC / HCC-FPUP Installation and Quick Start Guide.

2 Year Hunter Warranty.

Controller documents
Hunter HCC Controller Brochure
Hunter Hydrawise Wi-Fi Network Requirements & Troubleshooting
Hunter HCC Controller Specifications
Hunter HCC Controller Door Card

Optional EZ Decoder System documents
Hunter EZ Decoder System Brochure
Hunter ICC2 / HCC Controller EZ-DM Decoder Module Installation Guide
Hunter EZ Decoder System Specifications
Hunter EZ-1 Decoder Installation Guide
Hunter EZ-LR Decoder Installation Guide

How watering programs work

In standard Hydrawise mode, the HCC has six separate watering programs. Each program is its own watering schedule, with its own watering days, start times and station run times.

Each station controls a watering zone, such as a lawn or garden bed. Within a program, choose the stations to water and set how long each one runs.

Each program allows up to six start times. One start begins the whole program, running its selected stations in sequence for their set run times. Another program can run at the same time where the controller and installation allow it.

For example, one program could start at 6am, water the lawn for 10 minutes, then a garden bed for 5 minutes. That needs one start time. Add another start time to repeat the same sequence later that day. Use only the programs and start times needed.

Avoiding common programming mistakes

  • Avoid unintended repeat cycles. Each additional start time repeats the whole program. Disable or remove starts you do not need.
  • Check all programs. A station included in more than one active program can water again under each schedule. Keep it in multiple programs only when that extra watering is intended.
  • Plan overlapping watering. This controller can run two stations at once. Overlapping schedules can therefore increase the flow required from the water supply. Allow for complete program durations and any master valve. For decoder wiring, count all solenoids running at the same time on the shared path when checking cable range.

How two-wire decoder wiring works

Conventional valve wiring uses a separate station wire from the controller to each watering station, together with a shared common wire. A two-wire decoder system uses a shared pair of field wires to carry power and control signals to decoders near the valves.

The EZ-DM output module fits inside the compatible controller. Each EZ-1 or EZ-LR field decoder connects to the shared cable and a local valve solenoid. It is programmed with a station number. Starting that station operates the valve connected to its decoder.

The cable can branch in different directions to reach separate valve locations. At each split, join each conductor separately using suitable waterproof irrigation connectors inside a valve box. Both branches remain part of the shared two-wire path.

EZ-DM supports up to 54 total stations in both plastic and metal cabinet models. In a hybrid installation, conventional outputs and decoder stations share those 54 station numbers. Assign decoders to numbers not already used by conventional outputs. Follow the EZ-DM guide for the module layout.

Choose cable size for the distance to the furthest decoder and the number of solenoids running at the same time on the shared path. More simultaneous solenoids reduce the permitted distance. Include a master valve if it is operated through a decoder. Use the EZ-1 or EZ-LR wiring tables in the guides above.

✓ Application
Automatic control of larger residential, commercial and municipal irrigation systems.

✓ Warranty
2 Year Hunter Warranty.

✓ Model & Station Capacity
Models in This Range: HCC-800-PL and HCC-800-M.
Included Station Module: One ICM-800 providing 8 conventional station outputs.
Pump / Master Valve: Separate P/MV output, additional to the station outputs.
Conventional Expansion: Up to 38 conventional stations in plastic cabinets or 54 in metal cabinets.
Decoder Expansion: Up to 54 total station numbers using EZ-DM and compatible field decoders.

✓ Programming & Watering Schedules
Standard Mode: 6 independent programs with 6 start times per program.
Advanced Mode: Station-based scheduling with up to 6 total start times.
Station Run Time: Up to 24 hours.
Scheduling: Hydrawise program-based or advanced station-based scheduling.
Weather Adjustment: Hydrawise online weather-based scheduling.
Manual Operation: Touchscreen and Hydrawise app/web controls.

✓ Control & Connectivity
Local Control: 8cm full-colour touchscreen.
Wi-Fi: Built-in Hydrawise connectivity.
Network: 2.4 GHz Wi-Fi, 802.11 b/g/n, 20 MHz. WPA/WPA2 Personal.
Internet Requirement: Required for online remote access, weather data and cloud alerts. Local touchscreen programming is available.

✓ Simultaneous Operation
Maximum: 2 stations plus pump/master valve.
System Design: Water supply and electrical loading must support any simultaneous operation.

✓ Conventional Expansion & Installation
Modules: ICM-400 adds 4 outputs. ICM-800 adds 8. ICM-2200 adds 22.
ICM-2200 Limit: One per controller.
ICM-2200 Position: Slots 3 and 4 in plastic cabinets. Slots 5 and 6 in metal cabinets.
ICM-2200 Maximum-Capacity Layout: ICM-800 modules in the preceding slots.
Plastic Maximum: Base 8 + one ICM-800 + one ICM-2200 = 38 conventional stations.
Metal Maximum: Base 8 + three ICM-800 + one ICM-2200 = 54 conventional stations.
Recognition: Follow the controller installation procedure after adding or changing modules.

✓ EZ Decoder Expansion
Required Equipment: EZ-DM output module with EZ-1 or EZ-LR field decoders.
All-Decoder Layout: Up to 54 decoder station numbers, plus pump/master-valve operation.
Hybrid Layout: Conventional outputs retain their station numbers. Decoders use the remaining numbers up to 54.
Example: Conventional stations 1–8 plus decoder stations 9–54 gives 8 conventional and up to 46 decoder stations.
Capacity Accounting: Both EZ-DM paths share the same 54-station range.
Module Position: Follow the EZ-DM guide for all-decoder and hybrid slot arrangements.

✓ Flow & Sensor Compatibility
Flow: Compatible HC Flow Meter enables flow monitoring, high/low-flow alerts and water-use reporting.
Flow Meter: Purchased separately.
Sensor Inputs: 2 for suitable Clik sensors or HC Flow Meter.

✓ Remote Compatibility
Handheld Remotes: Hunter ROAM and ROAM LR through the prewired SmartPort.

✓ Installation & Construction
Cabinet Options: Plastic or metal wall-mount. Plastic model supplied corded.
Exposure Rating: IP55 wall-mount enclosure for outdoor installation.
Compliance: RCM approved.

✓ Power Supply & Valve Outputs
Operating Supply: Australian 230VAC model with internal transformer.
Transformer Output: 24VAC, 1.4A.
Station Output: 24VAC, up to 0.56A per station.
P/MV Output: 24VAC, up to 0.56A.
Valve Type: Compatible 24VAC irrigation solenoids.

✓ Memory & Diagnostics
Diagnostics: Built-in milliamp sensor for wiring fault detection and controller alerts.

✓ Dimensions
Plastic: approximately 305mm high x 350mm wide x 127mm deep.
Metal: approximately 406mm high x 330mm wide x 127mm deep.

✓ Retrofit Kit
HCC-FPUP: Retrofit kit for compatible existing ICC or ICC2 controllers. Panel/module kit rather than a complete controller.