SOLENOID VALVES - RAIN BIRD

This Rain Bird DVF is fitted with a DC-latching coil for use with a compatible battery-operated irrigation controller. It includes a handle for adjusting water flow and a double-filtered pilot circuit to help keep debris out of the control passages.

✓ Connections: 25mm BSP
✓ Power: 9V DC-latching
✓ Flow Control: Adjustable water flow
✓ Pilot Filtration: Two filters help keep control passages clear

Rain Bird DV & DVF Specifications
Rain Bird DV & DVF User Manual
Rain Bird PGA Specifications
Rain Bird PGA User Manual

The Rain Bird DVF 25mm solenoid valve controls irrigation zones using a compatible battery-operated controller with a DC-latching output. Its easy-to-turn flow-control handle adjusts water flow at the valve.

The double-filtered pilot circuit helps keep debris out of the valve’s control passages. A captured solenoid plunger and captive diaphragm spring help prevent lost parts during servicing.

Internal manual bleed releases pressure above the diaphragm into the outlet pipe, allowing the valve to open without an electrical signal. Water stays within the pipework. Close the manual control after testing to return the valve to controller operation. The external bleed screw releases water outside the valve for flushing during installation and start-up. Keep it closed during normal controller operation.

For drip irrigation or flows below 12.5 L/min, install the upstream filter specified in the linked instructions.

Rain Bird DV & DVF Specifications
Rain Bird DV & DVF User Manual
Rain Bird PGA Specifications
Rain Bird PGA User Manual

✓ Product Type & Application
Rain Bird DVF 25mm Solenoid Valve with 9V DC-Latching Coil.

✓ Size & Connections
25mm BSP inlet and outlet.

✓ Electrical Operation
9V DC-latching coil. Requires a compatible controller providing opening and closing pulses.

✓ Flow Control & Manual Operation
Flow control: Easy-to-turn handle adjusts water flow at the valve.
Internal manual bleed: Releases pressure above the diaphragm into the outlet pipe. Close the manual control after testing.
External bleed screw: Allows flushing during installation and start-up; discharges outside the valve. Keep closed during normal controller operation.

✓ Pilot Filtration & Installation
Double-filtered pilot circuit with 200-micron solenoid and pilot-water filters. For drip irrigation or flows below 12.5 L/min, use the upstream filter specified in the installation instructions.

✓ Construction & Servicing
Buna-N diaphragm with captive spring. Captured solenoid plunger. Internal components accessible from above.

You may also like