Solvent Cement PVC-U Type P Green 250 ml
Solvent Cement PVC-U Type P Green 250 ml

PVC solvent cements join pipe and fittings by softening the prepared contact surfaces, which bond as the joint cures. The range includes Type P cements for pressure joints, Type N for non-pressure work, and clear Christy's cement. Choose the formulation to suit the pipe system and the required finish.

✓ Product type: PVC solvent cement
✓ Green Type P: 250ml and 500ml
✓ Iplex clear Type P: 500ml with brush
✓ Rapid Weld blue Type N: 250ml and 500ml
✓ Christy's clear: 236ml and 473ml
✓ Christy's Red Hot Green Type P: 236ml

Vinidex PVC Solvent Cement Jointing Guide
Iplex PVC Pressure Jointing Guide
Iplex Type P Clear Solvent Cement Safety Data Sheet
Christy's Solvent Cement Set & Cure Guide
Christy's Red Hot Green Safety Data Sheet

Solvent Cement PVC-U Type P Green 250 ml

Solvent cement forms a welded connection between a PVC pipe end and fitting socket. Its solvents soften and dissolve the prepared mating surfaces so they bond together during curing. Primer first cleans, degreases and softens the PVC to help the cement penetrate.

Green Type P cement and Iplex clear Type P cement are for pressure-pipe joints. The green formulation makes applied cement visible, while Iplex clear cement leaves no coloured cement line. Rapid Weld blue Type N cement is for non-pressure joints.

Christy's clear PVC cement provides a colourless finish for visible pipework. Christy's Red Hot Green is a separate fast-setting Type P formulation for pressure joints; a fast initial set still requires the specified curing period before pressure is applied.

Prepare and assemble each joint according to the selected cement and pipe-system instructions. Cure requirements vary with the formulation, pipe size and conditions.

Vinidex PVC Solvent Cement Jointing Guide
Iplex PVC Pressure Jointing Guide
Iplex Type P Clear Solvent Cement Safety Data Sheet
Christy's Solvent Cement Set & Cure Guide
Christy's Red Hot Green Safety Data Sheet

✓ Pressure Joint Cements
Green Type P: 250ml and 500ml.
Iplex clear Type P: 500ml with brush.
Christy's Red Hot Green Type P: 236ml, fast setting.

✓ Non-Pressure Joint Cements
Rapid Weld blue Type N: 250ml and 500ml.

✓ Clear PVC Cement
Christy's clear: 236ml and 473ml.

✓ Jointing & Preparation
Solvent-welded PVC pipe and fitting joints.
Prepare surfaces with the specified primer before cementing.
Follow the selected formulation's assembly and cure instructions.

✓ Included Brushes
Vinidex green Type P 250ml and 500ml: Brush included.
Vinidex blue Type N 250ml: Brush included.
Iplex clear Type P 500ml: Brush included.

✓ Vinidex Setting & Handling
Green Type P 250ml and 500ml; blue Type N 250ml:
Hold the assembled joint against movement for at least 30 seconds.
Leave the joint undisturbed for 5 minutes.
Avoid rough handling for at least 1 hour.
Wait at least 1 hour after the last joint before filling with water.

✓ Vinidex Type P Pressure Curing
Pressure-joint cure guide: Allow 24 hours at 16°C and above, or 48 hours at 0°C, before pressurising.
Curing depends on temperature and humidity; follow the cement and pipe-system instructions.

✓ Iplex Clear Type P Setting & Curing
Hold the assembled joint without movement for at least 30 seconds.
Leave undisturbed for at least a further 5 minutes.
Pressure-joint cure guide: Allow 24 hours at 16°C and above, or 48 hours at 0°C, before pressurising.
Curing depends on temperature and humidity; follow the cement and pipe-system instructions.

✓ Christy's General Set & Cure Guidance
Typical initial set before careful handling at 60-100°F (approximately 16-38°C):
1/2" to 1 1/4" pipe: 2-3 minutes.
1 1/2" to 3" pipe: 5 minutes.
These are general manufacturer estimates, not pressure-ready times or pipe-size approval limits.
Cure before service: Use the Christy's Set & Cure Guide for the pipe size, temperature during assembly and curing, and operating pressure.
Cure-table baseline: Relative humidity 60% or less.
Damp or humid conditions: Allow 50% more cure time; initial set may also require up to 50% longer.
Colder conditions and larger pipe sizes require different intervals; refer to the full guide.