Hunter Solenoid Valve 25mm PGV Square Bolt Top with Flow Control
Hunter Solenoid Valve 25mm PGV Square Bolt Top with Flow Control

HUNTER IRRIGATION SOLENOID VALVES

The Hunter PGV 25mm solenoid valve controls water flow to an irrigation zone using a compatible 24V AC irrigation controller. The top is secured with captive screws that stay with the cover during servicing. The flow-control handle adjusts water flow at the valve.

✓ Connections: 25mm BSP
✓ Power: 24V AC
✓ Flow Control: Adjustable water flow
✓ Flow Range: 0.7-150 L/min
✓ Operating Pressure: 150-1000 kPa

Hunter PGV 25mm Specifications
Hunter PGV 40mm & 50mm Specifications
Hunter ICV 80mm Specifications
Hunter Valves Comparison Chart

Hunter Solenoid Valve 25mm PGV Square Bolt Top with Flow Control

The Hunter PGV 25mm solenoid valve controls water flow to an irrigation zone. The flow-control handle adjusts water flow at the valve.

Its 24V AC solenoid operates with a compatible irrigation controller. Captive bonnet screws stay with the cover during servicing, helping prevent lost parts.

To open the valve manually, turn the solenoid anticlockwise 1/4 to 1/2 turn. Turn it clockwise until hand-tight to return the valve to controller operation. This releases pressure above the diaphragm through an internal passage to the outlet, without discharging water into the valve box. The external bleed screw releases water and pressure from the chamber above the diaphragm to the outside of the valve. This allows the valve to open during servicing and troubleshooting. Keep the screw closed during normal controller operation.

Hunter PGV 25mm Specifications
Hunter PGV 40mm & 50mm Specifications
Hunter ICV 80mm Specifications
Hunter Valves Comparison Chart

✓ Product Type & Application
Hunter PGV 25mm bolt top irrigation solenoid valve with flow control.

✓ Size & Connections
25mm BSP inlet and outlet.

✓ Electrical Operation
Its 24V AC solenoid operates with a compatible irrigation controller. At 50 Hz: 370 mA inrush; 210 mA holding current.

✓ Pressure & Flow
Operating pressure: 150-1000 kPa.
Flow range: 0.7-150 L/min.

✓ Flow Control & Manual Operation
Flow control: Adjusts water flow at the valve.
Manual solenoid operation: Turn anticlockwise 1/4 to 1/2 turn to open; turn clockwise until hand-tight to restore controller operation.
Internal bleed: Releases pressure above the diaphragm into the outlet pipe.
External bleed screw: Releases water and pressure outside the valve for servicing and troubleshooting. Keep closed during normal controller operation.

✓ Construction & Servicing
Double-beaded diaphragm seal. Encapsulated solenoid with captive plunger. Captive bonnet screws stay with the cover during servicing, helping prevent lost parts.

✓ Temperature
Maximum temperature: 66°C.

Video 1

Video 2

Video 3

Video 4

You may also like