Grundfos UNILIFT AP12 drainage pump without float switch
Grundfos UNILIFT AP12 drainage pump without float switch
UNILIFT AP12.50.11.3 (PUGR96001975) 50Hz manufacturer performance curve: head, efficiency and input power against flow.
UNILIFT AP12.50.11.3 (PUGR96001975) 50Hz manufacturer performance curve: head, efficiency and input power against flow.
Grundfos UNILIFT AP12 drainage pump without float switch
UNILIFT AP12.50.11.3 (PUGR96001975) 50Hz manufacturer performance curve: head, efficiency and input power against flow.

GRUNDFOS UNILIFT AP12.50.11.3 DRAINAGE PUMP 1.2KW THREE PHASE, NO FLOAT SWITCH

Grundfos UNILIFT AP12.50.11.3 suits rainwater, groundwater and suitable non-aggressive grey-water drainage. It has no float switch, allowing supervised pumping or operation through suitable external level controls. Monitor the water level because the pump has no automatic low-water stop. Performance is 120L/min at approximately 14.8m head.

✓ Performance: 120L/min at approximately 14.8m head
✓ Maximum flow: 533.4L/min
✓ Maximum head: 18m
✓ Outlet: 50mm (2") Rp / BSP female thread
✓ Maximum particle diameter: 12mm; small amounts of suspended solids
✓ Control: no float switch
✓ Motor output P2: 1.2kW; 400V three phase, no plug
✓ 10m cable; maximum installation depth 7m

Grundfos UNILIFT AP12 Official Range Catalogue
AP Installation & Operating Instructions
AP Three-Phase Control Box Instructions

Grundfos UNILIFT AP12 drainage pump without float switch

Grundfos UNILIFT AP12.50.11.3 suits rainwater, groundwater and suitable non-aggressive grey-water drainage, with a maximum flow of 533.4L/min and maximum head of 18m. These are separate limits. Actual flow depends on lift and pipe resistance; the matching 50Hz performance curve helps assess expected flow for the installation. Performance is 120L/min at approximately 14.8m head.

The outlet is 50mm (2") Rp / BSP female thread. Maximum particle diameter is 12mm. The pump suits water containing small amounts of suspended solids, but not sewage, long fibres, stones or aggressive and flammable liquids.

It has no float switch, allowing supervised pumping or operation through suitable external level controls. Monitor the water level because the pump has no automatic low-water stop.

Maximum installation depth is 7m with the 10m cable. Keep at least 3m of cable above liquid level. Install on a firm base clear of sludge and mud. Keep the inlet strainer covered during pumping and do not run dry.

This version uses a 400V three-phase, 50Hz supply and has a 10m cable without a plug. Rated motor output P2 is 1.2kW and input power P1 is 1.9kW. This no-float version needs a separately provided motor starter and motor protection matched to the nameplate current. Automatic level operation also needs a suitable level switch and controller. Electrical connection and rotation checks must follow the installation instructions.

Suitable liquid temperature is 0-55°C and pH is 4-10. The pump can operate upright or horizontally with its outlet at the highest point. For permanent installations, Grundfos recommends a union, non-return valve and isolating valve in the outlet pipe. Lift the pump by its handle.

The stainless-steel housing and semi-open stainless-steel impeller provide a compact drainage pump for portable or permanent use. A cooling jacket directs pumped liquid around the motor, supporting partly submerged operation while the inlet strainer remains covered. The removable inlet strainer gives access for cleaning.

Two-year manufacturer warranty, subject to Grundfos warranty terms and applicable consumer rights.

Grundfos UNILIFT AP12 Official Range Catalogue
AP Installation & Operating Instructions
AP Three-Phase Control Box Instructions

✓ Warranty
Two years, subject to Grundfos warranty terms and applicable consumer rights.

✓ Performance
AP12.50.11.3: 120L/min at approximately 14.8m head; maximum head 18m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.

✓ Outlet Connection
50mm (2") Rp / BSP female thread.

✓ Liquid & Solids
Maximum particle diameter: 12mm. Suitable for water containing small amounts of suspended solids.
Rainwater, groundwater and suitable non-aggressive grey water.
Liquid temperature: 0-55°C. Liquid pH: 4-10.
Not for sewage, long fibres, stones or aggressive/flammable liquids.

✓ Operation & Control
No float switch. No automatic low-water stop.

✓ Water Levels
Minimum stop level during continuous operation or external control: 110mm.
Keep the inlet strainer covered.

✓ Installation
Maximum installation depth: 7m with 10m cable.
Keep at least 3m of cable above liquid level.
Upright or horizontal operation with the outlet highest.
Stand clear of sludge and mud. Lift by the handle.
Permanent outlet pipe: union, non-return valve and isolating valve recommended.

✓ Construction
Pump housing and impeller: AISI 304 stainless steel.
Impeller: semi-open, 12mm particle passage.
Cooling jacket around the motor.
Removable inlet strainer.

✓ Motor & Electrical Supply
Supply: 400V three phase, 50Hz.
Input power P1: 1.9kW.
Rated motor output P2: 1.2kW.
Rated current: 3.2A.
No cable plug. Separately provided motor starter and motor protection required.
Cable length: 10m.
Enclosure: IP68. Insulation: Class F.

✓ Dimensions & Weight
Pump height A: 357mm.
Pump width B: 241mm.
Net weight: 16kg.

Recently viewed