Hunter ICD-600 six-station decoder with wire leads
Hunter ICD-600 six-station decoder with wire leads
Group of Hunter ICD decoders with coloured wire leads
Group of Hunter ICD decoders with coloured wire leads
Hunter ICD-600 six-station decoder with wire leads
Group of Hunter ICD decoders with coloured wire leads

HUNTER ICD-600 6 STATION DECODER ACC2 COMPATIBLE

The Hunter ICD-600 connects a shared two-wire cable to local 24VAC valve solenoids, providing 6 independently controlled watering stations in an ACC2 Decoder system. Install it near the valve or group of valves it serves.

✓ 6 Independently Controlled Stations
✓ For ACC2 Decoder & Legacy ACC-99D Systems
✓ IP68 Decoder with Integrated Surge Protection
✓ DBRY-6 Two-Wire Splice Connectors Included
✓ 5 Year Hunter Warranty

Hunter ICD Decoder Specifications
Hunter ACC2 ICD Decoder Installation
Hunter ACC2 Conventional and Decoder Specifications

Hunter ICD-600 six-station decoder with wire leads

The ICD-600 operates 6 independently controlled watering stations. It connects to the shared cable from the ACC2 Decoder controller and to local standard 24VAC irrigation valve solenoids. Each output has a colour-coded wire pair and its own programmed station number.

The ACC2 Decoder controller connects to this field wiring through an A2C-D75 output module inside the cabinet. Install the decoder near its valves so several nearby watering stations can share one decoder body.

Program the station numbers at the controller’s decoder programming port before installation. An ICD-HP handheld programmer can also read or change station numbers in the field. The decoder supports two-way communication for setup and diagnostics. Hunter also lists compatibility with legacy ACC-99D controllers.

Two-wire cable and valve leads

The shared two-wire cable can branch towards different valve locations. Join each conductor separately using suitable waterproof decoder-path splices. DBRY-6 connectors are included for the shared cable. Use suitable waterproof connectors for the separate solenoid leads.

The controller-to-decoder route can extend up to 3km on 2mm² IDWIRE1 or 4.5km on 4mm² IDWIRE2, subject to Hunter’s cable and simultaneous-load limits. Count the full route along each branch. The separate lead from the decoder to a valve solenoid has a maximum recommended length of 45m. The design guide explains how cable size and solenoids running together affect the permitted distance.

The IP68 decoder body includes surge protection and a bare earth wire. Provide earth grounding at least every 12 decoders or every 300m of two-wire cable, whichever comes first. Follow Hunter’s design guide for the grounding hardware and placement. Leave approximately 1.5m cable slack at decoder locations for service access.

5 Year Hunter Warranty.

Controller and system documents

Hunter ACC2 Decoder Owner’s Manual
Hunter ACC2 Conventional and Decoder Specifications
Hunter ICD Decoder Specifications
Hunter ACC2 Decoder Design Guide
Hunter A2C-D75 Installation Guide
Hunter ACC2 ICD Decoder Installation
Hunter ACC2 Decoder Troubleshooting Guide
Hunter ACC2 Decoder Programming Door Card
Hunter ACC2 Decoder Brochure

Centralus Wi-Fi documents

Hunter A2C-WIFI Installation Guide
Hunter Centralus System Overview

✓ Application
Field decoder for Hunter ICD two-wire irrigation systems.

✓ Warranty
5 Year Hunter Warranty.

✓ Model & Station Capacity
ICD-600 provides 6 independently controlled watering stations.
Each output has its own station number and colour-coded solenoid lead pair.

✓ Controller Compatibility
ACC2 Decoder with A2C-D75 output modules. Also compatible with legacy ACC-99D Decoder controllers.

✓ Programming & Solenoids
Station numbers programmed at the controller port or with an ICD-HP handheld programmer.
For standard 24VAC irrigation solenoids. Two-way communication supports setup and diagnostics.

✓ Cable Distances
Shared two-wire route up to 3km on 2mm² IDWIRE1 or 4.5km on 4mm² IDWIRE2, subject to cable design and simultaneous solenoid load.
Separate decoder-to-solenoid lead maximum recommended length 45m.

✓ Connectors & Grounding
DBRY-6 waterproof connectors included for the shared two-wire cable. Use suitable waterproof connectors for solenoid leads.
Provide earth grounding at least every 12 decoders or every 300m of two-wire cable, whichever comes first. Follow Hunter’s design guide for the grounding hardware and placement.
Approximately 1.5m cable slack at decoder locations.

✓ Construction & Dimensions
IP68 submersible decoder body. Integrated surge protection and earth wire.
Approximately 92mm high x 46mm wide x 38mm deep.

✓ Approvals
FCC, CE, UKCA and RCM. UL/cUL listing applies at the compatible A2C-75D system level.

Video 1

Video 2

Video 3

Video 4

Recently viewed