Lowara e-GS bore pump and motor range; representative manufacturer photograph
Lowara e-GS bore pump and motor range; representative manufacturer photograph
2GS official 50Hz flow versus head performance chart
2GS official 50Hz flow versus head performance chart
Lowara e-GS bore pump and motor range; representative manufacturer photograph
2GS official 50Hz flow versus head performance chart

2GS03 380-415V THREE PHASE BORE PUMP 0.37KW

Lowara 2GS03 is a 0.37kW multistage bore pump for irrigation, tank filling and water supply. Reference performance is 30L/min at 36m head. This version uses a 380-415V three-phase supply.

✓ Performance: 30L/min at 36m head
✓ Outlet: 32mm (1 1/4") BSP female thread
✓ Bore water; maximum sand content 150g/m3
✓ Built-in stainless-steel non-return valve
✓ Supply: 380-415V three phase
✓ Motor output: 0.37kW
✓ External starter and motor overload protection required
✓ Water temperature: up to 35°C

Lowara 2GS Official 50Hz Performance Curve
Lowara e-GS Technical Data & Installation Guidance

Lowara e-GS bore pump and motor range; representative manufacturer photograph

Lowara 2GS03 is a 0.37kW multistage bore pump for irrigation, tank filling and water supply. Reference performance is 30L/min at 36m head. This version uses a 380-415V three-phase supply.

Flow and head are paired hydraulic reference values at approximately 2900rpm, 50Hz. Actual flow depends on the pumping lift, required outlet pressure and pipe resistance. Use the matching performance curve to assess expected flow for the installation.

The outlet is 32mm (1 1/4") BSP female thread. A built-in non-return valve reduces backflow when the pump stops. These pumps handle clean bore water with up to 150g/m3 of sand.

A suitable external starter and motor overload protection are required. Motor overload protection must match the supplied motor nameplate.

For automatic tank filling or pressure operation, connect suitable level or pressure controls. Use dry-running protection where a falling water level could expose the pump. Extend the motor lead with correctly sized submersible cable and a suitable waterproof joint; secure the cable to the delivery pipe every 2-3m.

Install with the motor below the pump and keep the complete assembly submerged. While pumping, keep at least 1m of water above the pump outlet. Allow at least 3mm difference between the pump outside diameter and the bore internal diameter, with room for the cable and fittings. Position the pump clear of the bore bottom and accumulated sediment. Support it using suitable pipework and installation hardware; never lift or suspend it by its electrical cable.

Water temperature is limited to 35°C. Water must move around the outside of the motor at least 0.08m/s (8cm/s) to remove heat. Fit a cooling sleeve if the installation cannot provide that flow, including unsuitable wide-bore or tank arrangements. Keep the pump submerged and do not run it dry.

The pump casing, shaft, strainer and cable guard are stainless steel, with a cast stainless-steel discharge head and motor adapter. Floating PPO technopolymer impellers and diffusers help resist wear from sand. The pump head contains a stainless-steel non-return valve.

Suitable clean-water geothermal or fountain installations also require the correct motor cooling, submergence and controls.

One-year warranty, subject to warranty terms and applicable consumer rights.

Lowara 2GS Official 50Hz Performance Curve
Lowara e-GS Technical Data & Installation Guidance

✓ Warranty
One year, subject to warranty terms and applicable consumer rights.

✓ Performance
2GS03: 30L/min at 36m head; maximum head 47m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.
50Hz hydraulic reference at approximately 2900rpm.

✓ Outlet Connection
32mm (1 1/4") BSP female thread.
Built-in stainless-steel non-return valve.

✓ Liquid & Temperature
For clean bore water.
Maximum sand content: 150g/m3.
Water temperature: up to 35°C.
Not for sewage, fibrous waste or abrasive slurry.

✓ Starting & Motor Protection
A suitable external starter and motor overload protection are required. Motor overload protection must match the supplied motor nameplate.

For automatic tank filling or pressure operation, connect suitable level or pressure controls. Use dry-running protection where a falling water level could expose the pump.

✓ Installation & Water Levels
Keep pump and motor submerged.
While pumping, maintain at least 1m of water above the pump outlet.
Install motor below pump; keep clear of the bore bottom and sediment.
Support using suitable pipework and installation hardware; never the electrical cable.
Secure cable to pipe every 2-3m.
Installation depth must remain within the supplied motor rating.

✓ Motor Cooling
Water must move around the outside of the motor at least 0.08m/s (8cm/s) to remove heat. Fit a cooling sleeve if the installation cannot provide that flow, including unsuitable wide-bore or tank arrangements. Keep the pump submerged and do not run it dry.

✓ Construction
Stainless-steel casing, shaft, strainer and cable guard.
Cast stainless-steel discharge head and motor adapter.
Floating PPO technopolymer impellers and diffusers.
Built-in stainless-steel non-return valve; NBR valve gasket.

✓ Motor & Electrical Supply
2GS03 380-415V three phase: Motor output P2: 0.37kW; 50Hz.

Match overload protection and cable sizing to the supplied motor nameplate.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof joint.

✓ Dimensions & Clearance
Maximum pump diameter: 99mm, including cable cover.
Allow at least 3mm difference between pump diameter and bore internal diameter.
Allow clearance for electrical cable and pipe connections.