Lowara e-GS bore pump and motor range; representative manufacturer photograph
Lowara e-GS bore pump and motor range; representative manufacturer photograph
2GS official 50Hz flow versus head performance chart
2GS official 50Hz flow versus head performance chart
Lowara e-GS bore pump and motor range; representative manufacturer photograph
2GS official 50Hz flow versus head performance chart

LOWARA 2GS15 380-415V THREE PHASE BORE PUMP 1.5KW

Lowara 2GS15 is a 1.5kW multistage bore pump for irrigation, tank filling and water supply. Performance is 30L/min at 146m head. This version uses a 380-415V three-phase supply.

✓ Performance: 30L/min at 146m head
✓ Outlet: 32mm (1 1/4") BSP female thread
✓ For bore water with minimal sand or sediment
✓ Built-in stainless-steel non-return valve
✓ Supply: 380-415V three phase
✓ Motor output: 1.5kW
✓ External starter and motor overload protection required
✓ Water temperature: up to 35°C

Lowara 2GS Official 50Hz Performance Curve
Lowara e-GS Technical Data & Installation Guidance

Lowara e-GS bore pump and motor range; representative manufacturer photograph
Lowara e-GS bore pump and motor range; representative manufacturer photograph
Lowara Submersible 4" Pump - 2GS15-3 PULO2GS15-3
$2,065.72 /each
Lowara e-GS bore pump and motor range; representative manufacturer photograph
Lowara Submersible 4" Pump - 2GS22-3 PULO2GS22-3
$2,776.39 /each
Lowara e-GS bore pump and motor range; representative manufacturer photograph
Lowara Submersible 4" Pump - 2GS30-3 PULO2GS30-3
$3,219.45 /each

Lowara 2GS15 is a 1.5kW multistage bore pump for irrigation, tank filling and water supply. Performance is 30L/min at 146m head. This version uses a 380-415V three-phase supply.

Flow and head describe the same hydraulic performance point at approximately 2900rpm, 50Hz. Actual flow depends on pumping lift, required outlet pressure and pipe resistance. Use the matching performance curve to assess expected flow for the installation.

The outlet is 32mm (1 1/4") BSP female thread. A built-in non-return valve reduces backflow when the pump stops. These pumps handle clean bore water with up to 150g/m3 of sand.

A suitable external starter and motor overload protection are required. Motor overload protection must match the current on the included motor nameplate.

For automatic tank filling or pressure operation, connect suitable level or pressure controls. Use dry-running protection where a falling water level could expose the pump. Extend the motor lead with correctly sized submersible cable and a suitable waterproof joint. Secure the cable to the delivery pipe every 2-3m.

Install with the motor below the pump and keep the complete assembly submerged. While pumping, keep at least 1m of water above the pump outlet. Allow at least 3mm difference between the pump outside diameter and the bore internal diameter, with room for the cable and fittings. Position the pump clear of the bore bottom and accumulated sediment. Support it using suitable pipework and installation hardware. Never lift or suspend it by its electrical cable.

Water temperature is limited to 35°C. Water must move around the outside of the motor at least 0.08m/s (8cm/s) to remove heat. Fit a cooling sleeve if the installation cannot provide that flow, including unsuitable wide-bore or tank arrangements. Keep the pump submerged and do not run it dry.

The pump casing, shaft, strainer and cable guard are stainless steel, with a cast stainless-steel discharge head and motor adapter. Floating PPO technopolymer impellers and diffusers help resist sand wear, while the built-in stainless-steel non-return valve reduces backflow when the pump stops.

Suitable clean-water geothermal or fountain installations also require the correct motor cooling, submergence and controls.

Two-year warranty, subject to the applicable Australian Lowara supply terms and consumer rights.

Lowara 2GS Official 50Hz Performance Curve
Lowara e-GS Technical Data & Installation Guidance

✓ Warranty
Two-year warranty, subject to the applicable Australian Lowara supply terms and consumer rights.

✓ Performance
2GS15: 30L/min at 146m head. Maximum head 187m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.
50Hz hydraulic reference at approximately 2900rpm.

✓ Outlet Connection
32mm (1 1/4") BSP female thread.
Built-in stainless-steel non-return valve.

✓ Liquid & Temperature
For clean bore water.
Maximum sand content: 150g/m3.
Water temperature: up to 35°C.
Not for sewage, fibrous waste or abrasive slurry.

✓ Starting & Motor Protection
A suitable external starter and motor overload protection are required. Motor overload protection must match the current on the included motor nameplate.

✓ Automatic Operation & Installation
For automatic tank filling or pressure operation, connect suitable level or pressure controls.
Use dry-running protection where a falling water level could expose the pump.

✓ Installation & Water Levels
Keep pump and motor submerged.
While pumping, maintain at least 1m of water above the pump outlet.
Install motor below pump. Keep clear of the bore bottom and sediment.
Support using suitable pipework and installation hardware. Never suspend it by the electrical cable.
Secure cable to pipe every 2-3m.
Installation depth must remain within the included motor rating.

✓ Motor Cooling
Water must move around the outside of the motor at least 0.08m/s (8cm/s) to remove heat. Fit a cooling sleeve if the installation cannot provide that flow, including unsuitable wide-bore or tank arrangements. Keep the pump submerged and do not run it dry.

✓ Construction
Stainless-steel casing, shaft, strainer and cable guard.
Cast stainless-steel discharge head and motor adapter.
Floating PPO technopolymer impellers and diffusers.
Built-in stainless-steel non-return valve. NBR valve gasket.

✓ Motor & Electrical Supply
2GS15 380-415V three phase. Motor output P2: 1.5kW. 50Hz.
Match overload protection and cable sizing to the included motor nameplate.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof joint.

✓ Dimensions & Clearance
Maximum pump diameter: 99mm, including cable cover.
Allow at least 3mm difference between pump diameter and bore internal diameter.
Allow clearance for electrical cable and pipe connections.

Recently viewed