GRUNDFOS SP 9-23 415V THREE PHASE BORE PUMP 5.5KW

Grundfos SP 9-23 is a 5.5kW multistage bore pump for clean groundwater supply, irrigation and pressure boosting. Rated flow is 9m3/h (150L/min) at 121m head. Its stainless-steel pump and MS4000 motor form a complete set for boreholes from 105mm internal diameter.

✓ Rated flow: 9m3/h (150L/min)
✓ Rated head at that flow: 121m
✓ Outlet: 50mm (2") Rp / BSP female thread
✓ Clean water; maximum sand content 150g/m3
✓ Supply: 415V three phase
✓ Motor output: 5.5kW
✓ Starting device and thermal protection built into motor
✓ External current/motor protection required, matched to motor nameplate
✓ Minimum borehole internal diameter: 105mm; maximum submergence: 600m

SP 9 Official 50Hz Performance Curve
SP Installation & Operating Instructions

Grundfos SP 9 submersible bore pump and MS4000 motor; representative image

Grundfos SP 9-23 supplies clean groundwater for domestic water systems, irrigation and pressure boosting, with a rated flow of 9m3/h (150L/min) at 121m head. This rated duty describes flow and head together. Actual flow depends on pumping lift, required outlet pressure and pipe resistance; the matching 50Hz curve helps assess expected flow for the installation.

The outlet is 50mm (2") Rp / BSP female thread. The pump handles clean, thin, non-aggressive water with a maximum sand content of 150g/m3. A built-in non-return valve reduces return flow when the pump stops.

415V three phase. External motor protection is required to cut power if the motor overloads. Match protection settings to the current shown on the motor nameplate. Use a suitable motor-protective circuit breaker or a motor-protection unit with an electrically operated switch.

For automatic operation, connect suitable tank-level or pressure controls. Where the water level could fall below the pump inlet, use dry-running protection to stop the pump before it draws in air. Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

Keep the pump inlet submerged below the lowest water level reached while pumping. At least 0.5m of water above the inlet is recommended; greater submergence may be needed to maintain adequate pressure at the inlet. Maximum installation depth is 600m below the water surface. Install vertically with the motor below the pump and support the assembly with suitable pipework and installation hardware. Do not lift or suspend it by its electrical cable.

Liquid temperature is +2 to +40°C. Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.

This pump can run continuously without scheduled cooling stops while the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

The pump and impellers are AISI 304 stainless steel. Multiple impeller stages build head through the pump, while water-lubricated bearings support the rotating assembly.

Two-year limited manufacturer warranty, subject to Grundfos warranty terms and applicable consumer rights.

SP 9 Official 50Hz Performance Curve
SP Installation & Operating Instructions

✓ Warranty
Two-year limited manufacturer warranty, subject to Grundfos warranty terms and applicable consumer rights.

✓ Performance
SP 9-23: 150L/min at 121m head; maximum head approximately 150m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.

✓ Operating Flow Limits
For continuous running, keep pump flow between approximately 15 and 195L/min.
Motor cooling may require more than 15L/min, depending on bore diameter and installation.
Do not operate against a closed outlet for more than 30 seconds.

✓ Outlet Connection
50mm (2") Rp / BSP female thread.
Built-in non-return valve.

✓ Liquid & Sand
Clean, thin, non-aggressive water.
Maximum sand content: 150g/m3.
Liquid temperature: +2 to +40°C.

✓ Starting & Motor Protection
415V three phase. External motor protection is required to cut power if the motor overloads. Match protection settings to the current shown on the motor nameplate. Use a suitable motor-protective circuit breaker or a motor-protection unit with an electrically operated switch.

Automatic operation: connect suitable tank-level or pressure controls.
Where water levels could expose the inlet, use dry-running protection to stop the pump before it draws in air.

✓ Installation & Water Levels
Minimum borehole internal diameter: 105mm.
Maximum installation depth is 600m below the water surface.
Keep inlet below the lowest water level reached while pumping.
Keep at least 0.5m of water above the inlet as recommended; greater depth may be needed to maintain adequate inlet pressure.
Vertical installation with motor below pump.
Support with suitable pipework and installation hardware; never suspend by the electrical cable.

✓ Motor Cooling
Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.
Do not run dry.

✓ Duty
This pump can run continuously without scheduled cooling stops while the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.
Maximum starts 100 per hour and 300 per day.

✓ Construction
Pump and impellers: AISI 304 stainless steel.
Multistage hydraulic design.
Water-lubricated bearings.

✓ Motor & Electrical Supply
SP 9-23 415V three phase: Motor MS4000; P2 5.5kW; current 13.4A.
50Hz. Current ratings refer to 240V single-phase or 415V three-phase supply.
Enclosure: IP68. Insulation: Class F.
Protection settings must match the actual motor nameplate.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

✓ Dimensions & Weight
SP 9-23 415V three phase: Overall length 2065mm; maximum diameter 101mm.
Dimensions are approximate.