GRUNDFOS SP 9 SERIES 4" SUBMERSIBLE BORE PUMPS

Grundfos SP 9 multistage bore pumps supply clean groundwater for domestic water systems, irrigation and pressure boosting. Rated flow is 9m3/h (150L/min), with rated heads from 25m to 212m across the range. The stainless-steel pump sets suit boreholes from 105mm internal diameter, with single-phase two-wire, single-phase three-wire and three-phase options.

✓ Rated flow: 9m3/h (150L/min)
✓ Rated head at that flow: 25-212m, depending on model
✓ Outlet: 50mm (2") Rp / BSP female thread
✓ Clean water; maximum sand content 150g/m3
✓ Supply: 240V single phase or 415V three phase
✓ Single phase: two-wire operation or three-wire with supplied starter
✓ All three-phase and higher-power MS single-phase versions require external motor protection
✓ Minimum borehole internal diameter: 105mm

SP 9 Official 50Hz Performance Curve
SP Installation & Operating Instructions

Grundfos SP 9 submersible bore pump and MS402 motor; representative image

Grundfos SP 9 pumps supply clean groundwater for domestic water systems, irrigation and pressure boosting. Rated flow is 9m3/h (150L/min), with rated heads from 25m to 212m across these models. Each head rating is stated at that same rated flow. Actual flow depends on pumping lift, required outlet pressure and pipe resistance; the matching 50Hz curve helps assess expected flow for the installation.

The outlet is 50mm (2") Rp / BSP female thread. The pump handles clean, thin, non-aggressive water with a maximum sand content of 150g/m3. A built-in non-return valve reduces return flow when the pump stops.

240V single phase, two wire: the SP 9-5 uses a 1.1kW ULTRA RSIR motor with its starting equipment in the motor.

240V single phase, three wire: external starter included. The 1.1kW MS402 has built-in thermal protection and also requires external current protection. The 1.5kW MS402 and 2.2kW MS4000 require external motor protection in a suitable starter/control box or separately. The 3.7kW ULTRA PSC versions use a CSCR starter for the required starting torque.

415V three phase: External motor protection is required to cut power if the motor overloads. Match protection settings to the current shown on the motor nameplate. Use a suitable motor-protective circuit breaker or a motor-protection unit with an electrically operated switch.

For automatic operation, connect suitable tank-level or pressure controls. Where the water level could fall below the pump inlet, use dry-running protection to stop the pump before it draws in air. Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

Keep the pump inlet submerged below the lowest water level reached while pumping. At least 0.5m of water above the inlet is recommended; greater submergence may be needed to maintain adequate pressure at the inlet. Maximum installation depth below the water surface is 150m for MS402 and ULTRA versions, and 600m for MS4000 versions. The SP 9-11 single-phase and three-phase sets both use MS4000 motors. Install vertically with the motor below the pump and support the assembly with suitable pipework and installation hardware. Do not lift or suspend it by its electrical cable.

Liquid temperature is +2 to +40°C. Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.

The MS402 and MS4000 versions can run continuously without scheduled cooling stops while the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

The pump and impellers are AISI 304 stainless steel. Multiple impeller stages build head through the pump, while water-lubricated bearings support the rotating assembly.

Grundfos motor versions have a two-year limited manufacturer warranty. The Australian catalogue specifies a one-year motor warranty for ULTRA motors. Warranty terms and applicable consumer rights apply.

SP 9 Official 50Hz Performance Curve
SP Installation & Operating Instructions

✓ Warranty
Grundfos motor versions have a two-year limited manufacturer warranty. The Australian catalogue specifies a one-year motor warranty for ULTRA motors. Warranty terms and applicable consumer rights apply.

✓ Performance
SP 9-5: 150L/min at 25m head; maximum head approximately 30m.
SP 9-8: 150L/min at 41m head; maximum head approximately 50m.
SP 9-11: 150L/min at 57m head; maximum head approximately 70m.
SP 9-13: 150L/min at 68m head; maximum head approximately 85m.
SP 9-16: 150L/min at 84m head; maximum head approximately 105m.
SP 9-18: 150L/min at 94m head; maximum head approximately 115m.
SP 9-21: 150L/min at 110m head; maximum head approximately 135m.
SP 9-23: 150L/min at 121m head; maximum head approximately 150m.
SP 9-25: 150L/min at 132m head; maximum head approximately 160m.
SP 9-29: 150L/min at 153m head; maximum head approximately 185m.
SP 9-32: 150L/min at 169m head; maximum head approximately 205m.
SP 9-36: 150L/min at 190m head; maximum head approximately 230m.
SP 9-40: 150L/min at 212m head; maximum head approximately 255m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.

✓ Operating Flow Limits
For continuous running, keep pump flow between approximately 15 and 195L/min.
Motor cooling may require more than 15L/min, depending on bore diameter and installation.
Do not operate against a closed outlet for more than 30 seconds.

✓ Outlet Connection
50mm (2") Rp / BSP female thread.
Built-in non-return valve.

✓ Liquid & Sand
Clean, thin, non-aggressive water.
Maximum sand content: 150g/m3.
Liquid temperature: +2 to +40°C.

✓ Starting & Motor Protection
240V single phase, two wire: the SP 9-5 uses a 1.1kW ULTRA RSIR motor with its starting equipment in the motor.

240V single phase, three wire: external starter included. The 1.1kW MS402 has built-in thermal protection and also requires external current protection. The 1.5kW MS402 and 2.2kW MS4000 require external motor protection in a suitable starter/control box or separately. The 3.7kW ULTRA PSC versions use a CSCR starter for the required starting torque.

415V three phase: External motor protection is required to cut power if the motor overloads. Match protection settings to the current shown on the motor nameplate. Use a suitable motor-protective circuit breaker or a motor-protection unit with an electrically operated switch.

✓ Automatic Operation & Installation
Automatic operation: connect suitable tank-level or pressure controls.
Where water levels could expose the inlet, use dry-running protection to stop the pump before it draws in air.

✓ Installation & Water Levels
Minimum borehole internal diameter: 105mm.
Maximum installation depth below the water surface is 150m for MS402 and ULTRA versions, and 600m for MS4000 versions. The SP 9-11 single-phase and three-phase sets both use MS4000 motors.
Keep inlet below the lowest water level reached while pumping.
Keep at least 0.5m of water above the inlet as recommended; greater depth may be needed to maintain adequate inlet pressure.
Vertical installation with motor below pump.
Support with suitable pipework and installation hardware; never suspend by the electrical cable.

✓ Motor Cooling
Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.
Do not run dry.

✓ Duty
The MS402 and MS4000 versions can run continuously without scheduled cooling stops while the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.
MS402 and MS4000 versions: maximum starts 100 per hour and 300 per day.

✓ Construction
Pump and impellers: AISI 304 stainless steel.
Multistage hydraulic design.
Water-lubricated bearings.

✓ Motor & Electrical Supply
SP 9-5 240V three wire: Motor MS402; P2 1.1kW; current 7.1A. Motor lead 1.7m.
SP 9-5 240V two wire ULTRA: Motor ULTRA / RSIR; P2 1.1kW; current 7.1A.
SP 9-5 415V three phase: Motor MS402; P2 1.1kW; current 3.6A.
SP 9-8 240V three wire: Motor MS402; P2 1.5kW; current 9.8A. Motor lead 1.7m.
SP 9-8 415V three phase: Motor MS402; P2 1.5kW; current 4.4A.
SP 9-11 240V three wire: Motor MS4000; P2 2.2kW; current 15.6A.
SP 9-11 415V three phase: Motor MS4000; P2 2.2kW; current 6.3A.
SP 9-13 240V three wire ULTRA: Motor ULTRA / PSC; P2 3.7kW; current 25A.
SP 9-13 415V three phase: Motor MS4000; P2 3kW; current 8.1A.
SP 9-16 240V three wire ULTRA: Motor ULTRA / PSC; P2 3.7kW; current 25A.
SP 9-16 415V three phase: Motor MS4000; P2 3kW; current 8.1A.
SP 9-18 240V three wire ULTRA: Motor ULTRA / PSC; P2 3.7kW; current 25A.
SP 9-18 415V three phase: Motor MS4000; P2 4kW; current 9.8A.
SP 9-21 415V three phase: Motor MS4000; P2 4kW; current 9.8A.
SP 9-23 415V three phase: Motor MS4000; P2 5.5kW; current 13.4A.
SP 9-25 415V three phase: Motor MS4000; P2 5.5kW; current 13.4A.
SP 9-29 415V three phase: Motor MS4000; P2 5.5kW; current 13.4A.
SP 9-32 415V three phase: Motor MS4000; P2 7.5kW; current 19.6A.
SP 9-36 415V three phase: Motor MS4000; P2 7.5kW; current 19.6A.
SP 9-40 415V three phase: Motor MS4000; P2 7.5kW; current 19.6A.

✓ Motor & Electrical Notes
50Hz. Current ratings refer to 240V single-phase or 415V three-phase supply.
MS402: IP68, Class B insulation. MS4000: IP68, Class F insulation.
Protection settings must match the actual motor nameplate.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

✓ Dimensions & Weight
SP 9-5 240V three wire: Overall length 837mm; maximum diameter 101mm; net weight 17.7kg.
SP 9-5 415V three phase: Overall length 797mm; maximum diameter 101mm.
SP 9-8 240V three wire: Overall length 987mm; maximum diameter 101mm; net weight 20kg.
SP 9-8 415V three phase: Overall length 987mm; maximum diameter 101mm.
SP 9-13 415V three phase: Overall length 1385mm; maximum diameter 101mm.
SP 9-16 415V three phase: Overall length 1535mm; maximum diameter 101mm.
SP 9-18 415V three phase: Overall length 1715mm; maximum diameter 101mm.
SP 9-21 415V three phase: Overall length 1865mm; maximum diameter 101mm.
SP 9-23 415V three phase: Overall length 2065mm; maximum diameter 101mm.
SP 9-25 415V three phase: Overall length 2165mm; maximum diameter 101mm.
SP 9-29 415V three phase: Overall length 2365mm; maximum diameter 101mm.
SP 9-32 415V three phase: Overall length 2615mm; maximum diameter 101mm.
SP 9-36 415V three phase: Overall length 2815mm; maximum diameter 101mm.
SP 9-40 415V three phase: Overall length 3015mm; maximum diameter 101mm.

✓ Dimension Notes
Dimensions are approximate.