Grundfos SP series submersible bore pump; representative image
Grundfos SP series submersible bore pump; representative image
Grundfos SP 5A official 50Hz performance chart showing flow against head in metres and pressure in kPa
Grundfos SP 5A official 50Hz performance chart showing flow against head in metres and pressure in kPa
Grundfos SP series submersible bore pump; representative image
Grundfos SP 5A official 50Hz performance chart showing flow against head in metres and pressure in kPa

GRUNDFOS SP 5A SERIES 4" SUBMERSIBLE BORE PUMPS

Grundfos SP 5A multistage bore pumps supply clean groundwater for domestic water systems, irrigation and pressure boosting. Rated flow is 5m3/h (83.3L/min), with rated heads from 16m to 180m across the range. The stainless-steel pump sets suit boreholes from 105mm internal diameter, with single-phase two-wire, single-phase three-wire and three-phase options.

✓ Rated flow: 5m3/h (83.3L/min)
✓ Rated head at that flow: 16-180m, depending on model
✓ Outlet: 40mm (1 1/2") Rp / BSP female thread
✓ Clean water; maximum sand content 50g/m3
✓ Supply: 240V single phase or 415V three phase
✓ Single phase: two-wire operation or three-wire with supplied starter
✓ External motor protection required on all three-phase and higher-power MS single-phase versions
✓ Minimum borehole internal diameter: 105mm

SP 5A Official 50Hz Performance Curve
SP Installation & Operating Instructions

Grundfos SP series submersible bore pump; representative image

Grundfos SP 5A pumps supply clean groundwater for domestic water systems, irrigation and pressure boosting. Rated flow is 5m3/h (83.3L/min), with rated heads from 16m to 180m across these models. Each head rating is stated at that same rated flow. Actual flow depends on pumping lift, required outlet pressure and pipe resistance; the matching 50Hz curve helps assess expected flow for the installation.

The outlet is 40mm (1 1/2") Rp / BSP female thread. The pump handles clean, thin, non-aggressive water with a maximum sand content of 50g/m3. A built-in non-return valve reduces return flow when the pump stops.

The 240V single-phase two-wire versions use MS402 motors at 0.37-0.75kW and an ULTRA RSIR motor at 1.1kW. Two-wire versions have their starting equipment in the motor. The 240V single-phase three-wire packages include the external starter for their motor.

MS402 single-phase motors at 0.37-0.75kW have built-in thermal protection that cuts power if the motor overheats. The 1.1kW single-phase MS402 motor also requires external current protection. The 1.5kW single-phase MS402 and 2.2kW single-phase MS4000 motors require external motor protection in a suitable starter/control box or as a separate device. All 415V three-phase versions require a motor-protection device that cuts power if the motor overloads. Match protection settings to the motor nameplate.

For automatic operation, connect suitable tank-level or pressure controls. Where the water level could fall below the pump inlet, use dry-running protection to stop the pump before it draws in air. Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

Keep the pump inlet submerged below the lowest water level reached while pumping. At least 0.5m of water above the inlet is recommended; greater submergence may be needed to maintain adequate pressure at the inlet. Maximum installation depth below the water surface is 150m for MS402 and ULTRA versions, and 600m for MS4000 versions. Install vertically with the motor below the pump and support the assembly with suitable pipework and installation hardware. Do not lift or suspend it by its electrical cable.

Liquid temperature is +2 to +40°C. Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.

The MS402 and MS4000 versions can run continuously without scheduled cooling stops while the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

The pump and impellers are AISI 304 stainless steel. Multiple impeller stages build head through the pump, while water-lubricated bearings support the rotating assembly. MS402 motors have IP68 protection and Class B insulation; MS4000 motors have IP68 protection and Class F insulation.

Grundfos motor versions have a two-year limited manufacturer warranty. The Australian catalogue specifies a one-year motor warranty for ULTRA motors. Warranty terms and applicable consumer rights apply.

SP 5A Official 50Hz Performance Curve
SP Installation & Operating Instructions

✓ Warranty
Grundfos motor versions have a two-year limited manufacturer warranty. The Australian catalogue specifies a one-year motor warranty for ULTRA motors. Warranty terms and applicable consumer rights apply.

✓ Performance
SP 5A-4: 83.3L/min at 16m head; maximum head approximately 25m.
SP 5A-6: 83.3L/min at 25m head; maximum head approximately 40m.
SP 5A-8: 83.3L/min at 33m head; maximum head approximately 50m.
SP 5A-12: 83.3L/min at 49m head; maximum head approximately 75m.
SP 5A-17: 83.3L/min at 70m head; maximum head approximately 110m.
SP 5A-21: 83.3L/min at 86m head; maximum head approximately 135m.
SP 5A-25: 83.3L/min at 102m head; maximum head approximately 160m.
SP 5A-33: 83.3L/min at 135m head; maximum head approximately 210m.
SP 5A-38: 83.3L/min at 155m head; maximum head approximately 245m.
SP 5A-44: 83.3L/min at 180m head; maximum head approximately 280m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.

✓ Operating Flow Limits
For continuous running, keep pump flow between approximately 8.3 and 108.3L/min.
Motor cooling may require more than 8.3L/min, depending on bore diameter and installation.
Do not operate against a closed outlet for more than 30 seconds.

✓ Outlet Connection
40mm (1 1/2") Rp / BSP female thread.
Built-in non-return valve.

✓ Liquid & Sand
Clean, thin, non-aggressive water.
Maximum sand content: 50g/m3.
Liquid temperature: +2 to +40°C.

✓ Starting & Motor Protection
240V single phase, two wire:
0.37-0.75kW: MS402 motor with built-in starting device and thermal protection.
1.1kW: ULTRA RSIR motor.
Two supply conductors plus protective earth.

240V single phase, three wire:
Starter included with the package.
0.37-0.75kW: built-in thermal protection.
1.1kW MS402: built-in thermal protection plus required external current protection.
1.5kW MS402 and 2.2kW MS4000: external motor protection required in a suitable starter/control box or separately.
Three motor conductors plus protective earth.

415V three phase:
External motor-protection device required to cut power if the motor overloads.
Use a suitable motor-protective circuit breaker or motor-protection unit with an electrically operated switch.
Match protection settings to the current shown on the motor nameplate.

✓ Automatic Operation & Installation
Automatic operation: connect suitable tank-level or pressure controls.
Where water levels could expose the inlet, use dry-running protection to stop the pump before it draws in air.

✓ Installation & Water Levels
Minimum borehole internal diameter: 105mm.
MS402 and ULTRA versions: maximum submergence 150m.
MS4000 versions: maximum submergence 600m.
Submergence is measured below the water surface.
Keep inlet below the lowest water level reached while pumping.
Keep at least 0.5m of water above the inlet as recommended; greater depth may be needed to maintain adequate inlet pressure.
Vertical installation with motor below pump.
Support with suitable pipework and installation hardware; never suspend by the electrical cable.

✓ Motor Cooling
Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.
MS402 and MS4000 versions: maximum starts 100 per hour and 300 per day.
Do not run dry.

✓ Duty
The MS402 and MS4000 versions can run continuously without scheduled cooling stops while the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

✓ Construction
Pump and impellers: AISI 304 stainless steel.
Multistage hydraulic design.
Water-lubricated bearings.

✓ Motor & Electrical Supply
SP 5A-4 240V three wire: Motor MS402; P2 0.37kW; current 3.8A. Motor lead 1.7m.
SP 5A-4 240V two wire: Motor MS402; P2 0.37kW; current 3.8A. Motor lead 1.7m.
SP 5A-4 415V three phase: Motor MS402; P2 0.37kW; current 1.5A. Motor lead 1.7m.
SP 5A-6 240V three wire: Motor MS402; P2 0.55kW; current 5.5A. Motor lead 1.7m.
SP 5A-6 240V two wire: Motor MS402; P2 0.55kW; current 5.5A. Motor lead 1.7m.
SP 5A-6 415V three phase: Motor MS402; P2 0.55kW; current 2.4A. Motor lead 1.7m.
SP 5A-8 240V three wire: Motor MS402; P2 0.75kW; current 7A. Motor lead 1.7m.
SP 5A-8 240V two wire: Motor MS402; P2 0.75kW; current 7A. Motor lead 1.7m.
SP 5A-8 415V three phase: Motor MS402; P2 0.75kW; current 2.4A. Motor lead 1.7m.
SP 5A-12 240V three wire: Motor MS402; P2 1.1kW; current 7.1A. Motor lead 1.7m.
SP 5A-12 240V two wire ULTRA: Motor ULTRA / RSIR; P2 1.1kW; current 9.6A.
SP 5A-12 415V three phase: Motor MS402; P2 1.1kW; current 3.6A. Motor lead 1.7m.
SP 5A-17 240V three wire: Motor MS402; P2 1.5kW; current 9.8A. Motor lead 1.7m.
SP 5A-17 415V three phase: Motor MS402; P2 1.5kW; current 4.4A. Motor lead 1.7m.
SP 5A-21 240V three wire: Motor MS4000; P2 2.2kW; current 15.6A. Motor lead 1.7m.
SP 5A-21 415V three phase: Motor MS4000; P2 2.2kW; current 6.3A. Motor lead 1.7m.
SP 5A-25 240V three wire: Motor MS4000; P2 2.2kW; current 15.6A.
SP 5A-25 415V three phase: Motor MS4000; P2 2.2kW; current 6.3A.
SP 5A-33 415V three phase: Motor MS4000; P2 3kW; current 8.1A.
SP 5A-38 415V three phase: Motor MS4000; P2 4kW; current 9.8A.
SP 5A-44 415V three phase: Motor MS4000; P2 4kW; current 9.8A.

✓ Motor & Electrical Notes
50Hz. Current ratings refer to 240V single-phase or 415V three-phase supply.
MS402: IP68, Class B insulation. MS4000: IP68, Class F insulation.
Protection settings must match the actual motor nameplate.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

✓ Dimensions & Weight
SP 5A-4 240V three wire: Overall length 496.2mm; maximum diameter 101mm; net weight 10.2kg.
SP 5A-4 240V two wire: Overall length 496.2mm; maximum diameter 101mm; net weight 9.5kg.
SP 5A-4 415V three phase: Overall length 466.2mm; maximum diameter 101mm; net weight 8.9kg.
SP 5A-6 240V three wire: Overall length 558.2mm; maximum diameter 101mm; net weight 11.6kg.
SP 5A-6 240V two wire: Overall length 558.2mm; maximum diameter 101mm; net weight 10.9kg.
SP 5A-6 415V three phase: Overall length 523.2mm; maximum diameter 101mm; net weight 10.2kg.
SP 5A-8 240V three wire: Overall length 630.2mm; maximum diameter 101mm; net weight 13.2kg.
SP 5A-8 240V two wire: Overall length 630.2mm; maximum diameter 101mm; net weight 12.5kg.
SP 5A-8 415V three phase: Overall length 600.2mm; maximum diameter 101mm; net weight 12kg.
SP 5A-12 240V three wire: Overall length 754.2mm; maximum diameter 101mm; net weight 15.7kg.
SP 5A-12 415V three phase: Overall length 714.2mm; maximum diameter 101mm; net weight 14.1kg.
SP 5A-17 240V three wire: Overall length 859.2mm; maximum diameter 101mm; net weight 17.4kg.
SP 5A-17 415V three phase: Overall length 859.2mm; maximum diameter 101mm; net weight 16.9kg.
SP 5A-21 240V three wire: Overall length 1313.2mm; maximum diameter 101mm; net weight 40kg.
SP 5A-21 415V three phase: Overall length 1051.2mm; maximum diameter 101mm; net weight 22.8kg.
SP 5A-25 240V three wire: Overall length 1355.2mm; maximum diameter 101mm.
SP 5A-25 415V three phase: Overall length 1135.2mm; maximum diameter 101mm.
SP 5A-33 415V three phase: Overall length 1343.2mm; maximum diameter 101mm.
SP 5A-38 415V three phase: Overall length 1570.2mm; maximum diameter 101mm.
SP 5A-44 415V three phase: Overall length 1696.2mm; maximum diameter 101mm.

✓ Dimension Notes
Dimensions are approximate.

Recently viewed