GRUNDFOS SP 5A-12 BORE PUMP 1.1KW 415V THREE PHASE

Grundfos SP 5A-12 is a 1.1kW multistage bore pump for clean groundwater supply, irrigation and pressure boosting. Rated flow is 5m3/h (83.3L/min) at 49m head. Its stainless-steel pump and MS402 motor form a complete set for boreholes from 105mm internal diameter.

✓ Rated flow: 5m3/h (83.3L/min)
✓ Rated head at that flow: 49m
✓ Outlet: 40mm (1 1/2") Rp / BSP female thread
✓ Clean water; maximum sand content 50g/m3
✓ Supply: 415V three phase
✓ Motor output: 1.1kW
✓ External motor protection required
✓ Minimum borehole internal diameter: 105mm; maximum submergence: 150m

SP 5A Official 50Hz Performance Curve
SP Installation & Operating Instructions

Grundfos SP series submersible bore pump; representative image

Grundfos SP 5A-12 supplies clean groundwater for domestic water systems, irrigation and pressure boosting, with a rated flow of 5m3/h (83.3L/min) at 49m head. This rated duty describes flow and head together. Actual flow depends on pumping lift, required outlet pressure and pipe resistance; the matching 50Hz curve helps assess expected flow for the installation.

The outlet is 40mm (1 1/2") Rp / BSP female thread. The pump handles clean, thin, non-aggressive water with a maximum sand content of 50g/m3. A built-in non-return valve reduces return flow when the pump stops.

The 1.1kW MS402 motor uses a 415V three-phase, 50Hz supply. It requires a motor-protection device that cuts power if the motor overloads. Use a suitable motor-protective circuit breaker or a motor-protection unit with an electrically operated switch. Match settings to the current shown on the motor nameplate.

For automatic operation, connect suitable tank-level or pressure controls. Where the water level could fall below the pump inlet, use dry-running protection to stop the pump before it draws in air. Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

Keep the pump inlet submerged below the lowest water level reached while pumping. At least 0.5m of water above the inlet is recommended; greater submergence may be needed to maintain adequate pressure at the inlet. Maximum installation depth is 150m below the water surface. Install vertically with the motor below the pump and support the assembly with suitable pipework and installation hardware. Do not lift or suspend it by its electrical cable.

Liquid temperature is +2 to +40°C. Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.

This pump can run continuously without scheduled cooling stops while the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

The pump and impellers are AISI 304 stainless steel. Multiple impeller stages build head through the pump, while water-lubricated bearings support the rotating assembly. The Grundfos MS402 motor is rated IP68 with Class B insulation.

Two-year limited manufacturer warranty, subject to Grundfos warranty terms and applicable consumer rights.

SP 5A Official 50Hz Performance Curve
SP Installation & Operating Instructions

✓ Warranty
Two-year limited manufacturer warranty, subject to Grundfos warranty terms and applicable consumer rights.

✓ Performance
SP 5A-12: 83.3L/min at 49m head; maximum head approximately 75m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.

✓ Operating Flow Limits
For continuous running, keep pump flow between approximately 8.3 and 108.3L/min.
Motor cooling may require more than 8.3L/min, depending on bore diameter and installation.
Do not operate against a closed outlet for more than 30 seconds.

✓ Outlet Connection
40mm (1 1/2") Rp / BSP female thread.
Built-in non-return valve.

✓ Liquid & Sand
Clean, thin, non-aggressive water.
Maximum sand content: 50g/m3.
Liquid temperature: +2 to +40°C.

✓ Starting & Motor Protection
415V three phase.
External motor-protection device required to cut power if the motor overloads.
Use a suitable motor-protective circuit breaker or motor-protection unit with an electrically operated switch.
Match settings to the current shown on the motor nameplate.

Automatic operation: connect suitable tank-level or pressure controls.
Where water levels could expose the inlet, use dry-running protection to stop the pump before it draws in air.

✓ Installation & Water Levels
Minimum borehole internal diameter: 105mm.
Maximum installation depth: 150m below the water surface.
Keep inlet below the lowest water level reached while pumping.
Keep at least 0.5m of water above the inlet as recommended; greater depth may be needed to maintain adequate inlet pressure.
Vertical installation with motor below pump.
Support with suitable pipework and installation hardware; never suspend by the electrical cable.

✓ Motor Cooling
Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.
maximum starts 100 per hour and 300 per day.
Do not run dry.

✓ Duty
This pump can run continuously without scheduled cooling stops while the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

✓ Construction
Pump and impellers: AISI 304 stainless steel.
Multistage hydraulic design.
Water-lubricated bearings.

✓ Motor & Electrical Supply
SP 5A-12 415V three phase: Motor MS402; P2 1.1kW; current 3.6A. Motor lead 1.7m.
50Hz. Current ratings refer to 240V single-phase or 415V three-phase supply.
Enclosure: IP68. Insulation: Class B.
Protection settings must match the actual motor nameplate.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

✓ Dimensions & Weight
SP 5A-12 415V three phase: Overall length 714.2mm; maximum diameter 101mm; net weight 14.1kg.
Dimensions are approximate.