MULTICORE IRRIGATION CABLE 1.0MM² IN OUTER SHEATH

Multicore 1.0mm² irrigation cable in outer sheath for extra low voltage controller-to-solenoid valve wiring. Select by core count and roll length to suit the irrigation system layout.

✓ 1.0mm² Conductor Size
✓ 2, 3, 5, 7, 9 & 13 Core Options
✓ 100m & 500m Roll Options
✓ Direct Burial Suitable
✓ 30V Extra Low Voltage Rated
✓ For Irrigation Controllers and Solenoid Valves

Multicore Irrigation Cable Specifications

Cable Multicore (3 Core) 1.0 mm in Outer Sheath, 100 Metre

Multicore 1.0mm² irrigation cable in outer sheath is extra low voltage direct burial cable used to connect irrigation controller outputs to solenoid valves. It is suitable for irrigation control wiring where multiple valve stations need to be run through one outer-sheathed cable.

This range includes selected 2 core, 3 core, 5 core, 7 core, 9 core and 13 core options in 100m and 500m rolls. Select the core count to suit the number of valve stations, allowing for a common wire and any spare cores required for future valve additions. Use suitable waterproof wire connectors for buried, valve box or exposed irrigation cable joins.

Multicore Irrigation Cable Specifications

✓ Product Type & Size
Multicore 1.0mm² irrigation cable in outer sheath, available in selected 2 core, 3 core, 5 core, 7 core, 9 core and 13 core options.

✓ Application
Extra low voltage irrigation valve cable for connecting nominal 24V irrigation controller outputs to solenoid valves.

✓ Voltage Rating
30V rated cable.

✓ Installation
Suitable for direct burial irrigation applications.

✓ Conductor
Class 2 plain copper conductor to AS1125. 1.0mm² conductors use 7/0.43 strand construction.

✓ Electrical Data
Maximum D.C. resistance at 20°C is 21.2mΩ/m.

✓ Core Insulation
PP UV stabilised colour-coded core insulation, nominal 0.45mm insulation thickness.

✓ Outer Sheath
PVC 5V90 UV stabilised blue sheath to AS/NZS 3808:2000 with nylon rip cord.

✓ Core Colours
Colour-coded conductors for easier valve station identification. Core colours vary by core count.

✓ Joining Note
Use suitable waterproof wire connectors for buried, valve box or exposed irrigation cable joins. Poor cable joints can cause corrosion, voltage loss and premature system failure.

✓ Safety Note
Extra low voltage irrigation cable only. Not suitable for mains power connection.