WATER METER TANGENTIAL PADDLE 200MM FLANGED TABLE E 100L PULSE

Tangential Paddle 200mm flanged Table E water meter with 100L pulse output for irrigation, agricultural and loaded-water measurement applications.

✓ 200mm Flanged Water Meter
✓ Table E Flanged Connection
✓ 100L Pulse Output
✓ PN16 Pressure Rating
✓ 50°C Maximum Temperature
✓ Check Flow Range Before Ordering

Zenner Threaded Water Meter Specifications

Zenner Flanged Water Meter Specifications

Zenner Water Meter Installation Guide

Water Meter Tangential Paddle 200mm Flanged Table E - 100L Pulse is a mechanical flanged water meter used for agricultural, irrigation and loaded-water measurement applications. It is suitable where a 200mm flanged meter with pulse output is required and the flow range suits the system.

This 200mm model is supplied with Table E flanged connection and 100L pulse output. Confirm flange compatibility, expected flow range, installation position and pulse equipment compatibility before ordering.

Zenner Threaded Water Meter Specifications

Zenner Flanged Water Meter Specifications

Zenner Water Meter Installation Guide

✓ Product Type & Size
Tangential paddle flanged water meter, 200mm.

✓ Connection
Table E flanged connection.

✓ Application
Suitable for agricultural, irrigation and loaded-water measurement applications where the meter size, flow range and installation requirements suit the system.

✓ Pulse Output
100L pulse output version for remote readout where compatible equipment is used.

✓ Pressure Rating
PN16.

✓ Maximum Temperature
50°C.

✓ Flow Performance
Nominal flow: 450 m³/h.
Maximum flow, short-term: 900 m³/h.
Maximum flow, constant: 800 m³/h.
Transitional flow: 80 m³/h.
Minimum flow: 32 m³/h.

✓ Measuring Accuracy
Class A.

✓ Dimensions
Overall length: 350mm.
Height H1: 335mm.
Height H2: 180mm.
Flange diameter: 340mm.
Bolt circle diameter: 295mm.
Number of bolts: 12.
Bolt diameter: 23mm.
Approximate weight: 43.5kg.

✓ Installation Note
Install in accordance with supplier installation requirements and relevant site requirements. Confirm flow direction, installation position, straight-pipe requirements and pulse compatibility before ordering.