GRUNDFOS PM2 ELECTRONIC PUMP CONTROLLER

The Grundfos PM2 automatically starts a water-supply pump when pressure falls, keeps it running while water is being used, and stops it when the flow ends. Its start pressure is adjustable from 150 to 500 kPa, so the setting can be matched to the system. The front display shows water pressure. Dry-run protection helps protect the pump from running without water, and the cycling alarm can stop repeated starts caused by a small leak.

✓ Adjustable start pressure: 150–500 kPa in 50 kPa steps
✓ Inlet: 1" BSP male thread
✓ Outlet: 1" BSP male thread
✓ Maximum operating pressure: 1000 kPa

Grundfos PM2 Specifications

Grundfos PM2 Installation & Operating Instructions

Grundfos PM2 electronic pump controller showing pressure display and threaded water connections; cables not shown

The Grundfos PM2 automatically starts a water-supply pump when pressure falls, keeps it running while water is being used, and stops it when the flow ends. Its start pressure is adjustable from 150 to 500 kPa, so the setting can be matched to the system. The front display shows water pressure. Dry-run protection helps protect the pump from running without water, and the cycling alarm can stop repeated starts caused by a small leak.

Suitable applications include clean-water household supply, rainwater systems, irrigation and pressure boosting. Use clean, thin, non-aggressive and non-explosive liquids without solid particles or fibres.

Inlet: 1" BSP male thread.
Outlet: 1" BSP male thread; the outlet connection rotates to suit the pipework.

Maximum operating pressure is 1000 kPa. Match the pump’s pressure capability and the height of the highest outlet to the controller’s start setting.

Start pressure can be set from 150 to 500 kPa in 50 kPa steps. In normal water-demand mode, the pump continues to run while flow is detected and stops after flow falls below approximately 1LPM, with a 10-second delay. The selected start pressure is not a constant delivery-pressure setting.

With a suitably sized external pressure tank, PM2 can instead be set to stop the pump when pressure rises to 100 kPa above the chosen start pressure. In this mode, pressure determines both starting and stopping. The internal 0.1L tank is too small to replace the external tank required for this setting.

Dry-run protection stops the pump if the controller detects neither pressure nor flow during priming or normal operation. Optional auto reset can retry after dry-running or cycling alarms. A selectable 30-minute maximum continuous-running function can stop the pump if water demand continues unexpectedly; leave this disabled where longer legitimate runs are required.

A built-in non-return valve helps retain system pressure. The outlet rotates to suit the pipework. The front panel displays system pressure as well as running and alarm status.

The controller uses a 220–240V single-phase, 50/60Hz supply and has an IP65 enclosure.

Install downstream of the pump and upstream of the first outlet, with the operating panel visible. Keep cable entries from pointing upward, protect against freezing and prime the pump before operation. Match the pump, control setting and system pressure before starting.

Two-year Grundfos consumer warranty, subject to its terms.

Grundfos PM2 Specifications
Grundfos PM2 Installation & Operating Instructions

✓ Application
Automatic start/stop control for clean-water supply, rainwater systems, irrigation and pressure boosting.
Clean, thin, non-aggressive liquids without solids or fibres.

✓ Warranty
Two-year Grundfos consumer warranty, subject to its terms.

✓ Model Specifications
PM2
Adjustable start pressure: 150–500 kPa in 50 kPa steps.
Maximum operating pressure: 1000 kPa.

✓ Inlet & Outlet Connections
Inlet: 1" BSP male thread.
Outlet: 1" BSP male thread; rotating connection.

✓ Automatic Operation
Normal mode: starts when pressure falls to the selected start setting.
Keeps running while water is being used.
Stops when flow falls below approximately 1LPM, with a 10-second delay.
External-tank mode: pressure determines both starting and stopping.
Stop pressure in external-tank mode: 100 kPa above the selected start pressure.
A suitably sized external tank is required; internal tank volume is only 0.1L.

✓ Pump Protection
Dry-run shutdown if the controller detects neither pressure nor flow; detection time depends on priming or normal operation.
Cycling alarm can stop repeated starts caused by small leaks.
Selectable automatic reset after dry-running or cycling alarms.
Selectable maximum continuous operating time: 30 minutes.

✓ Construction
Built-in non-return valve.
Rotating outlet connection.
Front power, running and alarm indicators.
Pressure indication and adjustable control settings.

✓ Electrical Supply
220–240V single phase, 50/60Hz.
Enclosure class: IP65.
Maximum inductive contact load: 10A.

✓ Installation
Install after the pump and before the first outlet.
Keep the operating panel visible and cable entries from pointing upwards.
Prime the pump before operation and protect the installation from freezing.
Match pump head, start pressure and outlet height using the installation instructions.