Grundfos SP 7 submersible bore pump and MS402 motor; representative image
Grundfos SP 7 submersible bore pump and MS402 motor; representative image
Grundfos SP 7 official 50Hz performance chart showing flow against head in metres and pressure in kPa
Grundfos SP 7 official 50Hz performance chart showing flow against head in metres and pressure in kPa
Grundfos SP 7 submersible bore pump and MS402 motor; representative image
Grundfos SP 7 official 50Hz performance chart showing flow against head in metres and pressure in kPa

GRUNDFOS SP 7-8 240V TWO WIRE ULTRA BORE PUMP 1.1KW

Grundfos SP 7-8 is a 1.1kW multistage bore pump for clean groundwater supply, irrigation and pressure boosting. Rated flow is 7m3/h (116.7L/min) at 36m head. Its stainless-steel pump and ULTRA / RSIR motor form a complete set for boreholes from 105mm internal diameter.

✓ Rated flow: 7m3/h (116.7L/min)
✓ Rated head at that flow: 36m
✓ Outlet: 40mm (1 1/2") Rp / BSP female thread
✓ Clean water; maximum sand content 150g/m3
✓ Supply: 240V two wire
✓ Motor output: 1.1kW
✓ Minimum borehole internal diameter: 105mm; maximum submergence: 150m

SP 7 Official 50Hz Performance Curve
SP Installation & Operating Instructions

Grundfos SP 7 submersible bore pump and MS402 motor; representative image

Grundfos SP 7-8 supplies clean groundwater for domestic water systems, irrigation and pressure boosting, with a rated flow of 7m3/h (116.7L/min) at 36m head. This rated duty describes flow and head together. Actual flow depends on pumping lift, required outlet pressure and pipe resistance; the matching 50Hz curve helps assess expected flow for the installation.

The outlet is 40mm (1 1/2") Rp / BSP female thread. The pump handles clean, thin, non-aggressive water with a maximum sand content of 150g/m3. A built-in non-return valve reduces return flow when the pump stops.

240V single phase, two wire. This version uses a 1.1kW ULTRA RSIR motor with its starting equipment in the motor.

For automatic operation, connect suitable tank-level or pressure controls. Where the water level could fall below the pump inlet, use dry-running protection to stop the pump before it draws in air. Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

Keep the pump inlet submerged below the lowest water level reached while pumping. At least 0.5m of water above the inlet is recommended; greater submergence may be needed to maintain adequate pressure at the inlet. Maximum installation depth is 150m below the water surface. Install vertically with the motor below the pump and support the assembly with suitable pipework and installation hardware. Do not lift or suspend it by its electrical cable.

Liquid temperature is +2 to +40°C. Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.

The pump and impellers are AISI 304 stainless steel. Multiple impeller stages build head through the pump, while water-lubricated bearings support the rotating assembly.

The Australian catalogue specifies a one-year ULTRA motor warranty, subject to its terms and applicable consumer rights.

SP 7 Official 50Hz Performance Curve
SP Installation & Operating Instructions

✓ Warranty
The Australian catalogue specifies a one-year ULTRA motor warranty, subject to its terms and applicable consumer rights.

✓ Performance
SP 7-8: 116.7L/min at 36m head; maximum head approximately 50m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.

✓ Operating Flow Limits
For continuous running, keep pump flow between approximately 11.7 and 151.7L/min.
Motor cooling may require more than 11.7L/min, depending on bore diameter and installation.
Do not operate against a closed outlet for more than 30 seconds.

✓ Outlet Connection
40mm (1 1/2") Rp / BSP female thread.
Built-in non-return valve.

✓ Liquid & Sand
Clean, thin, non-aggressive water.
Maximum sand content: 150g/m3.
Liquid temperature: +2 to +40°C.

✓ Starting & Motor Protection
240V single phase, two wire. This version uses a 1.1kW ULTRA RSIR motor with its starting equipment in the motor.

Automatic operation: connect suitable tank-level or pressure controls.
Where water levels could expose the inlet, use dry-running protection to stop the pump before it draws in air.

✓ Installation & Water Levels
Minimum borehole internal diameter: 105mm.
Maximum installation depth is 150m below the water surface.
Keep inlet below the lowest water level reached while pumping.
Keep at least 0.5m of water above the inlet as recommended; greater depth may be needed to maintain adequate inlet pressure.
Vertical installation with motor below pump.
Support with suitable pipework and installation hardware; never suspend by the electrical cable.

✓ Motor Cooling
Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.
Do not run dry.

✓ Construction
Pump and impellers: AISI 304 stainless steel.
Multistage hydraulic design.
Water-lubricated bearings.

✓ Motor & Electrical Supply
SP 7-8 240V two wire ULTRA: Motor ULTRA / RSIR; P2 1.1kW; current 8.6A.
50Hz. Current ratings refer to 240V single-phase or 415V three-phase supply.
Protection settings must match the actual motor nameplate.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.