GRUNDFOS SP 3A-18 BORE PUMP 1.1KW 240V TWO WIRE ULTRA MOTOR

Grundfos SP 3A-18 is a 1.1kW multistage bore pump for clean groundwater supply, irrigation and pressure boosting. Its stainless-steel pump and ULTRA two-wire motor form a complete set for boreholes from 105mm internal diameter. This 240V single-phase version uses two-wire operation.

✓ Rated flow: 3m3/h (50L/min)
✓ Rated head at that flow: 80m
✓ Outlet: 32mm (1 1/4") Rp / BSP female thread
✓ Supply: 240V two wire
✓ Motor output: 1.1kW
✓ Clean water; maximum sand content 50g/m3
✓ Motor: ULTRA RSIR, rated current 8.6A
✓ Minimum borehole internal diameter: 105mm; maximum submergence: 150m

SP 3A Official 50Hz Performance Curve
SP Installation & Operating Instructions

Grundfos SP series submersible bore pump; representative image

Grundfos SP 3A-18 supplies clean groundwater for domestic water systems, irrigation and pressure boosting, with a rated flow of 3m3/h (50L/min) at 80m head. This rated duty describes flow and head together. Actual flow depends on pumping lift, required outlet pressure and pipe resistance; the matching 50Hz curve helps assess expected flow for the installation.

The outlet is 32mm (1 1/4") Rp / BSP female thread. The pump handles clean, thin, non-aggressive water with a maximum sand content of 50g/m3. A built-in non-return valve reduces return flow when the pump stops.

The motor is a 1.1kW ULTRA RSIR unit for 240V single-phase, two-wire operation. Its rated current is 8.6A.

For automatic operation, connect suitable tank-level or pressure controls. Where the water level could fall below the pump inlet, use dry-running protection to stop the pump before it draws in air. Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

Keep the pump inlet submerged below the lowest water level reached while pumping. At least 0.5m of water above the inlet is recommended; greater submergence may be needed to maintain adequate pressure at the inlet. Maximum installation depth is 150m below the water surface. Install vertically with the motor below the pump and support the assembly with suitable pipework and installation hardware. Do not lift or suspend it by its electrical cable.

Liquid temperature is +2 to +40°C.

The pump and impellers are AISI 304 stainless steel. Multiple impeller stages build head through the pump, while water-lubricated bearings support the rotating assembly.

The Australian catalogue specifies a one-year ULTRA motor warranty, subject to its terms and applicable consumer rights.

SP 3A Official 50Hz Performance Curve
SP Installation & Operating Instructions

✓ Warranty
The Australian catalogue specifies a one-year ULTRA motor warranty, subject to its terms and applicable consumer rights.

✓ Performance
SP 3A-18: 50L/min at 80m head; maximum head approximately 115m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.

✓ Operating Flow Limits
For continuous running, keep pump flow between approximately 5 and 65L/min.
Motor cooling may require more than 5L/min, depending on bore diameter and installation.
Do not operate against a closed outlet for more than 30 seconds.

✓ Outlet Connection
32mm (1 1/4") Rp / BSP female thread.
Built-in non-return valve.

✓ Liquid & Sand
Clean, thin, non-aggressive water.
Maximum sand content: 50g/m3.
Liquid temperature: +2 to +40°C.

✓ Starting & Motor Protection
240V single phase, two wire.
Motor: ULTRA RSIR.

Automatic operation: connect suitable tank-level or pressure controls.
Where water levels could expose the inlet, use dry-running protection to stop the pump before it draws in air.

✓ Installation & Water Levels
Minimum borehole internal diameter: 105mm.
Maximum installation depth: 150m below the water surface.
Keep inlet below the lowest water level reached while pumping.
Keep at least 0.5m of water above the inlet as recommended; greater depth may be needed to maintain adequate inlet pressure.
Vertical installation with motor below pump.
Support with suitable pipework and installation hardware; never suspend by the electrical cable.

✓ Construction
Pump and impellers: AISI 304 stainless steel.
Multistage hydraulic design.
Water-lubricated bearings.

✓ Motor & Electrical Supply
SP 3A-18 240V two wire ULTRA: Motor ULTRA RSIR; P2 1.1kW; current 8.6A.
50Hz. Current ratings refer to 240V single-phase or 415V three-phase supply.
Protection settings must match the actual motor nameplate.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.