Grundfos SP series submersible bore pump; representative image
Grundfos SP series submersible bore pump; representative image
Grundfos SP 2A official 50Hz performance chart showing flow against head in metres and pressure in kPa
Grundfos SP 2A official 50Hz performance chart showing flow against head in metres and pressure in kPa
Grundfos SP series submersible bore pump; representative image
Grundfos SP 2A official 50Hz performance chart showing flow against head in metres and pressure in kPa

GRUNDFOS SP 2A SERIES 4" SUBMERSIBLE BORE PUMPS

Grundfos SP 2A multistage bore pumps supply clean groundwater for domestic water systems, irrigation and pressure boosting. Different stage counts provide the head needed to lift water and maintain outlet pressure. The stainless-steel pump and motor sets suit boreholes from 105mm internal diameter, with single-phase two-wire, single-phase three-wire and three-phase motor options.

✓ Rated flow: 2m3/h (33.3L/min)
✓ Rated head at that flow: 24-191m, depending on model
✓ Outlet: 32mm (1 1/4") Rp / BSP female thread
✓ Clean water; maximum sand content 50g/m3
✓ 240V single phase: two-wire internal starting or three-wire external starter
✓ Motor protection: built-in on 0.37-0.75kW single phase; external protection required on 1.1-2.2kW single phase and all three phase
✓ Minimum borehole internal diameter: 105mm
✓ Three-wire SP 2A-6, SP 2A-9, SP 2A-13, SP 2A-18, SP 2A-28 and SP 2A-33: starter included
✓ SP 2A-23 three wire: external starter and current protection required

SP 2A Official 50Hz Performance Curve
SP Installation & Operating Instructions

Grundfos SP series submersible bore pump; representative image

Grundfos SP 2A pumps supply clean groundwater for domestic water systems, irrigation and pressure boosting. Rated flow is 2m3/h (33.3L/min), with rated heads from 24m to 191m across these models. Each head rating is stated at that same rated flow. Actual flow depends on pumping lift, required outlet pressure and pipe resistance; the matching 50Hz curve helps assess expected flow for the installation.

The outlet is 32mm (1 1/4") Rp / BSP female thread. The pump handles clean, thin, non-aggressive water with a maximum sand content of 50g/m3. A built-in non-return valve reduces return flow when the pump stops.

The 240V single-phase two-wire versions have their starting device and thermal protection built into the motor. The 240V single-phase three-wire SP 2A-6, SP 2A-9, SP 2A-13, SP 2A-18, SP 2A-28 and SP 2A-33 packages include a starter. SP 2A-23 requires a matching external starter and current protection.

Single-phase 0.37-0.75kW motors have built-in thermal protection that cuts power if the motor overheats. The 1.1kW single-phase motor also requires external current protection. The 1.5kW and 2.2kW single-phase motors require external motor protection, provided in a suitable starter/control box or as a separate device. All 415V three-phase motors require a motor-protection device that cuts power if the motor overloads. Protection settings must match the motor nameplate.

For automatic operation, connect suitable tank-level or pressure controls. Where the water level could fall below the pump inlet, use dry-running protection to stop the pump before it draws in air. Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

Keep the pump inlet submerged below the lowest water level reached while pumping. At least 0.5m of water above the inlet is recommended; greater submergence may be needed to maintain adequate pressure at the inlet. Maximum installation depth below the water surface is 150m for SP 2A-6 to SP 2A-33 with MS402 motors, and 600m for SP 2A-40 and SP 2A-48 with MS4000 motors. Install vertically with the motor below the pump and support the assembly with suitable pipework and installation hardware. Do not lift or suspend it by its electrical cable.

Liquid temperature is +2 to +40°C. Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor. These pumps are suitable for continuous operation without scheduled cooling stops, provided the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

The pump and impellers are AISI 304 stainless steel. Multiple impeller stages build head through the pump, while water-lubricated bearings support the rotating assembly. MS402 motors have IP68 protection with Class B insulation; MS4000 motors have IP68 protection with Class F insulation.

Two-year limited manufacturer warranty, subject to Grundfos warranty terms and applicable consumer rights.

SP 2A Official 50Hz Performance Curve
SP Installation & Operating Instructions

✓ Warranty
Two-year limited manufacturer warranty, subject to Grundfos warranty terms and applicable consumer rights.

✓ Performance
SP 2A-6: 33.3L/min at 24m head; maximum head approximately 35m.
SP 2A-9: 33.3L/min at 36m head; maximum head approximately 55m.
SP 2A-13: 33.3L/min at 52m head; maximum head approximately 80m.
SP 2A-18: 33.3L/min at 72m head; maximum head approximately 110m.
SP 2A-23: 33.3L/min at 91m head; maximum head approximately 140m.
SP 2A-28: 33.3L/min at 111m head; maximum head approximately 170m.
SP 2A-33: 33.3L/min at 131m head; maximum head approximately 200m.
SP 2A-40: 33.3L/min at 159m head; maximum head approximately 245m.
SP 2A-48: 33.3L/min at 191m head; maximum head approximately 295m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.

✓ Operating Flow Limits
For continuous running, keep pump flow between approximately 3.3 and 43.3L/min.
Motor cooling may require more than 3.3L/min, depending on bore diameter and installation.
Do not operate against a closed outlet for more than 30 seconds.

✓ Outlet Connection
32mm (1 1/4") Rp / BSP female thread.
Built-in non-return valve.

✓ Liquid & Sand
Clean, thin, non-aggressive water.
Maximum sand content: 50g/m3.
Liquid temperature: +2 to +40°C.

✓ Starting & Motor Protection
240V single phase, two wire:
Starting device built into motor.
Built-in thermal protection cuts power if the motor overheats.
Two supply conductors plus protective earth.

240V single phase, three wire:
The 240V single-phase three-wire SP 2A-6, SP 2A-9, SP 2A-13, SP 2A-18, SP 2A-28 and SP 2A-33 packages include a starter. SP 2A-23 requires a matching external starter and current protection.
0.37-0.75kW: built-in thermal protection.
1.1kW: built-in thermal protection plus required external current protection.
1.5kW and 2.2kW: external motor protection required in a suitable starter/control box or separately.
Three motor conductors plus protective earth.

415V three phase:
External motor-protection device required to cut power if the motor overloads.
Use a suitable motor-protective circuit breaker or motor-protection unit with an electrically operated switch.
Match protection settings to the current shown on the motor nameplate.

✓ Automatic Operation & Installation
Automatic operation: connect suitable tank-level or pressure controls.
Where water levels could expose the inlet, use dry-running protection to stop the pump before it draws in air.

✓ Installation & Water Levels
Minimum borehole internal diameter: 105mm.
SP 2A-6 to SP 2A-33, MS402: maximum submergence 150m.
SP 2A-40 and SP 2A-48, MS4000: maximum submergence 600m.
Submergence is measured below the water surface.
Keep inlet below the lowest water level reached while pumping.
Keep at least 0.5m of water above the inlet as recommended; greater depth may be needed to maintain adequate inlet pressure.
Vertical installation with motor below pump.
Support with suitable pipework and installation hardware; never suspend by the electrical cable.

✓ Motor Cooling
Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it.
In a wider bore, the same pump flow moves more slowly around the motor.
Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.
Maximum starts: 100 per hour and 300 per day.
Do not run dry.

✓ Duty
Suitable for continuous operation without scheduled cooling stops, provided the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

✓ Construction
Pump and impellers: AISI 304 stainless steel.
Multistage hydraulic design.
Water-lubricated bearings.

✓ Motor & Electrical Supply
SP 2A-6 240V three wire: Motor MS402; P2 0.37kW; current 3.8A; motor lead 1.7m.
SP 2A-6 415V three phase: Motor MS402; P2 0.37kW; current 1.5A; motor lead 1.7m.
SP 2A-9 240V three wire: Motor MS402; P2 0.37kW; current 3.8A; motor lead 1.7m.
SP 2A-9 240V two wire: Motor MS402; P2 0.37kW; current 3.8A; motor lead 1.7m.
SP 2A-9 415V three phase: Motor MS402; P2 0.37kW; current 1.5A; motor lead 1.7m.
SP 2A-13 240V three wire: Motor MS402; P2 0.55kW; current 5.5A; motor lead 1.7m.
SP 2A-13 240V two wire: Motor MS402; P2 0.55kW; current 5.5A; motor lead 1.7m.
SP 2A-13 415V three phase: Motor MS402; P2 0.55kW; current 2.4A; motor lead 1.7m.
SP 2A-18 240V three wire: Motor MS402; P2 0.75kW; current 7A; motor lead 1.7m.
SP 2A-18 240V two wire: Motor MS402; P2 0.75kW; current 7A; motor lead 1.7m.
SP 2A-18 415V three phase: Motor MS402; P2 0.75kW; current 2.4A; motor lead 1.7m.
SP 2A-23 240V three wire: Motor MS402; P2 1.1kW; current 7.1A; motor lead 1.7m.
SP 2A-23 415V three phase: Motor MS402; P2 1.1kW; current 3.6A; motor lead 1.7m.
SP 2A-28 240V three wire: Motor MS402; P2 1.5kW; current 9.8A; motor lead 1.7m.
SP 2A-28 415V three phase: Motor MS402; P2 1.5kW; current 4.4A; motor lead 1.7m.
SP 2A-33 240V three wire: Motor MS402; P2 1.5kW; current 9.8A; motor lead 1.7m.
SP 2A-33 415V three phase: Motor MS402; P2 1.5kW; current 4.4A; motor lead 1.7m.
SP 2A-40 240V three wire: Motor MS4000; P2 2.2kW; current 15.6A; motor lead 1.7m.
SP 2A-40 415V three phase: Motor MS4000; P2 2.2kW; current 6.3A; motor lead 1.7m.
SP 2A-48 240V three wire: Motor MS4000; P2 2.2kW; current 15.6A; motor lead 1.7m.
SP 2A-48 415V three phase: Motor MS4000; P2 2.2kW; current 6.3A; motor lead 2.5m.

✓ Motor & Electrical Notes
50Hz. Current ratings refer to 240V single-phase or 415V three-phase supply.
Enclosure: IP68. MS402 insulation: Class B. MS4000 insulation: Class F.
Protection settings must match the actual motor nameplate.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

✓ Dimensions & Weight
Dimensions are approximate.

SP 2A-6 240V three wire: Overall length 538.2mm; maximum diameter 101mm; net weight 10.7kg.
SP 2A-6 415V three phase: Overall length 508.2mm; maximum diameter 101mm; net weight 9.4kg.
SP 2A-9 240V three wire: Overall length 601.2mm; maximum diameter 101mm; net weight 11.3kg.
SP 2A-9 240V two wire: Overall length 601.2mm; maximum diameter 101mm; net weight 10.6kg.
SP 2A-9 415V three phase: Overall length 571.2mm; maximum diameter 101mm; net weight 10kg.
SP 2A-13 240V three wire: Overall length 705.2mm; maximum diameter 101mm; net weight 13kg.
SP 2A-13 240V two wire: Overall length 705.2mm; maximum diameter 101mm; net weight 12.3kg.
SP 2A-13 415V three phase: Overall length 671.2mm; maximum diameter 101mm; net weight 11.6kg.
SP 2A-18 240V three wire: Overall length 840.2mm; maximum diameter 101mm; net weight 15.2kg.
SP 2A-18 240V two wire: Overall length 840.2mm; maximum diameter 101mm; net weight 14.5kg.
SP 2A-18 415V three phase: Overall length 810.2mm; maximum diameter 101mm; net weight 14kg.
SP 2A-23 240V three wire: Overall length 985.2mm; maximum diameter 101mm; net weight 17.8kg.
SP 2A-23 415V three phase: Overall length 945.2mm; maximum diameter 101mm; net weight 16.2kg.
SP 2A-28 240V three wire: Overall length 1090.2mm; maximum diameter 101mm; net weight 19.3kg.
SP 2A-28 415V three phase: Overall length 1090.2mm; maximum diameter 101mm; net weight 18.8kg.
SP 2A-33 240V three wire: Overall length 1195.2mm; maximum diameter 101mm; net weight 20.3kg.
SP 2A-33 415V three phase: Overall length 1195.2mm; maximum diameter 101mm; net weight 19.8kg.
SP 2A-40 240V three wire: Overall length 1712.2mm; maximum diameter 101mm; net weight 35kg.
SP 2A-40 415V three phase: Overall length 1492.2mm; maximum diameter 101mm; net weight 31.2kg.
SP 2A-48 240V three wire: Overall length 1880.2mm; maximum diameter 101mm; net weight 39.3kg.
SP 2A-48 415V three phase: Overall length 1660.2mm; maximum diameter 101mm; net weight 34.2kg.

Recently viewed