Grundfos SP 1A multistage bore pumps supply clean groundwater for domestic water supply, irrigation and pressure boosting. Their narrow stainless-steel pump and motor sets suit boreholes from 105mm internal diameter. Different stage counts provide increasing head. Models use 240V single-phase or 415V three-phase motors.

✓ Rated flow: 1m3/h (16.7L/min)
✓ Rated head at that flow: 35-199m, depending on model
✓ Outlet: 32mm (1 1/4") Rp / BSP female thread
✓ Clean water; maximum sand content 50g/m3
✓ 240V single phase, three wire: starter included
✓ 240V single phase, two wire: built-in starter and overheat protection
✓ 415V three phase: requires a protection device that cuts power if the motor overloads
✓ Minimum borehole internal diameter: 105mm

SP 1A Official 50Hz Performance Curve
SP Installation & Operating Instructions

Grundfos SP series submersible bore pump; representative image

Grundfos SP 1A pumps supply clean groundwater for domestic water systems, irrigation and pressure boosting. Rated flow is 1m3/h (16.7L/min), with rated heads from 35m to 199m across these models. Each head rating is stated at that same rated flow; actual flow depends on pumping lift, required outlet pressure and pipe resistance. Use the matching 50Hz curve to assess expected flow for the installation.

The outlet is 32mm (1 1/4") Rp / BSP female thread. These pumps handle clean, thin, non-aggressive water with a maximum sand content of 50g/m3. They are not sewage or solids-handling drainage pumps. A built-in non-return valve reduces return flow when the pump stops.

The 240V single-phase three-wire versions include a starter. The 240V single-phase two-wire version has its starting device built into the motor. Both single-phase types have thermal protection that cuts power if the motor overheats. The 415V three-phase versions require a motor-protection device that cuts power if the motor overloads, with its settings matched to the motor nameplate.

For automatic operation, connect suitable tank-level or pressure controls. Where the water level could fall below the pump inlet, use dry-running protection to stop the pump before it draws in air. Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

Keep the pump inlet submerged below the lowest water level reached while pumping. At least 0.5m of water above the inlet is recommended; greater submergence may be needed to maintain adequate pressure at the inlet. Maximum installation depth is 150m below the water surface. Install vertically with the motor below the pump and support the assembly with suitable pipework and installation hardware. Do not lift or suspend it by its electrical cable.

Liquid temperature is +2 to +40°C. Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it. In a wider bore, the same pump flow moves more slowly around the motor. Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor. SP 1A pumps are suitable for continuous operation without scheduled cooling stops, provided the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

The pump and impellers are AISI 304 stainless steel. Multiple impeller stages build head through the pump, while water-lubricated bearings support the rotating assembly. The Grundfos MS402 submersible motor is rated IP68 with Class B insulation.

Two-year limited manufacturer warranty, subject to Grundfos warranty terms and applicable consumer rights.

SP 1A Official 50Hz Performance Curve
SP Installation & Operating Instructions

✓ Warranty
Two-year limited manufacturer warranty, subject to Grundfos warranty terms and applicable consumer rights.

✓ Performance
SP 1A-9: 16.7L/min at 35m head; maximum head approximately 54m.
SP 1A-14: 16.7L/min at 55m head; maximum head approximately 81m.
SP 1A-18: 16.7L/min at 70m head; maximum head approximately 105m.
SP 1A-21: 16.7L/min at 82m head; maximum head approximately 123m.
SP 1A-28: 16.7L/min at 110m head; maximum head approximately 163m.
SP 1A-42: 16.7L/min at 146m head; maximum head approximately 230m.
SP 1A-50: 16.7L/min at 174m head; maximum head approximately 280m.
SP 1A-57: 16.7L/min at 199m head; maximum head approximately 313m.

Maximum head is at zero flow. Use the performance chart to check flow at your required head.

✓ Operating Flow Limits
For continuous running, keep pump flow between approximately 1.7 and 21.7L/min.
Motor cooling may require more than 1.7L/min, depending on the bore diameter and installation.
Do not operate against a closed outlet for more than 30 seconds.

✓ Outlet Connection
32mm (1 1/4") Rp / BSP female thread.
Built-in non-return valve.

✓ Liquid & Sand
Clean, thin, non-aggressive water.
Maximum sand content: 50g/m3.
Liquid temperature: +2 to +40°C.
Not for sewage, fibres or larger solids.

✓ Starting & Motor Protection
240V single phase, three wire:
Starter included.
Built-in thermal protection cuts power if the motor overheats.
Three motor conductors plus protective earth.

240V single phase, two wire:
Starting device built into the motor.
Built-in thermal protection cuts power if the motor overheats.
Two supply conductors plus protective earth.

415V three phase:
Requires a motor-protection device that cuts power if the motor overloads.
Use a suitable motor-protective circuit breaker or motor-protection unit with an electrically operated switch.
Set the protection to match the current shown on the motor nameplate.

✓ Automatic Operation & Installation
Automatic operation: connect suitable tank-level or pressure controls.
Where water levels could expose the inlet, use dry-running protection to stop the pump before it draws in air.

✓ Installation & Water Levels
Minimum borehole internal diameter: 105mm.
Maximum installation depth: 150m below the water surface.
Keep inlet below the lowest water level reached while pumping.
Keep at least 0.5m of water above the inlet as recommended; greater depth may be needed to maintain adequate inlet pressure.
Vertical installation with motor below pump.
Support with suitable pipework and installation hardware; never suspend by the electrical cable.

✓ Motor Cooling
Water must pass around the outside of the motor at a speed of at least 0.15m/s (15cm/s) to cool it.
In a wider bore, the same pump flow moves more slowly around the motor.
Fit a cooling sleeve if the installation cannot provide the required speed; the sleeve directs water past the motor.
Maximum starts: 100 per hour and 300 per day.
Do not run dry.

✓ Duty
Suitable for continuous operation without scheduled cooling stops, provided the inlet stays submerged and the specified flow, motor cooling and liquid temperature limits are maintained.

✓ Construction
Pump and impellers: AISI 304 stainless steel.
Multistage hydraulic design.
Water-lubricated bearings.

✓ Motor & Electrical Supply
SP 1A-9 240V three wire with starter: P2 0.37kW; current 3.8A; motor lead 1.7m.
SP 1A-9 415V three phase: P2 0.37kW; current 1.5A; motor lead 1.7m.
SP 1A-14 240V three wire with starter: P2 0.37kW; current 3.8A; motor lead 1.7m.
SP 1A-14 415V three phase: P2 0.37kW; current 1.5A; motor lead 1.7m.
SP 1A-18 240V three wire with starter: P2 0.55kW; current 5.5A; motor lead 1.7m.
SP 1A-18 415V three phase: P2 0.55kW; current 2.4A; motor lead 1.7m.
SP 1A-21 240V three wire with starter: P2 0.55kW; current 5.5A; motor lead 1.7m.
SP 1A-21 415V three phase: P2 0.55kW; current 2.4A; motor lead 1.7m.
SP 1A-28 240V two wire: P2 0.75kW; current 7A; motor lead 1.7m.
SP 1A-42 415V three phase: P2 1.1kW; current 3.6A; motor lead 1.7m.
SP 1A-50 415V three phase: P2 1.5kW; current 4.4A; motor lead 2.5m.
SP 1A-57 415V three phase: P2 1.5kW; current 4.4A; motor lead 2.5m.

✓ Motor & Electrical Notes
50Hz. Motor model: Grundfos MS402.
415V figures shown for three-phase models.
Protection settings must match the actual motor nameplate.
Enclosure: IP68. Insulation: Class B.
Extend the motor lead with correctly sized submersible cable and a suitable waterproof cable joint for the installation depth.

✓ Dimensions & Weight
Dimensions are approximate.

SP 1A-9 240V three wire with starter: Overall length 601.2mm; maximum diameter 101mm; net weight 12.2kg.
SP 1A-9 415V three phase: Overall length 571.2mm; maximum diameter 101mm; net weight 10.9kg.
SP 1A-14 240V three wire with starter: Overall length 706.2mm; maximum diameter 101mm; net weight 13.1kg.
SP 1A-14 415V three phase: Overall length 676.2mm; maximum diameter 101mm; net weight 11.8kg.
SP 1A-18 240V three wire with starter: Overall length 810.2mm; maximum diameter 101mm; net weight 14.8kg.
SP 1A-18 415V three phase: Overall length 775.2mm; maximum diameter 101mm; net weight 13.4kg.
SP 1A-21 240V three wire with starter: Overall length 873.2mm; maximum diameter 101mm; net weight 15.4kg.
SP 1A-21 415V three phase: Overall length 838.2mm; maximum diameter 101mm; net weight 14kg.
SP 1A-28 240V two wire: Overall length 1050.2mm; maximum diameter 101mm; net weight 17.2kg.
SP 1A-42 415V three phase: Overall length 1386.2mm; maximum diameter 101mm; net weight 18.5kg.
SP 1A-50 415V three phase: Overall length 1594.2mm; maximum diameter 101mm; net weight 20.8kg.
SP 1A-57 415V three phase: Overall length 1741.2mm; maximum diameter 101mm; net weight 21.9kg.