Pipe HDPE Corrugated SN8, 225mm, 6 Metre
Pipe HDPE Corrugated SN8, 225mm, 6 Metre

CORRUGATED HDPE STORMWATER PIPE

Corrugated HDPE stormwater pipe SN8 supplied in nominal 6 metre straight lengths. For gravity stormwater drainage, civil works, subdivisions and underground site drainage systems.

✓ SN8 Stiffness Class
✓ Suited for Non-Pressure Applications
✓ 6 Metre Nominal Length
✓ Corrugated HDPE Construction
✓ Smooth Internal Bore
✓ O-Ring & Lubricant Available On Request

Prices given on this page are for supply within Western Australia. Please contact us if you require longer coils of this pipe, or if you would like availability and pricing outside WA.

Corrugated HDPE Pipe Brochure
Corrugated HDPE Pipe Backfill - Cement Stabilised
Corrugated HDPE Pipe Backfill - Sand & Coarse Grained Soils
Corrugated HDPE Pipe Jointing Instructions

Pipe HDPE Corrugated SN8, 225mm, 6 Metre

Corrugated HDPE stormwater pipe with an SN8 stiffness class, supplied in nominal 6 metre straight lengths. It is designed for underground gravity stormwater drainage and water-conveyance systems used in civil, subdivision, commercial, industrial and infrastructure projects.

Manufactured from PE100 high-density polyethylene, the pipe has a corrugated external profile for underground strength and a smooth internal bore for efficient drainage flow. SN8 is the pipe’s stiffness class for underground installations, and the pipe is suited to non-pressure applications.

Corrugated HDPE pipe is identified by its nominal diameter. The nominal size may differ from the actual internal diameter, outside diameter and socket dimensions, which can vary between pipe sizes and manufacturers.

Pipe lengths are joined together using O-rings and lubricant, which are available with the pipe at no extra cost upon request. Each length of pipe has a socket for joining to another length of pipe.

Installation requirements should be confirmed for the project conditions, particularly beneath roads, construction equipment, railways or other heavily loaded areas. Installed performance depends on suitable trench preparation, bedding, backfill material, compaction, cover depth and expected external loading.

Prices given on this page are for supply within Western Australia. Please contact us if you require longer coils of this pipe, or if you would like availability and pricing outside WA.

Corrugated HDPE Pipe Brochure
Corrugated HDPE Pipe Backfill - Cement Stabilised
Corrugated HDPE Pipe Backfill - Sand & Coarse Grained Soils
Corrugated HDPE Pipe Jointing Instructions

Nominal Diameter (DN) Outside Diameter (mm) Inside Diameter (mm) Stiffness Class (SN) Jointing Method Approx. Weight (KG)
225 257 223 8 Rubber Ring (RRJ) 22
300 339 294 8 Rubber Ring (RRJ) 38
375 425 371 8 Rubber Ring (RRJ) 55
450 508 438 8 Rubber Ring (RRJ) 83
525 595 514 8 Rubber Ring (RRJ) 110
600 672 591 8 Rubber Ring (RRJ) 146
750 825 731 8 Rubber Ring (RRJ) 222
900 995 869 8 Rubber Ring (RRJ) 253
✓ Product Type
Corrugated HDPE stormwater pipe – SN8, supplied in nominal 6 metre straight lengths.

✓ Function
Designed for underground gravity stormwater and drainage systems. Suited to non-pressure applications.

✓ Nominal Sizing
Pipe is identified by its nominal diameter. The actual internal diameter, outside diameter and socket dimensions may differ from the nominal size and should be confirmed where connection to existing infrastructure is required.

✓ Stiffness Class
SN8 stiffness class for underground installations.

✓ Supplied Length
Nominal 6 metre straight length. Effective installed length is reduced where the pipe enters the adjoining socket and varies according to the pipe size.

✓ Jointing Method
Pipe lengths are joined together using O-rings and lubricant, which are available with the pipe at no extra cost upon request. Each length of pipe has a socket for joining to another length of pipe.

✓ Construction & Material
PE100 High Density Polyethylene (HDPE) with a corrugated external profile and smooth internal bore.

✓ Applications
Gravity stormwater drainage, subdivision and civil drainage, commercial and industrial site drainage and underground water-conveyance systems.

✓ Installation Requirements
Installation requirements should be confirmed for the project conditions, particularly beneath roads, construction equipment, railways or other heavily loaded areas. Installed performance depends on suitable trench preparation, bedding, backfill material, compaction, cover depth and expected external loading.